MedPath

Comparison of Autologous Serum Versus Preservative Free Artificial Tear

Phase 4
Completed
Conditions
Dry Eye
Interventions
Drug: Preservative free artificial tears(Tears naturale free, Refresh single dose eye drop)
Drug: %40 diluted Autologous serum
Registration Number
NCT02752763
Lead Sponsor
Niğde State Hospital
Brief Summary

Dry eye is a significant adverse effect of isotretinoin causing patients to use ophthalmic medications. For this reason, many patients using isotretinoin are referred to ophthalmology clinic because of discomfort symptoms. In the literature, there are studies suggesting superiority of Autologous serum drops regarding effects on ocular surface when compared to artificial tear. In addition, Autologous serum was also used in several corneal pathologies with successful outcomes. No data regarding use in the ocular adverse effects of isotretinoin was found in the literature; however, investigators think that it may be an effective alternative in the treatment of dry eye developed during isotretinoin use due to positive effects on ocular surface, epithelial regeneration and anti-inflammatory effect. Autologous serum can be a choice of ophthalmologists in routine practice by increasing number of comprehensive studies investigating effectiveness, safety and long-terms effects of Autologous serum therapy.In this study, it was aimed to investigate dry eye development in the patients receiving systemic retinoic acid therapy and to compare effectiveness of Autologous serum and Preservative free artificial tear in the patients with dry eye disease.

Detailed Description

This prospective, cross-sectional, double blind study was conducted by Ophthalmology Clinic on patients who have drye eye due to systemic isotretinoin treatment for several reasons in Niğde State Hospital between October, 2015 and March 2016. Patients determined as having drye eye during systemic isotretinoin treatment were included to our study. At baseline, 1.and 2. month of study, detailed ocular examination, best corrected visual acuity measurement, intraocular pressure measurement, Tear Break-Up time(TBUT)(5 µL of fluorescein sodium 2 % eye drops was used per each measurement using a pipette for standardization, and the mean value of two readings per patient was recorded) and Schirmer Test I (ST I) without topical anesthesia were performed. Effect on daily life was assessed by using Ocular Surface Disease Index (OSDI) score. TBUT\<10 seconds, ST I \<10 mm without local anesthesia, corneal and conjunctival staining was interpreted in favor of dry eye. In the follow-up period, investigators investigated the efficacy of autologous serum eye drops for the patients having dry eye illness during isotretinoin treatment. After informed consent, peripheral venous blood (14-20 ml) was drawn from antecubital vein of patients to prepare AS. Blood sample was left at room temperature over 2 hours for clotting. Serum was obtained after centrifugation at 4000 revolutions per minute (rpm) for 10 minutes at 4 °C using a centrifugal device(Nuve NF1200R). Next, in a laminar flow cabinet under sterile conditions, approximately 10 mL of supernatant was collected and diluted to 40 % with isotonic (0.9 % NaCl) saline solution and then 25 mL of preparation was aliquoted into 1.5-mL Eppendorf vials, each of which was wrapped with aluminum foil by the other specialist(Erkut Küçük) for protection against ultraviolet light (to prevent vitamin A degradation), and blinding the patients to the treatment. PFAT eye drops were also placed into different 1.5-ml Eppendorf vials and likewise wrapped with aluminum foil by the other specialist(Erkut Küçük) for blinding the patients. The droppers were also wrapped with aluminum foil for further blinding the patient while applying the eye drops. Patients were randomised via assigned laterality numbers and sealed regime envelopes by the other specialist(Erkut Küçük). Preservative-free isotonic saline was used for washout for 2 weeks prior to beginning of the study.

After the first treatment period (1 month) all patients underwent a 2-week washout period with isotonic saline (0.9 % NaCl) eye drops. Ten a new set of vials (AS or PFAT) was assigned to each patient by the other specialist(Erkut Küçük) for the second treatment period.

