简要总结

The EUM (electrical uterine myography) (OB Tools, Israel) was tested and found to be reliable as a non-invasive method for evaluating uterine contractions and the fetal heart rate. It is safe and effective in monitoring uterine contractions. The investigators propose to perform a study to validate the accuracy and clinical usefulness of the EUM device by simultaneously monitoring obese patients with current method of external tocodynamometry with the EUM device. Providers will be blinded to the results of the EUM device. Caregivers will continue care as per current guidelines using the information obtained from the current monitoring methods. Information obtained from the EUM devices will not be used to determine the clinical course of action.

详细描述

Purpose:

The investigators propose to perform a study to validate the accuracy and clinical usefulness of the EUM device by comparing it with simultaneous use of current methods (external tocodynamometry) among obese patients.

Objective

Compare the interpretability of the contractions recorded using the EUM device vs. those obtained from external tocodynamometer among obese pregnant women.

研究设计

研究类型
Observational
观察模型
Case Crossover
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
Female
接受健康志愿者

入选标准

  • Maternal age >18 years old
  • Singleton pregnancy
  • Gestational age of 24 completed weeks or greater based on the estimated due date as calculated from last menstrual period or early ultrasound
  • Category I (reassuring) fetal heart rate tracing at time of enrollment

排除标准

  • Fetal anomaly or chromosome defect
  • Allergy to silver
  • Woman with implanted electronic device of any kind
  • Irritated skin or open wound on the abdominal wall

结局指标

主要结局

Continuity in Readings of Contractions

时间窗: within 4 hours of device application

Continuity in readings of contractions, as measured in the number of minutes without a readable tracing in a sample tracing, between the novel EUM device and the external tocodynamometer (standard care) were assessed in pregnant preterm patients. An uninterpretable tracing was defined as any contraction, or any period of contractions, with unclear/uninterpretable baseline, peak onset/timing, height/peak, or duration of contraction.

Continuity in Readings of Fetal Heart Rate

时间窗: within 4 hours of device application

Continuity in Fetal Heart rate readings, as measured by the number of minutes without a readable tracing in a sample tracing between the novel EUM/EMG device and the external tocodynamometer (standard care) will be assessed in pregnant preterm patients. An uninterpretable tracing is defined as any period of fetal heart rate tracing with unclear/uninterpretable baseline, variability, onset/timing, peak, frequency, or duration of accelerations/decelerations

次要结局

未报告次要终点