跳至主要内容
临床试验/NCT04608916
NCT04608916已完成不适用

Efficacy of Surgical Diathermy in Eradicating Cutibacterium Acnes From Surgical Skin Incision During Shoulder Arthroplasty

University of Missouri-Columbia2 个研究点 分布在 1 个国家目标入组 64 人开始时间: 2021年6月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
64
试验地点
2
主要终点
Proportions of positive C acnes cultures

研究概览

简要总结

Periprosthetic infection following shoulder arthroplasty is a devastating complication. Diagnosing and treating periprosthetic shoulder infection poses a significant challenge. At the forefront of this issue is Cutibacterium acnes because the current prophylactic regimens are insufficient to eradicate C acnes from the surgical field. It is believed that C acnes infections occur during surgery when the sebaceous glands in the skin are cut and exposed, leading to C acnes contaminating the surgeon's instruments and gloves and, thus, the surgical wound. The purpose of this study is to examine if making skin incisions using electrocautery will result in decreased C acnes contamination during shoulder arthroplasty. To this end, we propose a randomized clinical trial where patients undergoing shoulder arthroplasty are randomized into two groups - Electrocautery incision group (Electro) vs. Scalpel incision group (Scalpel) - and swab cultures are obtained from the skin incision and operating surgeon's gloves and forceps

详细描述

Periprosthetic infection following shoulder arthroplasty is a devastating complication. Infected shoulder arthroplasty not only causes an unexpected health hazard to patients but also imposes a heavy financial burden at both individual and societal levels. The rates of periprosthetic shoulder infection (PSI) have been reported to be 0.80% to 1.46%, but the number of infections is likely to increase as shoulder arthroplasty becomes more commonplace in an aging active population. Diagnosing and treating PSI poses a significant challenge. Unlike periprosthetic infection in other joints, PSI lacks the typical clinical signs and laboratory findings of infection due to the indolent nature of the offending pathogens. At the forefront of this issue is Cutibacterium acnes. Although the typical Staphylococcus, Streptococcus, and Corynebacterium species that reside on the skin surface are the primary targets of most surgical infection prophylaxis regimens, C acnes has emerged as a problematic bacterium because the current prophylactic regimens are insufficient to eradicate C acnes from the surgical field.

C acnes is one of the most common pathogens of infections after shoulder surgery. It is a commensal, gram-positive anaerobic bacillus that resides in the sebaceous glands associated with hair follicles. The colonization with C acnes of the front and back side of the shoulder epidermis is greater than that of other regions of the body because of the high density of the sebaceous glands in that area. C acnes can cause low-grade infections after shoulder surgery, and it has been shown that it is the most commonly detected bacterium after revision shoulder arthroplasty surgery. During revision shoulder arthroscopy cases performed for pain, stiffness, or weakness, 30% of patients had positive culture findings, and 80% of those findings were positive for C acnes. It is believed that C acnes infections occur during surgery when the sebaceous glands in the skin are cut and exposed, leading to C acnes contaminating the surgeon's instruments and gloves and, thus, the surgical wound. Recent studies showed that hydrogen peroxide and benzoyl peroxide were more effective than the conventional skin preparation methods in decreasing the C acnes load in the skin, but as high as 17% of the cultures were still positive for C acnes even with these new measures. Thus, despite all the efforts to eradicate C acnes from the shoulder, C acnes remain an elusive pathogen that is potentially contaminating tens of thousands of shoulder arthroplasties each year.

Surgical diathermy (or electrocautery) has been used routinely for tissue dissection and hemostasis during surgical procedures. In the cutting mode, the use of an electrode delivering a pure continuous sinusoidal wave of low voltage produces as high temperatures as 1000℃, which heats cells within the tissue so rapidly that they vaporize, leaving a cavity within the cell matrix. The heat created dissipates as a stream rather than being transmitted into adjacent tissues. This allows tissue cleavage without damage to surrounding areas. The electrode does not need to be in contact with tissue as an arc is formed producing a clean cut. With the coagulation mode on high power, cutting also occurs, but this produces a larger zone of greater thermal damage. Electrocautery can be used for dissecting fascia and muscle layers, as well as achieving hemostasis, and it has become an integral part of modern surgical practice. A number of clinical studies evaluated the safety and efficacy of cutting electrocautery for surgical incisions in general, plastic, otorhinolaryngological, orthopedic, neurosurgical, and gynecologic procedures. Additionally, systematic reviews and meta-analyses were conducted for the same purposes. The majority of these studies showed that using electrocautery to cut the skin provided the benefits of reduced bleeding, a quicker incision, and decreased postoperative pain with no increase of wound complications when compared to scalpel incisions. Given the high temperatures generated at the tip of an electrode of electrocautery, it is reasonable to assume that making a skin incision with electrocautery could potentially destroy exposed colonies of C acnes in hair follicles and sebaceous glands open on the incisional surface of the skin. The purpose of this study is to examine if making skin incisions using electrocautery will result in decreased C acnes contamination during shoulder arthroplasty. To this end, we propose a randomized clinical trial where patients undergoing shoulder arthroplasty are randomized into two groups - Electrocautery incision group (Electro) vs. Scalpel incision group (Scalpel) - and swab cultures are obtained from the skin incision and operating surgeon's gloves and forceps.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Prevention
盲法
Single (Outcomes Assessor)

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
Male
接受健康志愿者

入选标准

  • Adult male patients (>18 years old) who undergo primary shoulder arthroplasty (either anatomic or reverse shoulder arthroplasty)

排除标准

  • History of ipsilateral shoulder postoperative infection
  • Administration of any antibiotics within a month prior to the index procedure
  • Active acne at the surgical site
  • History of psoriatic or eczematous lesions about the shoulder area
  • Revision arthroplasty cases
  • Minors (< 18 years old)
  • Female patients
  • Prisoners
  • Patients who cannot understand English enough to give an informed consent

结局指标

主要结局

Proportions of positive C acnes cultures

时间窗: 2 weeks following surgery

Proportions of positive C acnes cultures

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

H. Mike Kim

Associate Professor

University of Missouri-Columbia

研究点 (2)

Loading locations...

相似试验