跳至主要内容
临床试验/NCT04803331
NCT04803331Unknown不适用

Superparamagnetic Iron Oxide-enhanced Magnetic Resonance Imaging for Sentinel Lymph Node Identification in Oral Cancer: a Feasibility Study

Radboud University Medical Center2 个研究点 分布在 1 个国家目标入组 10 人开始时间: 2021年7月27日最近更新:
适应症

试验速览

阶段
不适用
入组人数
10
试验地点
2
主要终点
MR (artefact) finetuning for optimization of SPIO dose and timing of MRI

研究概览

简要总结

To explore the feasibility of sentinel lymph node identification by SPIO injection followed by MRI in head-and-neck cancer patients.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Male or female aged >18 years.
  • Patients with histopathologically proven cT1-2N0M0 squamous cell carcinoma of the oral cavity.
  • Patients planned to undergo routine sentinel node biopsy with 99mTc-radioisotope and SPECT-CT.
  • Patient provided written informed consent.

排除标准

  • Patients who underwent previous surgery or radiotherapy to the neck.
  • Contra-indications to SPIO (Hypersensitivity to iron oxide or dextran compounds, Presence of iron overload disease (hereditary hemochromatosis, hemosiderosis, chronic hemolytic anemia (e.g. thalassemia, sickle cell anemia))
  • Contra-indications to MRI: Epilepsy, Claustrophobia, Metallic splinters, Pacemaker, pacemaker wires or implanted defibrillator, Implanted magnets in jaw, Metallic Arterial clips (carotid arteries), Pregnancy, Auditory implant, neurogenic bladder stimulator, insulin pump, neurostimulator, baclofen pump, Metallic tissue expander after mastectomy, Cochlear implant, Metallic braces, Other foreign bodies implanted
  • Unable to provide informed consent.

结局指标

主要结局

MR (artefact) finetuning for optimization of SPIO dose and timing of MRI

时间窗: 2 months

The first two patients will receive a dose of 0.012 ml SPIO. MR-images will be assessed. If this dose provides satisfactory MR-images (good visualization of lymph nodes without disturbing artefacts), subsequent patients will receive the same dose. If the artefact is too large, the dose will be decreased. If visualization is poor, the dose will be increased. The procedure will be repeated with adjusted doses each time in two patients until satisfactory MR-images are obtained. The investigators have established timing of MRI 1 hour after SPIO injection. It is assumed that after this time interval SPIO particles have had sufficient time to migrate to the SNs and to be taken up. However, if this interval appears to be too long because 'too many' SNs are visualized the time interval will be shortened. If this interval appears to be too short since no or too little SNs are visualized because SPIO uptake has not taken place yet, the time interval will be lengthened.

次要结局

  • Comparison of SPIO distribution within a lymph node on MR-images and histopathological staining.(1 year)
  • Localization of sentinel lymph nodes detected by conventional 99mTC-nanocollloid injection and SPECT-CT and by SPIO injection and MRI(1 year)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验