临床试验/NCT00140530
NCT00140530已完成4 期

A Randomized Trial of a Nonpolymer-Based Rapamycin-Eluting Stent Versus a Polymer-Based Paclitaxel-Eluting Stent for the Prevention of Restenosis (ISAR-TEST-1)

Deutsches Herzzentrum Muenchen4 个研究点 分布在 1 个国家目标入组 450 人开始时间: 2004年3月1日最近更新:
适应症

试验速览

阶段
4 期
状态
已完成
发起方
入组人数
450
试验地点
4
主要终点
In-stent late luminal loss

研究概览

简要总结

The purpose of this study is to assess the efficacy of nonpolymer-based rapamycin-eluting stent compared to standard polymer-based paclitaxel-eluting stent to reduce reblockage of coronary arteries.

详细描述

Drug-eluting stents represent a major advance in the treatment of restenosis. They have dramatically reduced the need of repeat revascularization procedures, and, thanks to the excellent results obtained in various patient subsets, these devices are now used in almost 90% of the stent implantation procedures performed in US hospitals. Along with the increasing number of patients receiving drug-eluting stents and availability of long-term follow-up data, concern has arisen regarding the safety of these devices. At the core of this concern is the potential for increased inflammatory and thrombogenic responses and their life-threatening consequences associated with the polymers employed for the delivery of antirestenotic agents. A growing interest has been shown on polymer-free stents with a microporous surface as an alternative to stents employing polymeric coating for local drug delivery. Recently, we developed a mobile system which enables coating in the catheterization laboratory of polymeric free stents with different drug doses or combinations. Using a porcine coronary model of restenosis, we found that coating with rapamycin of a polymer-free microporous stent is feasible and effectively reduces neointimal proliferation. More recently, in a clinical study in which the efficacy of several doses of rapamycin was assessed, we showed that non-polymer coating with rapamycin is safe and leads to a dose-dependent reduction in restenosis. While the advantage deriving from the lack of polymeric cover in on-site coated rapamycin-eluting stents is readily understandable, their relative efficacy as compared with commercially available polymer-based drug-eluting stents has yet to be evaluated.

Comparison:

Polymer-free microporous stents coated with rapamycin versus standard polymer-based, paclitaxel-eluting stents

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients at least 18 years old
  • Stable or unstable angina or a positive stress test
  • "de novo" coronary artery lesions
  • Written informed consent

排除标准

  • Myocardial infarction within 48 h. before enrollment
  • Target lesion located in left main trunk
  • Contraindication or known allergy to aspirin, heparin, thienopyridines, rapamycin, paclitaxel or stainless steel

结局指标

主要结局

In-stent late luminal loss

时间窗: 6 months

次要结局

  • Angiographic restenosis at follow-up angiography(6 months)
  • Need for target lesion revascularization due restenosis at 9 months(9 months)