跳至主要内容
临床试验/NCT06659419
NCT06659419招募中不适用

Registry of PHAcoemulsification for Cataract Surgery

Assistance Publique - Hôpitaux de Paris1 个研究点 分布在 1 个国家目标入组 100,000 人开始时间: 2024年10月1日最近更新:
适应症

试验速览

阶段
不适用
状态
招募中
入组人数
100,000
试验地点
1
主要终点
Description of intraoperative parameters during cataract surgery when using Active Sentry

研究概览

简要总结

Cataracts cause vision loss due to opacities in the lens. Cataract surgery is performed by emulsifying the nucleus of the lens. A phacoemulsifier is the machine used to deliver ultrasonic energy in the eye to fragment the lens and aspirate the debris.

In contrast to the large number of cataract procedures performed worldwide, there is surprisingly scarce data regarding the intraoperative parameters used during phacoemulsification. As new technologies are made available to surgeons, this impedes a large-scale analysis of the benefits of the advances in phacoemulsifiers. The investigators aim to establish a nationwide registry with a database of intraoperative data recorded during the cataract procedures performed with the Centurion phacoemulsifier.

The data collected would encompass all parameters recorded in the phacoemusifiers' logs, such as the energy delivered in the eye (longitudinal, torsional and other), US time, BSS volume, duration of the procedure, surgeon settings and others. The objective will be to capture data from at least 100,000 procedures/year.

详细描述

A nationwide registry will be established with a database of intraoperative data recorded during the cataract procedures performed with the Centurion phacoemulsifiers. The following intraoperative parameters used during the cataract surgery will be recorded and analyzed:

Primary endpoint: Ultrasound time (US time)

Exploratory endpoints:

  • CDE : Cumulated dissipated Energy
  • Total surgery time
  • BBS volume
  • Torsional and longitudinal energy
  • IOP settings
  • Vacuum settings Procedures performed with the Active Sentry module - where a pressure sensor is built in the phacoemulsifier handpiece will be compared to other to procedures performed without this module.

Data will be collected and analyzed from Centurions cases log extracted from at least 200 Centurions installed in France. Parameter and settings will be retrospectively analyzed.

研究设计

研究类型
Observational
观察模型
Other
时间视角
Other

入排标准

性别
All
接受健康志愿者

入选标准

  • All procedures recorded in Centurions (200 machines).

排除标准

  • Opposition of the center to data collection.
  • Complicated surgery (e.g. anterior vitrectomy) identified as such in the event log

结局指标

主要结局

Description of intraoperative parameters during cataract surgery when using Active Sentry

时间窗: time of the surgery

To describe intraoperative parameters during cataract surgery when using Active Sentry compared with other handpieces in a large registry comprising at least 200 centurions (\>85 benefiting from the Active Sentry upgrade). Data will be collected and analyzed from event logs extracted from 200 Centurions installed in France. Parameters and settings will be analyzed retrospectively.

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验

Registry of PHAcoemulsification for Cataract Surgery | 临床试验