A Post Market Study to Confirm the Safety and Performance of the Signia™ Stapling System.

Completed
Conditions
Abdominal Injury
Thoracic Diseases
Interventions
Device: Signia™ Stapling System
Registration Number
NCT03515811
Lead Sponsor
Medtronic - MITG
Brief Summary

The objectives of this prospective, two-arm, multicenter post-market study is to confirm safety and performance through the incidence of subjects reporting serious adverse device effects (ADEs) up to and including 30 days following use of Signia™ Stapling System with Endo GIA™ with Tri-Staple™ Technology and Tri-Staple™ 2.0 Intelligent Reloads in subjects undergoing indicated abdominal or thoracic procedures for resection, transection and creation of anastomosis per the IFU.

Detailed Description

This study will evaluate the use of Signia™ Stapling System using Signia™ Intelligent Loading Units with Tri-Staple™ 2.0 Intelligent Reloads in indicated abdominal or thoracic procedures (e.g., resection, transection of tissue, and creation of anastomoses). Subjects who meet the eligibility criteria will be considered for study participation at a minimum of 10 sites and will be followed up to and including 30 days post-operative. Overall the study is estimated to progress for up to 24 months.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
136
Inclusion Criteria
  1. Adults (male or female) between 22 and 80 years of age inclusive at the time of the procedure.
  2. The subject must be willing and able to participate in the study procedures and to understand and sign the informed consent.
  3. The subject is scheduled to undergo an indicated primary abdominal or thoracic procedure for resection, transection and creation of anastomosis per the IFU where the Signia™ Stapling System with Endo GIA™ with Tri-Staple™ Technology and Tri-Staple™ 2.0 Intelligent Reloads will be used per its IFU.Additionally, if considered appropriate for the procedure only Medtronic buttresses can be used during the course of the study.

3a. Thoracic procedures may include, but are not limited to wedge resection and lobectomy, and may include video assisted thoracic surgery (VATS) or open procedures.

3b. Abdominal procedures may include, but are not limited to, laparoscopic sleeve gastrectomy (LSG), laparoscopic Roux-en-Y gastric bypass (LRYGB).

Exclusion Criteria
  1. Subjects undergoing cardiac and vascular procedures.
  2. The procedure is an emergency procedure.
  3. The procedure is a revision/reoperation of a primary operation..
  4. Any female subject who is pregnant. 4a. Females of child-bearing potential will be required to undergo either a urine pregnancy test or serum pregnancy test during Screening and confirmed on the day of operation (except for subjects who are surgically sterile or are post-menopausal for at least two years) (USA only) and per EU local requirements.
  5. Any subject who is considered to be part of a vulnerable population (e.g. prisoners or those without sufficient mental capacity).
  6. The subject is unable or unwilling to comply with the study requirements or follow-up schedule.
  7. The subject has comorbidities which, in the clinical judgment of the Investigator, will not be appropriate for the study or the subject has an estimated life expectancy of less than 6 months.
  8. The subject has been diagnosed with a bleeding disorder and/or is undergoing active and not reversed anticoagulant treatment.
  9. The subject is concurrently enrolled in another investigational drug or device research study or has been enrolled in another study within 30 days of enrollment.
  10. Pre-existing/chronic conditions specific to Tri-Staple™ 2.0 Reload contraindications as described in the IFU.

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Arm && Interventions
GroupInterventionDescription
AbdominalSignia™ Stapling SystemSignia™ Stapling System using Signia™ Intelligent Loading Units with Tri-Staple™ 2.0 Intelligent Reloads. Abdominal (approximately 53 subjects).
ThoracicSignia™ Stapling SystemSignia™ Stapling System using Signia™ Intelligent Loading Units with Tri-Staple™ 2.0 Intelligent Reloads. Thoracic (approximately 74 subjects).
Primary Outcome Measures
NameTimeMethod
The Primary Endpoint is the Number of Subjects Reporting Serious Adverse Device Effects (SADEs), Including Intra- and Post-operative Leaks.Up to and including 30 (+14) days post-procedure.

The primary endpoint is the number of subjects reporting serious adverse device effects (SADEs), including intra- and post-operative leaks up to and including 30 (+14) days post-procedure. A Serious Adverse Device Effect (SADE) is an adverse event related to the use of an investigational medical device, that is deemed serious in nature. To be deemed serious, and adverse event must meet one or more of the following criteria:

Led to a death, b. Led to a serious deterioration in the health of the subject, that either resulted in:

1. Resulted in a life-threatening illness or injury, or

2. Resulted in a permanent impairment of a body structure or a body function, or

3. In-patient or prolonged hospitalization, or

4. Medical or surgical intervention to prevent life threatening illness or injury or permanent impairment to a body structure or a body function, or c. Led to fetal distress, fetal death or a congenital abnormality or birth defect.

Secondary Outcome Measures
NameTimeMethod
The Secondary Endpoint is the Intra-operative Staple Line Assessment Assessing: Number of Staple-line Bleeding (Measured as > 50 cc) Occurrences.Up to and including 30 (+14) days post-operative.

