The Influences Of Anterior Capsule Polishing On Anterior Capsular Changes and Intraocular Lenses Stability of Super High Myopic Eyes
- Conditions
- Myopia, High, With Cataract and Anterior Capsule Polished
- Interventions
- Procedure: 360°anterior capsule polishing
- Registration Number
- NCT03142269
- Lead Sponsor
- yin ying zhao
- Brief Summary
A prospective study included 20 patients with super high myopia who underwent bilateral uneventful cataract. 360°anterior capsule polishing was performed with double-ended capsule polisher randomly in one eye, and the opposite unpolished was used as the control. The refractive state and size of anterior opening were measured at postoperative 1 day as the baseline. Then they followed up at 1 month, 3 months and 6 months after surgery to record refractive state, higher-order aberrations, size of anterior opening, tilt and decentration of IOL (intraocular lenses)and PAD(postoperative aqueous depth). The paired t test was used to compare the differences between the two groups, and the same test the postoperative follow-up comparing with the baseline.
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 20
cataract patients with super high myopia (axial length >27mm) and difference of binocular was less than 1mm
larger corneal astigmatism need toric intraocular lens; patients with any systemic or ocular diseases that may influence the anterior capsule opening morphologic, such as keratonosus, glaucoma, uveitis, Pseudoexfoliation syndrome, retinitis pigmentosa and diabetes and Myotonic Dystrophy, etc.; patients with ophthalmic surgery and trauma history.
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- PARALLEL
- Arm && Interventions
Group Intervention Description unpolished group 360°anterior capsule polishing the opposite unpolished was used as the control polished group 360°anterior capsule polishing 360°anterior capsule polishing was performed with double-ended capsule polisher randomly in one eye
- Primary Outcome Measures
Name Time Method refraction Change from postoperative 1 day to 1 months refractive state
Stability of IOL Change from postoperative 1 months to 3 months Tilt and Decentration
anterior opening size Change from postoperative 1 day to 1 months area,diameter
- Secondary Outcome Measures
Name Time Method anterior opening size Change from postoperative 3 month to 6 months area,diameter
refraction Change from postoperative 3 month to 6 months refractive state
Stability of IOL Change from postoperative 3 month to 6 months Tilt and Decentration