跳至主要内容
临床试验/NCT01443767
NCT01443767已完成不适用

Pilot Study to Examine the Correlation of 'Estimated Continuous Cardias Output' (esCCO) With Pulse Contour Analysis of the Arterial Waveform (Picco) in Partial Liver Resection

Heidelberg University1 个研究点 分布在 1 个国家目标入组 27 人开始时间: 2011年7月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
27
试验地点
1
主要终点
Correlation of esCCO and Picco in Partial Liver Resection

研究概览

简要总结

The purpose of this study is to determine the measuring accuracy of the truly non-invasive method estimated continuous cardiac output (esCCO) against the reference method pulse contour analysis of the arterial waveform (Picco) in partial liver resection. esCCO is calculated using the pulse wave transit time, which is defined as the time between the R-wave of the ECG and a 30% increase of the differentiated pulseoximetry waveform.

详细描述

The objective is to compare two methods of cardiac output measurement: the new non-invasive method called esCCO™ (by Nihon Kohden, Tokyo, Japan) and the established more invasive method PiCCO™ (by PULSION Medical Systems, Munich, Germany). esCCO™ is a completely non-invasive method that could provide a cardiac output measurement in a large range of patients because of an extremely low risk benefit balance. Thus the valuable information of cardiac output in combination with standard patient monitoring could be integrated in the assessment and clinical handling of a patients circulatory system.

In previous Japanese studies, esCCO™ was tested against the pulmonary artery catheter in patients undergoing heart surgery. Because of promising results in those studies, the validity of the method is now tested in patients scheduled for partial liver resection as a major visceral surgery intervention. Partial liver resection is a medium to high risk surgical intervention because of the extended blood supply of the organ. High and sudden blood loss can easily occur during the operation. Measurement period starts at the beginning of anesthesiologic induction and is continued until the extubation at the end of the intervention.

The algorithm for esCCO™ -measurement is integrated in an approved patient monitor that replaces the standard patient monitor during the measurement-period. The PiCCO™-device is added on the same rack and a cable connects the PiCCO™-device to the patient monitor. To assure maximum quality of the reference method, a thermodilution for PiCCO™-calibration is accomplished every 30 minutes.

In the study protocol, events like esCCO™ - and PiCCO™-calibration time, catheter positioning time, changes of the patient's position, ventilation settings, volume in- and output and drug administration, patients's data and diagnoses are logged. Vital parameters from the patient monitor including the PiCCO™-cardiac output values are recorded every second in real time on a study laptop mounted on the same rack as the patient monitor and the PiCCO™ device but separated electrically from the other devices.

A total of 30 patients shall be investigated in the study during a planned study time of approximately 6 months. The ethics committee of the University of Heidelberg gave their consent to the study (S-188/2011). The investigators will approximately receive 1080 data pairs when averaging the values every 5 minutes with a mean duration of the surgical procedure of 3 hours.

研究设计

研究类型
Observational
观察模型
Case Only
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • written consent
  • patient scheduled for partial liver resection
  • sinus rhythm

排除标准

  • no written consent
  • continuous severe cardiac arrhythmias
  • cardiac pacemaker
  • intraaortal balloon pump

结局指标

主要结局

Correlation of esCCO and Picco in Partial Liver Resection

时间窗: Intraoperative (Measurement from induction of anaesthesia to extubation)

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Christoph Schramm, M.D.

Principal Investigator

Heidelberg University

研究点 (1)

Loading locations...

相似试验