跳至主要内容
临床试验/NCT00292474
NCT00292474已完成2 期

TAXUS IV-SR: Treatment of De Novo Coronary Disease Using a Single Paclitaxel-Eluting Stent

Boston Scientific Corporation2 个研究点 分布在 1 个国家目标入组 1,326 人开始时间: 2002年3月最近更新:
适应症

试验速览

阶段
2 期
状态
已完成
入组人数
1,326
试验地点
2
主要终点
The primary objective of this study is to evaluate the safety and effectiveness of the TAXUS Stent System with 1 ug/mm2 (loaded drug/stent surface area) of paclitaxel incorporated into a slow rate-release formulation of a triblock copolymer carrier syst

研究概览

简要总结

The ultimate goal of a paclitaxel eluting stent system (TAXUS stent) is to prevent restenosis by blunting the initial response to stent implant injury and sustaining the arrested response until vascular healing has taken place.

The purpose of the TAXUS IV-SR trial is to study the safety and efficacy of the TAXUS Stent under controlled trial circumstances used in the treatment of new coronary artery lesions (heart blockages) This clinical investigation will evaluate the safety and effectiveness of the TAXUS Stent with 1 ug/mm2 (loaded drug/stent surface area) of paclitaxel incorporated into a slow rate-release formulation of a triblock copolymer carrier system for treatment of new coronary artery lesions.

详细描述

This was a prospective randomized, double-blind, multicenter safety and efficacy trial. Patients were stratified by presence or absence of medically treated diabetes mellitus and vessel diameter (<3.0 mm or >/=3.0 mm), then randomized 1:1 to receive either the TAXUS Stent or a Control stent. Additional study stents were permitted to optimize outcomes. The study was considered complete (with regard to the primary endpoint) after all patients enrolled had completed the 9 month follow-up.

Enrollment of 1172 patients was planned; 1326 were treated and randomized at 73 centers involving 76 sites by 8 July 2002 with 667 in the TAXUS group and 659 in the Control group.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Double (Participant, Investigator)

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patient is > or = 18 years old
  • Eligible for percutaneous coronary intervention (PCI)
  • Documented stable angina pectoris (Canadian Cardiovascular Society Classification [CCS] 1, 2, 3, or 4) or unstable angina pectoris with documented ischemia (Braunwald Class IB-C, IIB-C, or IIIB-C), or documented silent ischemia
  • Left ventricular ejection fraction (LVEF) of > or = 25%
  • Acceptable candidate for CABG
  • Patient (or legal guardian) understands the study requirements and the treatment procedures and provides written Informed Consent before any study-specific tests or procedures are performed
  • Willing to comply with all specified follow-up evaluations
  • Target lesion located within a single native coronary vessel
  • Target lesion randomized to treatment with the study device may be composed of multiple lesions but must be completely coverable by one (1) study stent
  • Cumulative target lesion length is > or = 10 mm and < or = 28 mm (visual estimate)
  • RVD of > or = 2.5mm to < or = 3.75 mm (visual estimate)
  • Target lesion diameter stenosis > or = 50% (visual estimate)
  • Target lesion is de novo (i.e., a coronary lesion not previously treated)
  • Target lesion located within a single native coronary vessel
  • Target lesion randomized to treatment with the study device may be composed of multiple lesions but must be completely coverable by one (1) study stent
  • Cumulative target lesion length is > or = 10 mm and < or = 28 mm (visual estimate)
  • RVD of > or = 2.5mm to < or = 3.75 mm (visual estimate)
  • Target lesion diameter stenosis > or = 50% (visual estimate)
  • Target lesion is de novo (i.e., a coronary lesion not previously treated)

排除标准

  • Known sensitivity to paclitaxel
  • Any previous or planned treatment with a non-study anti-restenotic drug-coated or drug-eluting coronary stent. (Note: previous or planned treatment with heparin or phosphorylcholine coated stents is acceptable, as long as the procedure with the non-study stent meets the protocol defined criteria for staged procedures)
  • Previous or planned treatment with intravascular brachytherapy in the target vessel
  • MI within 72 hours prior to the index procedure and/or CK-MB >2x the local laboratory's upper limits of normal (refers to a measured value on the day of the index procedure)
  • Cerebrovascular Accident (CVA) within the past 6 months
  • Acute or chronic renal dysfunction (creatinine >2.0 mg/dl or >150 µmol/L)
  • Contraindication to ASA, or to both clopidogrel and ticlopidine
  • Leukopenia (leukocyte count <3.5 x 109/liter)
  • Thrombocytopenia (platelet count <100,000/mm3)
  • Active peptic ulcer or active gastrointestinal (GI) bleeding
  • Known allergy to stainless steel
  • Any prior true anaphylactic reaction to contrast agents
  • Known anaphylactoid or other non-anaphylactic allergic reactions to contrast agents that cannot be adequately pre-medicated prior to the index procedure
  • Patient is currently taking colchicine
  • Patient is currently, or has been treated with paclitaxel within 12 months of the index procedure
  • Female of childbearing potential with a positive pregnancy test within 7 days before the index procedure, or lactating, or intends to become pregnant during the study
  • Life expectancy of less than 24 months due to other medical conditions
  • Co-morbid condition(s) that could limit the patient's ability to participate in the study, compliance with follow-up requirements or impact the scientific integrity of the study
  • Currently participating in another investigational drug or device study that has not completed the primary endpoint or that clinically interferes with the endpoints of this study

结局指标

主要结局

The primary objective of this study is to evaluate the safety and effectiveness of the TAXUS Stent System with 1 ug/mm2 (loaded drug/stent surface area) of paclitaxel incorporated into a slow rate-release formulation of a triblock copolymer carrier syst

次要结局

  • Secondary endpoints include the following:
  • • Rates of composite MACE and the individual components of MACE (MI, TVR, Cardiac Death), assessed at 1, 4 and 9 months after the index procedure and annually for 5 more years (i.e., 1, 2, 3, 4, and 5 years after the index procedure).
  • • Stent thrombosis rate
  • • Target Vessel Failure
  • • Clinical procedural success
  • • Binary restenosis rate

研究者

申办方类型
Industry

研究点 (2)

Loading locations...

相似试验