Respiratory Variations For Predicting Fluid Responsiveness 2

Not Applicable
Completed
Conditions
Respiratory Physiological Phenomena
Sepsis
Circulatory Failure
Interventions
Device: Echocardiography-Doppler
Registration Number
NCT03066375
Lead Sponsor
University Hospital, Lille
Brief Summary

Objectives: To investigate whether respiratory variations of inferior vena cava diameters (cIVC) predict fluid responsiveness in spontaneously breathing patients with septic acute circulatory failure and irregular heartbeats.

Design: Prospective, bicentric study, intensive care units.

Patients and measures: Spontaneously breathing patients with sepsis and clinical signs of acute circulatory failure are included. A positive response to fluid loading (FL) is defined as an increase of the stroke volume (SV) \>10%. The investigators measured the minimum inspiratory and maximum expiratory diameters of the IVC (idIVC and edIVC) during standardized (st) and unstandardized (ns) breathing. The investigators calculated cIVCst and cIVCns before a 500ml-colloid FL.

Detailed Description

Not available

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
55
Inclusion Criteria
  • Adult patients of the intensive care units of the Lille university-hospital and of the Valencienne general hospital.

  • Age greater than or equal to 18.

  • Patient insured

  • Spontaneous breathing without ventilatory support or intubation or tracheotomy.

  • Irregular cardiac rhythm

  • Prescription by the physician in charge of the patients of a 500 mL volume expansion in less than 30 minutes.

  • Patients with sepsis with at least one sign of acute circulatory failure:

    • Tachycardia with heart rate> 100/min
    • systolic blood pressure <90mmHg or a decrease >40mmHg in previously hypertense patient
    • Oliguria <0.5ml/kg/hour for at least one hour
    • skin mottling
Exclusion Criteria
  • high-grade aortic insufficiency
  • transthoracic echogenicity unsuitable for measuring the stroke volume or inferior vena cava diameters
  • clinical signs of active exhalation
  • clinical or ultrasonographic evidence of pulmonary edema due to heart failure
  • pregnancy
  • abdominal compartment syndrome
  • regular cardiac rhythm

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
Echocardiography-DopplerEchocardiography-DopplerUltrasonographic recordings, systemic arterial pressure, heart rate, and respiratory rate are recorded immediately before and after volume expansion (VE), performed as a 30-minute infusion of 500 mL of 4% gelatin. Inferior Vena Cava diameters are measured during spontaneous and standardized respiratory cycles. Stroke volume is measured during spontaneous respiratory cycles.
Primary Outcome Measures
NameTimeMethod
respiratory variations in inferior vena cava diameters with respect to the response to fluid resuscitation, assessed by the area under the ROC curveduring 30 minutes of the volume expansion
Secondary Outcome Measures
NameTimeMethod

Trial Locations

Locations (1)

Intensive Care Department, Salengro Hospital,CHRU

🇫🇷

Lille, France