MedPath

Tandem Polyurethane Stents Compared to Single Silicone Stent for Malignant Ureteral Obstruction

Phase 3
Not yet recruiting
Conditions
Hydronephrosis; Obstruction, Ureter
Malignancy
Ureter Obstruction
Ureter Stricture
Renal Failure
Interventions
Device: ureteral stent\s insertion
Registration Number
NCT05992363
Lead Sponsor
Rabin Medical Center
Brief Summary

Malignant ureteral obstruction (MUO) is an extrinsic ureteral obstruction caused by malignant diseases. This study aim to compare tandem 6 Fr Percuflex™ stents and single large-caliber 8Fr silicone stent in patients with MUO. The primary endpoint is stent failure rate. The secondary endpoints are patient comfort, quality of life and overall survival.

Detailed Description

Malignant ureteral obstruction (MUO) is an extrinsic ureteral obstruction caused by malignant diseases. MUO may induce renal failure, which would be a barrier to several therapies including chemotherapy. Indwelling double-pigtail polymeric ureteral stent is a common method to release renal obstruction, but does not necessarily guarantee renal decompression as most studies reported stent failure with a mean of 30% at a mean time of three months \[1-3\]. Various endoscopic strategies have been proposed to increase time to failure, including tandem polymeric stents, metallic spiral coil stent, self-expanding Nitinol stent and polymeric stents with different lumen diameter and stiffness \[4-7\]. However, heterogeneity of MUO, low number of patients, unspecified polymer type, retrospective studies and the lack of a standard method to assess stent failure limit robust comparative analysis.

Tandem ureteral stents (TUS) technique uses two polymeric ureteral stents passed simultaneously to better withstand the presumed compressive forces that overcome conventional single stent. This method offers an additional parallel lumen and allows more extraluminal flow between the two stents \[6\].

In a study on TUS in 39 renal units with MUO, two 6 Fr stents were inserted. Stent failure, defined by flank pain with increasing creatinine level or worsening hydronephrosis during 3 months after stents insertion, was occurred in 4% of cases \[7\]. This low failure rate compares favorably with the reported rates with single 6Fr polymeric stent or metallic stent. However, stents irritation, defined by profound lower urinary tract symptoms or renal colic in the absence of worsening hydronephrosis or infection, was reported in 29-85% of patients \[7,8\].

Silicon stent, which is considered biocompatible and soft, has the potential to be less irritative. In a recent systematic review, silicone stents has less stent-related symptoms in comparison to non-silicone polymers and ''hard'' stents. \[9\]. However, silicone has high susceptibility to compression, which in case of MUO may results in lower drainage efficacy.

This study aim to compare tandem 6 Fr Percuflex™ stents and single large-caliber 8Fr silicone stent in patients with MUO. The primary endpoint is stent failure rate. The secondary endpoints are patient comfort, quality of life and overall survival.

References:

1. Docimo SG, Dewolf WC. High failure rate of indwelling ureteral stents in patients with extrinsic obstruction: experience at 2 institutions. J Urol. 1989;142(2 Pt 1):277-279. doi:10.1016/s0022-5347(17)38729-3

2. Vogt B, Blanchet LH. Analysis of Ureteral Tumour Stents for Malignant Ureteral Obstruction: Towards Reshaping an Optimal Stent. Res Rep Urol. 2021;13:773-782. Published 2021 Oct 27. doi:10.2147/RRU.S334277

3. Chung SY, Stein RJ, Landsittel D, et al. 15-year experience with the management of extrinsic ureteral obstruction with indwelling ureteral stents. J Urol. 2004;172(2):592-595. doi:10.1097/01.ju.0000130510.28768.f5

4. Patel C, Loughran D, Jones R, Abdulmajed M, Shergill I. The resonance® metallic ureteric stent in the treatment of chronic ureteric obstruction: a safety and efficacy analysis from a contemporary clinical series. BMC Urol. 2017;17(1):16. Published 2017 Mar 10. doi:10.1186/s12894-017-0204-8

5. Khoo CC, Ho C, Palaniappan V, et al. Single-Center Experience with Three Metallic Ureteral Stents (Allium® URS, Memokath™-051, and Resonance®) for Chronic Ureteral Obstruction. J Endourol. 2021;35(12):1829-1837. doi:10.1089/end.2021.0208

6. Fromer DL, Shabsigh A, Benson MC, Gupta M. Simultaneous multiple double pigtail stents for malignant ureteral obstruction. Urology. 2002;59(4):594-596. doi:10.1016/s0090-4295(01)01646-7

7. Elsamra SE, Motato H, Moreira DM, et al. Tandem ureteral stents for the decompression of malignant and benign obstructive uropathy. J Endourol. 2013;27(10):1297-1302. doi:10.1089/end.2013.0281

8. Shvero A, Haifler M, Mahmud H, Dotan Z, Winkler H, Kleinmann N. Quality of life with tandem ureteral stents compared to percutaneous nephrostomy for malignant ureteral obstruction. Support Care Cancer. 2022;30(11):9541-9548. doi:10.1007/s00520-022-07354-2

9. Boeykens M, Keller EX, Bosio A, et al. Impact of Ureteral Stent Material on Stent-related Symptoms: A Systematic Review of the Literature. Eur Urol Open Sci. 2022;45:108-117. Published 2022 Oct 19. doi:10.1016/j.euros.2022.09.005

Recruitment & Eligibility

Status
NOT_YET_RECRUITING
Sex
All
Target Recruitment
106
Inclusion Criteria
  • patient with malignant ureteral obstruction
Exclusion Criteria
  • ureteral obstruction of other causes
  • Language comprehension or other limitation in giving informed consent

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
Tandem polyurethane stentsureteral stent\s insertionpatients with malignant ureteral obstruction that was treated by tandem 6 Fr Percuflex™ stents
single silicone stentureteral stent\s insertionpatients with malignant ureteral obstruction that was treated by single large-caliber 8-12Fr silicone stent
Primary Outcome Measures
NameTimeMethod
stent failure rate1 year

Failure will be defined when two of the following three appear: renal colic, rise in serum creatinine, hydronephrosis

Secondary Outcome Measures
NameTimeMethod
overall survival1 year

overall survival

quality of life1 year

using the Ureteral stent symptom questionnaire (USSQ) score

Trial Locations

Locations (2)

Sheba medical center

🇮🇱

Ramat Gan, Israel

Rabin Medical Center

🇮🇱

Petah Tikva, Israel

© Copyright 2025. All Rights Reserved by MedPath