After the first 1-month treatment period, patients who had conventional PFAT treatment were switched to AS treatment and the patients who had AS treatment in the first 1-month treatment period were switched to conventional PFAT treat- ment in the second 1-month treatment period, according to the study's crossover nature. The examining ophthalmologist (Uğur Yılmaz) that performed tear function and ocular surface evaluations was blinded to the type of eye drops given to each patient. In addition, the patients were blinded to which treatment they were receiving.

Only the Other specialist (Erkut Küçük), who was not responsible for patient evaluation, knew which patient received which treatment during study periods. All patients were instructed to keep the vials (containing either AS or PFAT) in a refrigerator at 4 °C. All patients were advised to change the vial every other day during the treatment period. TBUT and ST I were administered by the same ophthalmologist (Uğur Yılmaz).

The study was approved Institutional Review Board of Erciyes University, Medicine School. The study was conducted in accordance to Helsinki Declaration. All patients gave written informed consent.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
24
Inclusion Criteria

Not provided

Exclusion Criteria
  • corneal pathologies such as dry eye illness before isotretinoin treatment
  • previous cornea surgery, injury or keratitis
  • active ocular infection
  • meibomian gland dysfunction
  • excessive allergic reaction that may be associated with dry eye
  • glaucoma therapy use
  • severe anemia
  • previously use of PFAT or AS for any reason
  • (Hb<10 g/dL) and elevated hepatic function tests requiring withdrawal of therapy

Study & Design

Study Type
INTERVENTIONAL
Study Design
CROSSOVER
Arm && Interventions
GroupInterventionDescription
preservative free artificial tear dropPreservative free artificial tears(Tears naturale free, Refresh single dose eye drop)preservative free artificial tears drop is a drop group declaring different kind of active agent like hydroxypropyl methylcellulose, carboxymethyl cellulose etc commonly used in dry eye treatment. Preservative free artificial tear( carboxymethyl cellulose, hydroxypropyl methylcellulose) was used as four times one drop daily. In our study, we prescribed to patients preservative free artificial tears drop(hydroxypropyl methylcellulose or carboxymethyl cellulose) four times one drop daily.
%40 Autologous serum(AS)%40 diluted Autologous serumperipheral venous blood (14-20 ml) that drawn from antecubital vein of patients to prepare Autologous Serum. Blood sample was left at room temperature over 2 hours for clotting. Serum was obtained after centrifugation at 4000 revolutions per minute (rpm) for 10 minutes at 4 °C using a Nuve NF1200R. Next, in a laminar flow cabinet under sterile conditions, approximately 10 mL of supernatant was collected and diluted to 40 % with isotonic saline solution. It is recommended for dry eye diseases, too. %40 diluted Autologous Serum used as four times one drop daily.
Primary Outcome Measures
NameTimeMethod
Change in Schirmer Test I in Patients with Dry Eye due to isotretinoin use after autologous serum or preservative free artificial tears treatmentup to 3 Months monthly measurements were done

Schirmer Test I is used for Dry Eye evaluation before and after autologous serum or preservative free artificial tears treatment. Schirmer test is used to measure tear secretion. Schirmer strips are used for this test. Wetting of the paper is recorded in millimeter

Change in Break up Time in Patients with Dry Eye due to isotretinoin use after autologous serum or preservative free artificial tears treatmentup to 3 Months monthly measurements were done

fluorescein sodium eye drops was used for measurement of Break up Time. Value of Break up Time for per eye is recorded as seconds

Change in Ocular surface Disease Index in Patients with Dry Eye due to isotretinoin use after autologous serum or preservative free artificial tears treatmentup to 3 Months monthly measurements were done

OSDI score is a reliable and feasible test which is commonly used for dry eye patients to grade either dry eye symptom severity and its effect on vision-related function. In this index, people are asked to indicate whether they experienced any of the symptoms or problems due to drye eye, if so, how often. Every question asked to patients is scored from one to four according to the frequency of symptoms. The scores were collected from all the questions.

Secondary Outcome Measures
NameTimeMethod

Trial Locations

Locations (1)

Niğde State Hospital

🇹🇷

Niğde, Turkey

© Copyright 2025. All Rights Reserved by MedPath