Clinical Evaluation of Conventional and 3D-printed Implant-supported Overdentures Retained With New Attachment Systems
试验速览
- 阶段
- 不适用
- 状态
- Enrolling By Invitation
- 入组人数
- 20
- 试验地点
- 1
- 主要终点
- Retention Force of Implant Overdentures (IODs)
研究概览
简要总结
Randomized Crossover Clinical Trial Comparing Two Denture Designs (A and B) Retained by Two Locator Systems (ST and EMI) in Implant Overdenture Patients
详细描述
This randomized crossover clinical trial evaluates patient-reported outcomes and clinical performance of implant overdentures (IODs) using two different denture designs (A and B) retained by two locator attachment systems: Locator ST and Locator EMI. Each participant will receive both denture designs in a crossover sequence, allowing direct within-subject comparison.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Crossover
- 主要目的
- Health Services Research
- 盲法
- None
入排标准
- 年龄范围
- — 至 70 Years(Child, Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Completely edentulous patients
- •Non-smokers
- •Patients free from intra-oral diseases that may affect implant-overdenture prognosis
- •Patients free from systemic conditions that may influence bone resorption or implant success
- •Able and willing to comply with study visits and follow-up schedule
排除标准
- •Smokers or tobacco users
- •Presence of active oral lesions, infections, or mucosal pathology
- •Systemic diseases affecting bone metabolism (e.g., uncontrolled diabetes, osteoporosis requiring bisphosphonates)
- •History of head and neck radiation
- •Severe parafunctional habits (e.g., bruxism)
- •Inability to attend follow-up appointments or provide informed consent
研究组 & 干预措施
Arm 1: Denture A with Locator ST Participants receive Denture A retained by Locator ST attachments.
Participants receive Denture A retained by Locator ST attachments.
干预措施: Crossover Assignment (Other)
Denture A with Locator EMI
Participants receive Denture A retained by two Locator EMI attachments. Same outcome measures as above, allowing comparison of attachment type influence on patient-reported and clinical outcomes.
干预措施: Crossover Assignment (Other)
结局指标
主要结局
Retention Force of Implant Overdentures (IODs)
时间窗: Outcome measures were assessed at four clearly defined time points: 1. Baseline (Immediately after overdenture pick up) 2. 3 month follow up 3. 6 month follow up 4. 9 month follow up These time points correspond to the evaluation of implant overdentures
Retention force measured using a digital force gauge to quantify the dislodgement force required to remove the overdenture from the implants. Measurements will be reported in Newtons (N).
Denture Wear of Implant Overdentures (IODs)
时间窗: Wear was evaluated relative to the baseline measurement taken immediately after pick-up, with follow-up assessment 9-month per denture type: 1. 3 month follow up 2. 6 month follow up 3. 9 month follow up
Denture wear assessed by measuring surface loss on occlusal surface using digital analysis. Wear depth recorded in millimeters (mm) at each evaluation point.
Peri-implant Soft Tissue Health (Modified Plaque Index and Modified Bleeding Index Scores)
时间窗: Assessments performed over an 18-month total follow-up period, at the following intervals: 1 - Immediately after pick-up (baseline) 2 - 3 months 3 - 6 months 4 - 9 months 5 - 12 months 6 - 15 months 7 - 18 months
Peri-implant soft tissue health assessed using the Modified Plaque Index (mPI) and Modified Bleeding Index (mBI). Both indices are ordinal clinical scales scored according to standard peri-implant evaluation criteria: mPI range: 0-3 0 = no plaque 3 = abundant plaque mBI range: 0-3 0 = no bleeding 3 = profuse bleeding Interpretation: Higher scores indicate worse peri-implant soft tissue health. Unit of Measure: Ordinal index scores (mPI, mBI)
Crestal bone level changes
时间窗: Radiographic measurements performed over an 18-month total follow-up period, at the following intervals: 1 - Immediately after pick-up (baseline) 2 - 3 months 3 - 6 months 4 - 9 months 5 - 12 months 6 - 15 months 7 - 18 months
Crestal bone levels measured on standardized periapical radiographs taken with a paralleling technique. Bone level is defined as the distance from the implant shoulder to the first bone-to-implant contact.
Oral Health-Related Quality of Life (OHIP-19 score)
时间窗: OHIP-19 scores recorded three times during each 9-month denture phase: 1 -Before pick-up 2 - Immediately after pick-up 3 - At 9 months follow up
Oral health-related quality of life assessed using the Oral Health Impact Profile-19 (OHIP-19) questionnaire. The OHIP-19 consists of 19 items, each scored on a 5-point ordinal scale from 0 to 4: 0 = never 4 = very often Minimum score: 0 Maximum score: 76 Interpretation: Higher scores indicate worse oral health-related quality of life.
Patient Satisfaction (Visual Analog Scale Score)
时间窗: VAS satisfaction scores recorded three times during each 9-month denture phase: 1 - Before pick-up 2 - Immediately after pick-up 3 - At 9 months follow up
Patient satisfaction with the denture and attachment system measured using a 10-point Visual Analog Scale (VAS). Participants rated their satisfaction on a scale from 0 to 10: 0 = completely dissatisfied 10 = completely satisfied
次要结局
未报告次要终点
研究者
Mohamed Moustafa
Professor
Al-Azhar University