MedPath

Effects of High Intensity Laser on Mechanical and Physiological Findings in Pregnant Women With Carpal Tunnel Syndrome

Not Applicable
Completed
Conditions
Carpal Tunnel Syndrome
Pregnancy Related
Interventions
Device: High intensity laser therapy
Other: Conventional Physical Therapy
Registration Number
NCT04969393
Lead Sponsor
October 6 University
Brief Summary

This study will propose a novel approach to treat pregnant women with mild to moderate carpal tunnel syndrome (CTS) using the recently introduced High intensity laser therapy with its deep penetration and high-power characteristics. It's hopeful that the results of this study can fill the gap of knowledge surrounding the conservative treatment options for CTS in order to help patients restore their nerve function properly and promote new ways of addressing CTS.

Detailed Description

Not available

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
54
Inclusion Criteria

(1) Pregnant women with mild to moderate CTS diagnosed by a physician according to the American Association of Electrodiagnostic recent guidelines [18] (2) The age ranged between 20 to 40 years (3) Had positive clinical provocative tests for the CTS (Tinel test and Phalen test) and (5) Had a history of pain, paresthesia or numbness in the median nerve distribution, nocturnal pain, and night waking

Exclusion Criteria

Patients were excluded from the study if they had cervical disc prolapse, cervical spondylosis, thoracic outlet syndrome, diabetes, gestational diabetes, cardiovascular disorders and hypertension. Patients who had carpal tunnel release surgery and patients who were diagnosed with CTS before pregnancy were also excluded from the study.

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
Group A (High Intensity Laser therapy + Conventional Physical Therapy)High intensity laser therapyPatients in group (A) received conventional physical therapy program along with HILT. Patients received pulsed Nd: YAG laser treatment, produced by EXAND MY 1064 nm Laser system, Mectronic Medicale, Italy. The apparatus provided pulsed emission (1064 nm), very high peak power (3 kW), a high level of fluency (energy density; 360-1780 mJ/cm2).
Group A (High Intensity Laser therapy + Conventional Physical Therapy)Conventional Physical TherapyPatients in group (A) received conventional physical therapy program along with HILT. Patients received pulsed Nd: YAG laser treatment, produced by EXAND MY 1064 nm Laser system, Mectronic Medicale, Italy. The apparatus provided pulsed emission (1064 nm), very high peak power (3 kW), a high level of fluency (energy density; 360-1780 mJ/cm2).
Group B (Conventional Physical Therapy)Conventional Physical TherapyPatients in this group received the conventional physical therapy program in the form of splinting, tendon and neural gliding exercises. Patients were instructed to wear a neutral custom volar splint at night and while performing strenuous activities during the day for 5 weeks.Also, the patients performed nerve-and tendon-gliding exercise under direct supervision of the therapist during the treatment sessions. Each exercise was repeated 10 times at each session and patients were encouraged to apply exercise 3-5 times per day for 5 weeks.
Primary Outcome Measures
NameTimeMethod
Changes in Distal latency of median nerve sensory distal latencyBaseline and after 5 Weeks

The Median sensory nerve (SNDL) distal latency was measured according to the American Association of Electrodiagnostic Medicine (AAEM) guidelines with a Neuropack S1 MEB-9004 Nihon Koden (Japan). All measurements were performed in a room with the temperature kept at 25C.

Changes in Distal latency of median nerve motor distal latencyBaseline and after 5 Weeks

The Median motor nerve (MNDL) distal latency was measured according to the American Association of Electrodiagnostic Medicine (AAEM) guidelines with a Neuropack S1 MEB-9004 Nihon Koden (Japan). All measurements were performed in a room with the temperature kept at 25C.

Secondary Outcome Measures
NameTimeMethod
Changes in hand grip strengthBaseline and after 5 Weeks

The hand grip strength (measured in Kilograms) was evaluated by the same investigator. Grip strength was tested by using Jamar hand held dynamometer following the American Society of Hand Therapists guidelines. The patient's arm was positioned with the shoulder adducted and neutrally rotated, the elbow was flexed at 90, the forearm and wrist were neutrally positioned while the participant was sitting. Patients were instructed to squeeze the handle as hard as they could, do maximal grip contraction for 2-5 s.

Changes in numeric pain rating scale (NPRS)Baseline and after 5 Weeks

An 11-point Numerical Pain Rating Scale (NPRS; 0 = no pain, 10 = maximum pain) was used to assess the patients' levels of hand pain pre and post treatment.

Trial Locations

Locations (1)

October 6 University Hospital

🇪🇬

Al Ḩayy Ath Thāmin, Giza, Egypt

© Copyright 2025. All Rights Reserved by MedPath