MedPath

Electrical Stimulation for the Treatment of Optic Neuropathies

Not Applicable
Recruiting
Conditions
Glaucoma
Glaucoma, Open-Angle
Optic Nerve Diseases
Interventions
Device: Repetitive, Transorbital Alternating Current Stimulation (rtACS)
Registration Number
NCT05626426
Lead Sponsor
Stanford University
Brief Summary

The overall aim of this study is to see whether long-term electrical stimulation with a home-stimulation device works well and is safe for the treatment of open-angle glaucoma. Open-Angle Glaucoma is a disease where the nerves in the back of your eye die off faster than expected regardless of your eye pressure.

Detailed Description

This is a concurrent open-label study for patients who are deemed safe to participate in the electrical stimulation trial but do not fit the exact criteria for the randomized clinical trial.

Recruitment & Eligibility

Status
RECRUITING
Sex
All
Target Recruitment
20
Inclusion Criteria
  1. Participant must be at least 18.
  2. Participant must has the ability to comply with the requirements of the study and complete the schedule of events (SOE).
  3. Participant's clinical diagnosis must be consistent with glaucoma characterized by the following features: Mean deviation (MD) worse than -3 on Humphrey Visual Field 24-2 testing. Reliable visual field measures, fixation losses do not exceed 20% and false postivies do not exeed 20%.
  4. In the opinion of the investigator the participant's eye pressure must be clinically stable.
  5. If a participant has two eyes meeting study criteria, the worse eye as determined by mean deviation. If both eyes qualify and have the same MD, the patient may choose which eye they are willing to enter, or else a randomization procedure will assign one eye to the study.
  6. Participant must understand and sign the informed consent. If the participant's vision is impaired to the point where he/she cannot read the informed consent document, the document will be read to the participant in its entirety.
Exclusion Criteria
  1. Participant is unable to comply with study procedures or follow-up visits.
  2. Participant has a history of ocular herpes zoster.
  3. Participant has pathological nystagmus
  4. Participant has evidence of visually significant retinopathy including but not limited to Diabetic retinopathy or retinitis pigmentosa.
  5. Participant has evidence of corneal opacification or lack of optical clarity.
  6. Participant has uveitis or other ocular inflammatory disease.
  7. Participant has any electric or electroinc implants such as a pacemaker.
  8. Participant has acute conjunctivitis.
  9. Participant has acute autoimmune disease.
  10. Participant is pregnant or lactating.
  11. Participant has, in the opinion of the investigator, any physical or mental condition that would increase the risk of participation in the study or may interfere with the study procedures, evaluations and outcome assessments. Including but not limited to all forms of dementia.
  12. Unresected brain tumors
  13. Implanted intracranial magnetic metals (metallic implants in the head / skull such as clamps, coils, ventriculo-peritoneal shunts, endoprostheses, etc.), which are not MRI-compatible. Note: metallic dental implants and titanium screws or plates are acceptable
  14. Patients with any skin damage.
  15. Children and comatose patients.
  16. Patients with history of epileptic seizure within the last 10 years.
  17. Patients with uncontrolled systemic hypertension or uncontrolled diabetes.
  18. Participant is not able to travel, to comply with the requirements of the study or not willing to complete the schedule of events (SOE) and/or unable to confirm follow-up participation
  19. Prior participation in a vision training/stimulation study in the last 12 months

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
Active SASmRepetitive, Transorbital Alternating Current Stimulation (rtACS)Patients will receive active treatment with the device every other day over 8 weeks.
Primary Outcome Measures
NameTimeMethod
Change from baseline in visual field assessed by Humphrey Visual Field Index (VFI).Baseline through 6 months
Change from baseline in visual field assessed by Humphrey Mean Deviation (MD).Baseline through 6 months
Secondary Outcome Measures
NameTimeMethod
Change from baseline in ganglion cell layer as measured by optical coherence tomography (OCT, visible light and/or infrared).Baseline through 6 months
Change from baseline in nerve fiber layer thickness as measured by optical coherence tomography (OCT, visible light and/or infrared).Baseline through 6 months
Change from baseline in visual acuity as assessed by the Snellen visual acuity test.Baseline through Month 6

The Snellen test is a standard eye chart test used to test eyesight.

Change from baseline in visual evoked potential.Baseline through Month 6
Change from baseline in retinal metabolic analysis(RMA)/OcuMet imaging.Baseline through Month 6

There are two index measures of retinal metabolism and a normative database; change from baseline with a statistically significant difference from test-retest variability will be the exploratory endpoint measured here.

Change from baseline in adaptive optics retinal imaging.Baseline through Month 6

There are no index measures for adaptive optics retinal imaging in this disease; change from baseline will be the exploratory endpoint measured here.

Change from baseline in laser speckle flowgraphyBaseline through Month 6

There is one index measure of retinal blood flow response to light stimulation; change from baseline with a statistically significant difference from test-retest variability will be the exploratory endpoint measured here.

Change from baseline in OCT angiographyBaseline through Month 6

There are 3 index measures of retinal blood flow in OCT-A; change from baseline with a statistically significant difference from test-retest variability will be the exploratory endpoint measured here.

Trial Locations

Locations (1)

Byers Eye Institute

🇺🇸

Palo Alto, California, United States

© Copyright 2025. All Rights Reserved by MedPath