The secondary endpoint is device deficiency/malfunctions affecting the intended performance of the device including: intra- and post-operative staple line assessments. Number of staple-line bleeding (measured as \> 50 cc) refers to occurrences of bleeding at the staple-line only, and not in the study procedure as a whole.

The Secondary Endpoint is the Intra-operative Staple Line Assessment Assessing: Additional Interventions to Treat Staple-line Failure.Up to and including 30 (+14) days post-operative.

The secondary endpoint is device deficiency/malfunctions affecting the intended performance of the device including: intra- and post-operative staple line assessments. Examples of additional interventions to treat staple-line failure include: glue, manual over sew, Medtronic buttress as additional reinforcement, or intraoperative revision/recreation of the anastomosis.

The Secondary Endpoint is the Post-operative Surgical Site Assessment Assessing: Number of Post-operative Leakage.Up to and including 30 (+14) days post-operative.

The secondary endpoint is device deficiency/malfunctions affecting the intended performance of the device including: intra- and post-operative staple line assessments. Number of post-operative leakage as evidenced confirmed by imaging, subject presentation or decline in status, or need for re-operation/re-intervention.

The Secondary Endpoint is the Intra-operative Staple Line Assessment Assessing: Number of Intra-operative Leakage.Up to and including 30 (+14) days post-operative.

The secondary endpoint is device deficiency/malfunctions affecting the intended performance of the device including: intra- and post-operative staple line assessments. Number of intra-operative leakage as measured by air leak test performed by the surgeon, or standard of care, as applicable.

The Secondary Endpoint is the Post-operative Surgical Site Assessment Assessing: Number of Repeat Hospital Admissions for Primary Procedure-related Complications.Up to and including 30 (+14) days post-operative.

The secondary endpoint is device deficiency/malfunctions affecting the intended performance of the device including: intra- and post-operative staple line assessments. The number of repeat hospital admissions for primary procedure-related complications was assessed.

The Secondary Endpoint is the Intra-operative Staple Line Assessment Assessing: Staple Line Integrity (B Formation).Up to and including 30 (+14) days post-operative.

The secondary endpoint is device deficiency/malfunctions affecting the intended performance of the device including: intra- and post-operative staple line assessments. B formation is defined as consistent formation of the staple-line fired by the Signia Stapling System handle.

The Secondary Endpoint is the Post-operative Surgical Site Assessment Assessing: Duration of Air Leakage >7 Days.Up to and including 30 (+14) days post-operative.

The secondary endpoint is device deficiency/malfunctions affecting the intended performance of the device including: intra- and post-operative staple line assessments. Prolonged air leaks are considered \>7 days in duration.

The Secondary Endpoint is the Post-operative Surgical Site Assessment Assessing: Number of Post-operative Infection.Up to and including 30 (+14) days post-operative.

The secondary endpoint is device deficiency/malfunctions affecting the intended performance of the device including: intra- and post-operative staple line assessments. Number of post-operative infection was assessed by the Investigator according to the standard of care and site policy, ex. Positive wound culture.

The Secondary Endpoint is Device Deficiencies/Malfunctions Affecting the Intended Performance of the Device.Up to and including 30 (+14) days post-operative.

The secondary endpoint is device deficiencies/malfunctions affecting the intended performance of the device. All recorded device deficiencies/malfunctions were captured and assessed by the Investigator. A Device Deficiency is defined as inadequacy of a medical device with respect to its identity, quality, durability, reliability, safety or performance.

Note: Device deficiencies include malfunctions, use errors, and inadequate labeling.

The Secondary Endpoint is the Post-operative Surgical Site Assessment Assessing: Additional Interventions to Treat Staple-line Failure.Up to and including 30 (+14) days post-operative.

The secondary endpoint is device deficiency/malfunctions affecting the intended performance of the device including: intra- and post-operative staple line assessments. Examples of additional interventions to treat staple-line failure include: glue, manual over sew, Medtronic buttress as additional reinforcement, or intraoperative revision/recreation of the anastomosis.

Trial Locations

Locations (11)

Cedars Sinai Medical Center

🇺🇸

Los Angeles, California, United States

Albany Medical College

🇺🇸

Albany, New York, United States

WakeMed Bariatric Specialists of North Carolina

🇺🇸

Cary, North Carolina, United States

Inova Fairfax Hospital

🇺🇸

Falls Church, Virginia, United States

Azienda Ospedaleria San Gerardo

🇮🇹

Monza, Italy

Institut Universitaire de Cardiologie et de Pneumologie de Quebec

🇨🇦

Québec, Quebec, Canada

Hospital Universitario del Rocio

🇪🇸

Sevilla, Spain

Hospital Universitario Virgen Macarena

🇪🇸

Sevilla, Spain

Blackpool Victoria Hospital

🇬🇧

Blackpool, United Kingdom

UNC Chapel Hill

🇺🇸

Chapel Hill, North Carolina, United States

Duke Regional Hospital

🇺🇸

Durham, North Carolina, United States

© Copyright 2025. All Rights Reserved by MedPath