Tandem Polyurethane Stents Compared to Single Silicone Stent for Malignant Ureteral Obstruction
试验速览
- 阶段
- 不适用
- 状态
- 招募中
- 入组人数
- 106
- 试验地点
- 3
- 主要终点
- stent failure rate
研究概览
简要总结
Malignant ureteral obstruction (MUO) is an extrinsic ureteral obstruction caused by malignant diseases. This study aim to compare tandem 6 Fr Percuflex™ stents and single large-caliber 8Fr silicone stent in patients with MUO. The primary endpoint is stent failure rate. The secondary endpoints are patient comfort, quality of life and overall survival.
详细描述
Malignant ureteral obstruction (MUO) is an extrinsic ureteral obstruction caused by malignant diseases. MUO may induce renal failure, which would be a barrier to several therapies including chemotherapy. Indwelling double-pigtail polymeric ureteral stent is a common method to release renal obstruction, but does not necessarily guarantee renal decompression as most studies reported stent failure with a mean of 30% at a mean time of three months [1-3]. Various endoscopic strategies have been proposed to increase time to failure, including tandem polymeric stents, metallic spiral coil stent, self-expanding Nitinol stent and polymeric stents with different lumen diameter and stiffness [4-7]. However, heterogeneity of MUO, low number of patients, unspecified polymer type, retrospective studies and the lack of a standard method to assess stent failure limit robust comparative analysis.
Tandem ureteral stents (TUS) technique uses two polymeric ureteral stents passed simultaneously to better withstand the presumed compressive forces that overcome conventional single stent. This method offers an additional parallel lumen and allows more extraluminal flow between the two stents [6].
In a study on TUS in 39 renal units with MUO, two 6 Fr stents were inserted. Stent failure, defined by flank pain with increasing creatinine level or worsening hydronephrosis during 3 months after stents insertion, was occurred in 4% of cases [7]. This low failure rate compares favorably with the reported rates with single 6Fr polymeric stent or metallic stent. However, stents irritation, defined by profound lower urinary tract symptoms or renal colic in the absence of worsening hydronephrosis or infection, was reported in 29-85% of patients [7,8].
Silicon stent, which is considered biocompatible and soft, has the potential to be less irritative. In a recent systematic review, silicone stents has less stent-related symptoms in comparison to non-silicone polymers and ''hard'' stents. [9]. However, silicone has high susceptibility to compression, which in case of MUO may results in lower drainage efficacy.
This study aim to compare tandem 6 Fr Percuflex™ stents and single large-caliber 8Fr silicone stent in patients with MUO. The primary endpoint is stent failure rate. The secondary endpoints are patient comfort, quality of life and overall survival.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Treatment
- 盲法
- Triple (Participant, Investigator, Outcomes Assessor)
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •patient with malignant ureteral obstruction
排除标准
- •ureteral obstruction of other causes
- •Language comprehension or other limitation in giving informed consent
结局指标
主要结局
stent failure rate
时间窗: 1 year
Failure will be defined when two of the following three appear: renal colic, rise in serum creatinine, hydronephrosis
次要结局
- overall survival(1 year)
- quality of life score(1 year)
- overall survival(1 year)
研究者
Michael Frumer
Urologist
Rabin Medical Center
