MedPath

Individualized Transcranial Direct Current Stimulation for Gait Function in Healthy Subjects

Not Applicable
Terminated
Conditions
Healthy Aging
Healthy Adults
Interventions
Device: Conventional transcranial direct current stimulation
Device: Individualized transcranial direct current stimulation
Registration Number
NCT04030793
Lead Sponsor
Samsung Medical Center
Brief Summary

The purpose of this study is to compare the effects of individualized brain stimulation based on simulation and conventional brain stimulation in healthy adults.

Detailed Description

Not available

Recruitment & Eligibility

Status
TERMINATED
Sex
All
Target Recruitment
19
Inclusion Criteria

• Healthy adult men and women without history of central nervous system disease and abnormalities

Exclusion Criteria
  • Under 18 years old, 75 years old or older
  • A person who has inserted a metal object in a skull
  • A person with complete occlusion of the carotid artery
  • A person with epilepsy
  • Pregnant and lactating women
  • Who is not eligible for the test

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
Conventional stimulation groupConventional transcranial direct current stimulationConventional stimulation on leg motor areas during 30 minutes.
Individualized stimulation groupIndividualized transcranial direct current stimulationBased on transcranial direct current stimulation (tDCS) simulation, individualized stimulation on leg motor areas during 30 minutes.
Primary Outcome Measures
NameTimeMethod
Changes in cortical activationChange from baseline (before stimulation) after stimulation during 30 min

changes in cortical activation is measured by functional Near-Infrared-Spectroscopy (fNIRS) (NIRScout, NIRx, Germany) during treadmill gait.

Secondary Outcome Measures
NameTimeMethod
Gait analysis using motion analysis systemBefore stimulation (baseline); After strimulation during 30 min

Gait analysis is a process of measuring and evaluating the walking patterns of patients by using motion analysis system.

10 meter walk test (10MWT)Before stimulation (baseline); After strimulation during 30 min

Measure of self selected speeds by measuring the time it takes an individual to walk 10 meters. To perform the test, patient walks 10 meters (33 ft) and the time is measured when the leading foot crosses the start line and the finish line. The instructions are: "Please walk this distance at your normal pace when I say go."

Timed Up and Go test (TUG)Before stimulation (baseline); After strimulation during 30 min

The Timed Up and Go test (TUG) is a simple test used to assess a person's mobility and requires both static and dynamic balance. It uses the time that a person takes to rise from a chair, walk three meters, turn around, walk back to the chair, and sit down.

Gait analysis using surface electromyographBefore stimulation (baseline); After strimulation during 30 min

Gait analysis is a process of measuring and evaluating the walking patterns of patients by using surface electromyograph.

Trial Locations

Locations (1)

Samsung Medical Center

🇰🇷

Seoul, Korea, Republic of