Single-center, Double-arm, Prospective Clinical Trial to Compare Visual Performance of Non-diffractive Extended Vision and Neutral Aspheric Monofocal Intraocular Lenses
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 56
- 试验地点
- 2
- 主要终点
- Binocular Intermediate Vision
研究概览
简要总结
The purpose of this study is to compare the binocular distance, intermediate, and near visual acuity of the Alcon Vivity and Bausch & Lomb enVista IOLs.
We hypothesize that the Alcon Vivity and Bausch & Lomb enVista IOLs will have similar distance, intermediate, and near visual acuity. If the null hypothesis is rejected, then the visual performance of the IOLs may be different.
详细描述
Presbyopia correcting intraocular lens (PC-IOL) technology has been available for decades. Lens designs have included refractive (e.g. AMO ReZoom), apodized diffractive (e.g. Alcon Acrysof ReSTOR/PanOptix), accommodating (B&L Crystalens), and extended depth-of-focus (e.g. J&J Symfony) technology. Spectacle independence is significantly higher with PC-IOLs when compared with that of monofocal IOLs.1,2 Despite their clear benefits, PC-IOLs are not without drawbacks. Any IOL that splits light to deliver distinct distance and near foci creates the potential for photic phenomenon, which patients may perceive as glare, haloes, and starbursts.3,4
Pseudoaccommodation is defined as an increased depth-of-focus in an emmetropic eye that does not have the ability to change its refractive power. Spherical aberration, which may come from the cornea or IOL, plays an important role in pseudoaccommodation.5,6 There is a small body of literature that IOLs (e.g. Mini WELL, SIFI, Catalina, Italy) with highly-positive spherical aberration can result in significant pseudoaccommodation and lower unwanted optical phenomena than current multifocal IOLs.7
The Alcon Vivity PC-IOL is a hydrophobic acrylic, non-diffractive, extended depth of focus IOL designed for implantation in the capsular bag following cataract extraction. The single-piece IOL has a 6.0 mm diameter and has a hyper-prolate profile that extends the depth of focus to deliver a broader range of sharp vision, with the glare and halo profile approaching that of a monofocal IOL.8
The Bausch & Lomb enVista MX60E is a posterior chamber hydrophobic acrylic IOL. The single-piece IOL has a 6.0 mm diameter and has a neural aspheric optical profile. This neutral aspheric profile, combined with the cornea's natural positive spherical aberration, may extend the depth of focus relative to other negative aspheric hydrophobic acrylic monofocal IOLs on the market.
To date, there is no existing literature comparing the visual performance and patient reported outcomes of the two above mentioned lens technologies; namely, one that relies on a non-diffractive, hyper-prolate profile and another that relies on the cornea's natural positive spherical aberration to provide pseudoaccommodation.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Treatment
- 盲法
- Double (Participant, Outcomes Assessor)
入排标准
- 年龄范围
- 18 Years 至 95 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Male or female, age 18 or older at the time of study enrollment.
- •Visually significant cataract in the study eyes for which phacoemulsification cataract extraction and posterior chamber IOL implantation is indicated.
- •Anticipated to undergo bilateral sequential cataract surgery
- •Projected postoperative CDVA 0.20 logMAR (Snellen 20/32) or better in the study eyes, as determined by an Investigator's medical judgement.
- •Calculated spherical power targeted at emmetropia at distance in the study eyes.
- •Calculated IOL power between +15.0 - +25.0 D, inclusive, in both eyes.
- •Measured against-the-rule astigmatism less than 0.6 D or with-the-rule/oblique astigmatism less than 1.25 D.
- •If wearing rigid gas permeable (RGP) contact lens in the study eye, willingness to discontinue lens wear for ≥ 21 days prior to preoperative biometry.
- •Availability, willingness, and sufficient cognitive awareness to return for study-required visits and comply with examination procedures.
- •Willingness to sign the IRB-approved informed consent form (ICF) for study participation.
排除标准
- •Mature cataract in the study eye that is likely to prolong surgical procedure and/or lead to intraoperative complications prior to attempted IOL implantation.
- •Any visually significant intraocular media opacity other than cataract in the study eye (as determined by the investigator). Such opacities might include corneal scar or vitreous hemorrhage.
- •Abnormal corneal findings in the study eye (e.g. keratoconus, pellucid marginal degeneration, irregular astigmatism).
- •Any anterior segment pathology in the study eye that could significantly affect outcomes (e.g. chronic uveitis, iritis, aniridia, clinically significant corneal dystrophies, poor pupil dilation, etc.)
- •Any condition in the study eye that could affect IOL stability (e.g. pseudoexfoliation, zonular dialysis, evident zonular weakness or dehiscence, etc.).
- •History of severe dry eye in the study eye that, in the judgement of the investigator, would impair the ability to obtain reliable study measurements.
- •History of serious corneal disease (e.g. herpes simplex, herpes zoster keratitis, etc.) in the study eye.
- •History of any clinically significant retinal pathology or ocular diagnosis in the study eye that could, in the investigator's best judgement, alter or limit final post-operative visual prognosis (e.g. diabetic retinopathy, ischemic disease, macular degeneration, retinal detachment, optic neuropathy, amblyopia, strabismus, aniridia, epiretinal membrane, etc.).
- •History of cystoid macular edema in either eye.
- •History of uveitis in either eye.
- •History of intraocular or corneal surgery in the study eye besides laser peripheral iridotomy (LPI), selective laser trabeculoplasty (SLT), or argon laser trabeculoplasty (ALT).
- •Uncontrolled glaucoma in the study eye (per Investigator judgement).
- •Current ocular infection in the study eye.
- •Presence of uncontrolled systemic disease that could increase operative risk (e.g. diabetes mellitus, mental illness, dementia, clinically significant atopic disease, etc.).
- •Planned concomitant ocular procedure during cataract surgery inclusive of glaucoma surgery e.g. MIGS or limbal relaxing incisions.
- •Symptoms that might be consistent with active COVID-19 including fever, chills, cough, shortness of breath or difficulty breathing, fatigue, muscle or body aches.
- •If COVID-19 positive, at least two weeks since last symptoms.
- •Unsuitable for study participation for any other reason, as determined by the Investigator's clinical judgement.
结局指标
主要结局
Binocular Intermediate Vision
时间窗: 3 months
Mean logMAR best-distance corrected visual acuity at intermediate (66 cm) tested in binocular photopic conditions at 3 months.
次要结局
未报告次要终点
研究者
Seth M Pantanelli
Associate Professor of Ophthalmology
Milton S. Hershey Medical Center
