MedPath

Biting Force and Chewing Efficiency of Complete Dentures.

Not Applicable
Completed
Conditions
Biting
Chewing Problem
Interventions
Other: conventional complete denture
Other: CADCAM 3D printed denture
Other: CAD/CAM milled denture
Registration Number
NCT04793503
Lead Sponsor
Kafrelsheikh University
Brief Summary

The aim of this study was to compare the MBF and chewing efficiency of complete denture bases fabricated by conventional, 3D printing and milling techniques. The research hypothesis was that, there are no significant differences in MBF and chewing efficiency in complete dentures fabricated by the three methods.

Detailed Description

Participant selection and treatment This study will include a clinical experiment with a cross-over clinical trial design. For this study, 27completely edentulous participants with age range of 50-65 were selected from the outpatient clinic of the Removable Prosthodontic Department, Faculty of dentistry, Kafr Elsheikh University, Egypt. All participants had Angle class I jaw relation maxillomandibular relationship, normal alveolar ridge volume, no temporomandibular joint disorders, no heart disease, and no systemic diseases that affect the complete denture treatment procedures.

To reduce the effect of order of treatment on MBF, were successively given the following prosthesis i) complete dentures fabricated by the conventional technique ii) 3D printed complete dentures iii) milled complete dentures in a random order.

Construction of the CADCAM 3D printed denture The same steps of the conventional technique will be performed till the adjustment of occlusion rims then in the dental laboratory, the maxillary and mandibular definitive casts and the occlusal rims will be prepared for scanning with scan spray. Scanning will be performed with an optical 3D scanner . The files from the laser-scan will be translated into stereolithography (STL) files and the CDs are virtually designed in ExoCad software. After minor modifications in the positions of teeth were made, fabrication of the dentures will be approved and the digital denture base will be fabricated using 3D printing technique from Dental Pink resin

Construction of the CAD/CAM milled denture Once the complete denture has been virtually designed in CAD software (ExoCad software) a preview will be sent for evaluation using 3D viewing software. After minor modifications in the positions of teeth were made, fabrication of the dentures will be approved. The digital denture will be fabricated by the command software of the milling machine (ExoCad 5x milling machine) from prepolymerized resin acrylic pucks and the teeth (TSM Acetal Dental) were milled into template .After that the denture will be finished and polished according to the traditional procedures For all groups, after placement, clinical evaluations of the fit, retention, stability, occlusal relationship, esthetics, and phonetics were performed. Assessment of the occlusion was made with articulating paper, chairside adjustments were made and premature contacts were corrected. The patient was given a proper program for denture insertion and oral hygiene measures.

Assessment of biting force

* This will be made by using a custom-made device composed of Flexiforce A 301® force sensor and Arduino microcontroller with a crystal display. The sensor is calibrated by known weight object for several times, and the sensor is covered by 3 mm layer of putty rubber base material.

* Readings will be performed at 1 week, 1 month and 3 months follow-up periods. Assessment of chewing efficiency The chewing efficiency will be evaluated according to the procedure described by Schimmel et al. (2007) using a chewing gum. Specimens will be prepared from two colored gums one with the flavor "Sour Berry" (white color) and the other with the flavor "Fancy Fruit" (orange color). Two strips of a standard size (30 9 18 9 3 mm) will be cut from each gum and manually stuck together. Patients will be instructed to chew five samples of gum on their preferred chewing side for 5, 10, 20, 30 and 50 cycles, respectively. Between the different tests, an interval of at least 1 min will be imposed to reduce the effect of fatigue. The total duration of the experiments was approximately 8 min.

After chewing, the samples will be then spat into transparent plastic bags, which The samples will be then scanned from both sides with a of resolution 500 dots per inch. The numbers of selected pixels will be recorded from the histogram for each side, and mean of those figures will be calculated. To assess the reproducibility of chewing, the subjects will be available to repeat the experiments on a different day.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
27
Inclusion Criteria
  • Angle class I jaw relation maxillomandibular relationship
  • Normal alveolar ridge volume
  • No temporomandibular joint disorders
  • No heart disease
  • No systemic diseases that affect the complete denture treatment procedures
Exclusion Criteria
  • Abnormal jaw relation
  • TMJ disorders
  • Any systemic disease interfering with complete denture treatment

Study & Design

Study Type
INTERVENTIONAL
Study Design
CROSSOVER
Arm && Interventions
GroupInterventionDescription
conventional complete dentureconventional complete denturethe patients receive conventional complete denture constructed from heat cure acrylic resin
CADCAM 3D printed dentureCADCAM 3D printed denturethe patients receiveCADCAM 3D printed denture constructed by using printing machine
CAD/CAM milled dentureCAD/CAM milled denturethe patients receiveCADCAM 3D printed denture constructed by using milling machine
Primary Outcome Measures
NameTimeMethod
biting forceReadings will be performed baseline 1 week after denture insertion then 1 month after denture insertion then 3 months after denture insertion.

- This is done custom-made device composed of Flexiforce A 301® force sensor and Arduino microcontroller with a crystal display. The sensor is calibrated by known weight object for several times, and the sensor is covered by 3 mm layer of putty rubber base material.

• The device was placed between the upper and lower first molar. The patient then was instructed to bite as hard as possible for a period of 3 s three times in succession, with at least 20 s of resting between each bite. The readings were recorded, and the average bite force was calculated

Secondary Outcome Measures
NameTimeMethod
chewing efficiency3 months after denture insertion

Specimens will be prepared from two colored gums one with the flavor "Sour Berry" (white color) and the other with the flavor "Fancy Fruit" (orange color). Two strips of a standard size (30 9 18 9 3 mm) will be cut from each gum and manually stuck together.

Trial Locations

Locations (1)

Faculty of Dentistry , Kafr El Shiekh University

🇪🇬

Kafr Ash Shaykh, Egypt