跳至主要内容
临床试验/NCT05992363
NCT05992363招募中不适用

Tandem Polyurethane Stents Compared to Single Silicone Stent for Malignant Ureteral Obstruction

Rabin Medical Center3 个研究点 分布在 1 个国家目标入组 106 人开始时间: 2023年12月20日最近更新:
适应症

试验速览

阶段
不适用
状态
招募中
入组人数
106
试验地点
3
主要终点
stent failure rate

研究概览

简要总结

Malignant ureteral obstruction (MUO) is an extrinsic ureteral obstruction caused by malignant diseases. This study aim to compare tandem 6 Fr Percuflex™ stents and single large-caliber 8Fr silicone stent in patients with MUO. The primary endpoint is stent failure rate. The secondary endpoints are patient comfort, quality of life and overall survival.

详细描述

Malignant ureteral obstruction (MUO) is an extrinsic ureteral obstruction caused by malignant diseases. MUO may induce renal failure, which would be a barrier to several therapies including chemotherapy. Indwelling double-pigtail polymeric ureteral stent is a common method to release renal obstruction, but does not necessarily guarantee renal decompression as most studies reported stent failure with a mean of 30% at a mean time of three months [1-3]. Various endoscopic strategies have been proposed to increase time to failure, including tandem polymeric stents, metallic spiral coil stent, self-expanding Nitinol stent and polymeric stents with different lumen diameter and stiffness [4-7]. However, heterogeneity of MUO, low number of patients, unspecified polymer type, retrospective studies and the lack of a standard method to assess stent failure limit robust comparative analysis.

Tandem ureteral stents (TUS) technique uses two polymeric ureteral stents passed simultaneously to better withstand the presumed compressive forces that overcome conventional single stent. This method offers an additional parallel lumen and allows more extraluminal flow between the two stents [6].

In a study on TUS in 39 renal units with MUO, two 6 Fr stents were inserted. Stent failure, defined by flank pain with increasing creatinine level or worsening hydronephrosis during 3 months after stents insertion, was occurred in 4% of cases [7]. This low failure rate compares favorably with the reported rates with single 6Fr polymeric stent or metallic stent. However, stents irritation, defined by profound lower urinary tract symptoms or renal colic in the absence of worsening hydronephrosis or infection, was reported in 29-85% of patients [7,8].

Silicon stent, which is considered biocompatible and soft, has the potential to be less irritative. In a recent systematic review, silicone stents has less stent-related symptoms in comparison to non-silicone polymers and ''hard'' stents. [9]. However, silicone has high susceptibility to compression, which in case of MUO may results in lower drainage efficacy.

This study aim to compare tandem 6 Fr Percuflex™ stents and single large-caliber 8Fr silicone stent in patients with MUO. The primary endpoint is stent failure rate. The secondary endpoints are patient comfort, quality of life and overall survival.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Triple (Participant, Investigator, Outcomes Assessor)

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • patient with malignant ureteral obstruction

排除标准

  • ureteral obstruction of other causes
  • Language comprehension or other limitation in giving informed consent

结局指标

主要结局

stent failure rate

时间窗: 1 year

Failure will be defined when two of the following three appear: renal colic, rise in serum creatinine, hydronephrosis

次要结局

  • overall survival(1 year)
  • quality of life score(1 year)
  • overall survival(1 year)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Michael Frumer

Urologist

Rabin Medical Center

研究点 (3)

Loading locations...

相似试验