Smart-glasses During the Ultrasound-guided Radial Arterial Catheterization in Pediatric Patients by Trainees
- Conditions
- Arterial Line
- Interventions
- Device: Smart glassesDevice: Control
- Registration Number
- NCT05030649
- Lead Sponsor
- Seoul National University Hospital
- Brief Summary
The primary objective of the study is to evaluate the effect of smart glasses (Head-mounted display Moverio BT-300 (Epson Inc., USA)) on the first-attempt success rate of radial artery cannulation in pediatric patients by less experienced trainees. This study hypothesizes that the use of smart glasses improves the hand-eye coordination and the first-attempt success rate of radial artery cannulation. This is a single-center, randomized, placebo-controlled study comparing the real-time ultrasound image through smart glasses (intervention group) or the ultrasound machine's monitor (control group) during the radial arterial cannulation in pediatric patients undergoing general anesthesia by less experienced trainees.
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 122
- General anesthesia
- Arterial cannulation for hemodynamic monitoring, multiple blood sample
- Unstable vital signs, significant arrhythmia or hypotension, Shock
- High risk of peripheral ischemia
- Skin disease, infection, hematoma, recent cannulation at theradial artery
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- PARALLEL
- Arm && Interventions
Group Intervention Description Smart Glasses Smart glasses The real-time ultrasound image is displayed through head-mounted display Moverio BT-300 (Epson Inc., USA) during the radial arterial cannulation. Control Control The real-time ultrasound image is displayed by the ultrasound machine's monitor during the radial arterial cannulation.
- Primary Outcome Measures
Name Time Method First attempt success rate During radial artery cannulation (up to 1 hour) Success at the first skin puncture
- Secondary Outcome Measures
Name Time Method Size of radial artery During radial artery cannulation (up to 1 hour) Internal diameter of radial artery
depth of radial artery During radial artery cannulation (up to 1 hour) depth of radial artery from the skin
Overall attempt During radial artery cannulation (up to 1 hour) Number of attempt of radial artery cannulation
Ultrasound image time During radial artery cannulation (up to 1 hour) From ultrasound probe application, to get radial artery image on the ultrasound screen
Arterial cannulation time During radial artery cannulation (up to 1 hour) From needle puncture, to Arterial waveform
Overall Procedure time During radial artery cannulation (up to 1 hour) From ultrasound probe application, to Arterial waveform
Overall success rate During radial artery cannulation (up to 1 hour) Success within 2 skin puncture and within 10 minutes at the chosen radial artery
Malfunction of radial artery catheter After radial artery cannulation assessed during anesthesia (up to 24 hour) Malfunction of Invasive blood pressure monitoring, Sampling
Complication rate After radial artery cannulation assessed up to PACU, PICU stay (up to 24 hour) Hematoma, Distal ischemia, Spasm accessed by ultrasound
Operator's experience During radial artery cannulation (up to 1 hour) The prior experience of the operator's in ultrasound-guided vascular cannulation (5-10 cannulations, 10-30 cannulations, 30-50 cannulations, 50-100 cannulations)
Operator's satisfaction During radial artery cannulation (up to 1 hour) Operator's satisfaction, 5 scale (Worst, Poor, Acceptable, Good, Best)
Trial Locations
- Locations (1)
Jin-Tae Kim
🇰🇷Seoul, Korea, Republic of