跳至主要内容
临床试验/NCT01500070
NCT01500070已完成2 期

PREVENT: a Prospective, Multi-center, Monitored Trial Investigating the Implant of the Promus Everolimus-Eluting Stent System in Critically Ischemic Lesions BTK

Flanders Medical Research Program8 个研究点 分布在 3 个国家目标入组 70 人开始时间: 2012年8月1日最近更新:
适应症
干预措施

试验速览

阶段
2 期
状态
已完成
入组人数
70
试验地点
8
主要终点
Primary patency

研究概览

简要总结

This is a single-arm, prospective, multi-center monitored trial recruiting patients with critical limb ischemia and with one or more lesions in the arteries below the knee. The immediate and long-term (up to 12 months) outcome of the PROMUS ELEMENT Everolimus-Eluting Stent System (Boston Scientific) and the PROMUS ELEMENT PLUS Everolimus-Eluting Stent System (Boston Scientific) will be evaluated.

In 2 Belgian centers, 3 German centers and 1 New Zealand center a total of 70 patients will be recruited. Primary endpoint is primary patency at 12 months, defined as absence of restenosis (≥50% stenosis) or occlusion within the originally treated lesion based on angiography.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •General Inclusion Criteria:
  • •Patient presenting with rest pain or minor tissue loss (Rutherford class 4 or 5)
  • •Patient is willing to comply with specified follow-up evaluations at the specified times
  • •Patient is >18 years old
  • •Patient understands the nature of the procedure and provides written informed consent, prior to enrolment in the study
  • •Patient has a projected life-expectancy of at least 12 months
  • •The treating physician consider the patient eligible for below-the-knee treatment with the PROMUS ELEMENT Stent (Boston Scientific) and PROMUS ELEMENT PLUS Stent (Boston Scientific)
  • •Male, infertile female, or female of child bearing potential practicing an acceptable method of birth control with a negative pregnancy test within 7 days prior to study procedure
  • •Angiographic Inclusion Criteria:
  • •Single or multiple lesions with minimally 70% stenosis in one or more infrapopliteal arteries, including the tibiofibular trunk
  • •A maximum of two focal target lesions in one or more infrapopliteal vessels
  • •Length of lesion is maximally 40 mm, allowing maximally 2 planned stents to be implanted
  • •Target vessel diameter visually estimated to be >2.5mm and <4.0mm
  • •Guidewire and delivery system successfully traversed lesion

排除标准

  • •Patient refusing treatment
  • •Previously implanted stent in the artery to be treated
  • •Failed PTA of target lesion/vessel less than 3 months prior to study procedure
  • •The reference segment diameter is not suitable for the available stent design
  • •Untreated flow-limiting inflow lesions
  • •Perioperative unsuccessful ipsilateral percutaneous vascular procedure to treat inflow disease just prior to enrollment
  • •Any previous surgery in the target vessel (including prior ipsilateral crural bypass)
  • •Aneurysm in the target vessel
  • •Patient presents with renal failure, evidenced by a serum creatinine level >2.0mg/dL
  • •Patient presents with platelet levels above or below normal range
  • •Non-atherosclerothic disease resulting in occlusion (e.g. embolism, Buerger's disease, vasculitis)
  • •Severe medical comorbidities (untreated CAD/CHF, severe COPD, metastatic malignancy, dementia, etc) or other medical condition that would preclude compliance with the study protocol or 1-year life expectancy
  • •Major distal amputation (above the transmetatarsal) in the study limb or non-study limb
  • •Septicemia or bacteremia
  • •Any previously known coagulation disorder, including hypercoagulability
  • •Contraindication to anticoagulation or antiplatelet therapy
  • •Known allergies to stent or stent components
  • •Known allergy to contrast media that cannot be adequately pre-medicated prior to the study procedure
  • •Patient with known hypersensitivity to heparin, including those patients who have had a previous incidence of heparin-induced thrombocytopenia (HIT) type II
  • •Currently participating in another clinical research trial
  • •Angiographic evidence of intra-arterial thrombus or atheroembolism from inflow treatment
  • •Target lesion access not performed by transfemoral approach.

研究组 & 干预措施

Drug-eluting stent

Experimental

Patients implanted with the PROMUS ELEMENT Everolimus-Eluting Stent System (Boston Scientific) or the PROMUS ELEMENT PLUS Everolimus-Eluting Stent System (Boston Scientific).

干预措施: Everolimus-Eluting Stent (PROMUS ELEMENT) (Device)

结局指标

主要结局

Primary patency

时间窗: 12 months

Absence of restenosis (50% stenosis) or occlusion within the originally treated lesion based on angiography.

次要结局

  • Technical success(1 day post-procedure)
  • Secondary patency rate(1, 6 and 12 month follow-up)
  • Primary assisted patency rate(1, 6 and 12 month follow-up)
  • Clinical success at follow-up(1 day, 1 month, 6 month and 12 month follow-up)
  • Improvement of ankle-brachial index (ABI)(1 day, 1 month, 6 month and 12 month follow-up)
  • Serious Adverse Events (SAE)(1 day, 1 month, 6 month and 12 month follow-up)
  • Hemodynamic primary patency rate(1, 6 and 12 month follow-up)
  • Limb-salvage(1, 6 and 12 month follow-up)
  • Target lesion revascularization (TLR)(1 day, 1 month, 6 month and 12 month follow-up)

研究者

申办方类型
Network
责任方
Sponsor

研究点 (8)

Loading locations...