Optical Coherence Tomography for Drug Eluting Stent Safety
- Conditions
- Coronary Artery Disease
- Interventions
- Device: sirolimus drug eluting coronary stent Cypher™ (Cordis Corp, Johnson & Johnson Co)Device: paclitaxel polymer drug eluting stent Taxus Libertè™ (Boston Scientific, Natick MS)Device: zotarolimus drug eluting coronary stent Endeavor™ (Medtronic, Santa Rosa, CA)Device: Libertè bare metal coronary stent Libertè™ BMS(Boston Scientific, Natick, MS)
- Registration Number
- NCT00693030
- Lead Sponsor
- A.O. Ospedale Papa Giovanni XXIII
- Brief Summary
Increasing lesion complexity in percutaneous coronary interventions (PCI) has warranted the use of overlapping drug-eluting stents. Whether the substantial impairment of arterial healing observed at sites of overlap in preclinical pathologic studies persists in patients undergoing PCI is unknown. Consecutive patients with long lesions in native coronary vessels requiring stents in overlap are prospectively randomized to receive multiple sirolimus-,paclitaxel polymer-or zotarolimus eluting stents versus bare metal stents. The completeness of stent struts coverage and/or late malapposition are evaluated by Optical Coherence Tomography at 6 months follow-up
- Detailed Description
If overlapping drug-eluting stents provide increased vessel toxicity is not known. Given the association of delayed healing and incomplete endothelialization observed in animal and human autopsy studies at overlapping sites it is unclear why most patients do well with multiple DES implanted. OCT detecs smaller degrees of in-stent neointima more accurately than IVUS and might be a useful method for identify strut coverage and/or malapposition.
Patients if eligible on the basis of clinical and angiographic criteria, are randomized (2:2:2:1) to receive multiple TAXUS Libertè™ vs Cypher Select™ vs Endeavor™ vs Libertè BM stents, in overlap. Stent implantation are done accordingly to the normal interventional practice. QCA and IVUS are performed at the end of optimal stents placement per visual judgement (residual stenosis \< 10%, TIMI 3 flow). Stent, lumen size and volume as well as complete stent strut apposal will be determined by IVUS analysis. Clinical follow-up will take place at 1 month (±1 week), 6 months (±2 weeks) and 1 year (±2 weeks). At 6-months follow-up all patients will undergo a quantitative coronary angiography (QCA), IVUS and Optical Coherence Tomography (LightLab OCT Imaging M2, automated pull back and flushing combination)assessments.
OCT images will be acquired at 15-30 frames per second. Blind corelab quantitative strut by strut analysis will be performed using a novel dedicated software at each 0.5 mm section. The following OCT variables will be evaluated:number of visualized strut per section, mean-max neointimal thickness per section, % struts well apposed with neointima at overlapping vs non overlapping sites, % struts without neointima, % struts malapposed, rate of \> 30% uncovered struts/total number of struts per section.
Recruitment & Eligibility
- Status
- UNKNOWN
- Sex
- All
- Target Recruitment
- 77
- Native coronary artery disease with ≥ 75% diameter stenosis
- Lesion length ≥ 20 mm,
- Vessel size in between 2.5 and 3.5 mm.
- Multiple, overlapped DES vs BMS placement (intention to overlap ≥ 4 mm)
- Signed patient informed consent
- left main coronary artery disease,
- lesions in coronary artery bypass grafts,
- acute myocardial infarction,
- poor cardiac function as defined by left ventricular global ejection fraction ≤ 30%.
- allergy to aspirin and or clopidogrel/ticlo,
- renal failure with creatinine value > 2.5,
- no suitable anatomy for OCT scan
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- PARALLEL
- Arm && Interventions
Group Intervention Description 1 sirolimus drug eluting coronary stent Cypher™ (Cordis Corp, Johnson & Johnson Co) Device, Sirolimus drug-eluting stents implanted in overlap 2 paclitaxel polymer drug eluting stent Taxus Libertè™ (Boston Scientific, Natick MS) Device, paclitaxel polymer drug eluting stent 3 zotarolimus drug eluting coronary stent Endeavor™ (Medtronic, Santa Rosa, CA) Device, zotarolimus drug eluting stent 4 Libertè bare metal coronary stent Libertè™ BMS(Boston Scientific, Natick, MS) bare metal coronary stents
- Primary Outcome Measures
Name Time Method Number of uncovered and/or malapposed stent struts at overlapping versus non overlapping sites in drug eluting vs bare metal stents 6 months
- Secondary Outcome Measures
Name Time Method Ischemia Driven Target Vessel Failure 12 months Number of uncovered and/or malapposed stent struts at overlapping sites in sirolimus-, paclitaxel- or zotarolimus eluting stents 6 months
Trial Locations
- Locations (1)
Cardiovascular Department Ospedali Riuniti di Bergamo
🇮🇹Bergamo, Italy