Skip to main content
Clinical Trials/NCT04039256
NCT04039256UnknownNot Applicable

Efficacy And Safty of Heartech® Left Ventricular Partitioning Device In Treating Heart Failure Post Myocardial Infarction (Phase II Clinical Trial: The Partical Study)

Shanghai Jiao Tong University School of Medicine1 site in 1 country117 target enrollmentStarted: January 2, 2020Last updated:
Conditions
Interventions

Trial Snapshot

Phase
Not Applicable
Sponsor
Enrollment
117
Locations
1
Primary Endpoint
Incidence of MACCE [primary safety]

Study Overview

Brief Summary

This is a prospective, multi-center, single-group, target-value clinical study. The primary safety end points are major adverse cardiovascular events (MACCE) 30 days after device implantation.

The primary efficacy end point is the end of left ventricular systolic volume index (LVESVI) reduction at 6 month.

The secondary observational end points includes immediate success rate of the procedure, all-cause mortality, cardiac death, rehospitalization rates and MACCE occurrence rate within 12 month. Besides, left ventricular end systolic volume index (LVESVI) change at 30 days,12 months, left ventricular ejection fraction (LVEF), left ventricular end-diastolic volume index (LVEDVI), 6 minutes walk test, heart function evaluation (NYHA classification) and quality of life (EQ-5D) at 30 days, 6 months, 12 months will also be evaluated.

After statistical hypothesis and sample size estimation, the sample size of this clinical trial was 117 cases. All subjects were followed up 30 days, 6 months and 12 months after implantation of the Heartech® left ventricular partitioning device. All relevant clinical data were managed by professional data management center, and all relevant clinical data were statistically analyzed by third-party statistical center.

Detailed Description

MACCE includes all-cause death, myocardial infarction, stroke and any elective or emergency cardiac or thoracic aortic surgery or catheter-based interventional therapy.

Study Design

Study Type
Interventional
Allocation
Na
Intervention Model
Single Group
Primary Purpose
Treatment
Masking
None

Eligibility Criteria

Ages
18 Years to 80 Years (Adult, Older Adult)
Sex
All
Accepts Healthy Volunteers
No

Inclusion Criteria

  • •left ventricular ejection fraction ≤45% and ≥20%;
  • •patients with left ventricular end-systolic volume index (ESVI) ≥50mL/m2;
  • •transthoracic ultrasound showed contradictory motion of the left ventricle after myocardial infarction;
  • •60 days prior to anterior wall myocardial infarction with ischemic heart failure (NYHA grade II to "not hospitalized" grade IV);
  • •the left ventricle must have the appropriate anatomic structure (size and shape) which is confirmed by cardiac CT and left ventricular angiography to implant the appropriate Heartech® device;
  • •agree to receive reasonable treatment according to current ACC/AHA and Chinese guidelines for heart failure diagnosis and treatment;
  • •the subjects or their legal representatives are informed of the nature of this study and agree to participate in all the terms of this study, sign the informed consent approved by the ethics committee, agree to accept the postoperative treatment plan and follow-up requirements, and can complete the examination of follow-up.

Exclusion Criteria

  • •patients whose left ventricular anatomy is not suitable for Heartech® occlusal device implantation;
  • •the abnormal ventricular wall movement not contains the anterior wall of the left ventricle, the apex of the left ventricle and the ventricular septum;
  • •patients with thrombosis in the left ventricle;
  • •mitral stenosis or regurgitation (tricuspid, aortic or mitral) > 2+ (moderate);
  • •recent (within 6 month) cerebrovascular accident (CVA) or transient ischemic attack (TIA);
  • •end-stage renal disease requiring long-term dialysis, episodic sepsis or active phase endocarditis;
  • •life expectancy at admission < 1 year;
  • •known allergy to aspirin, heparin, warfarin, Nitinol (alloys of titanium and nickel) or contraindications, or sensitivity to contrast agents;
  • •cardiogenic shock occurred within 72 hours before procedure;
  • •pregnancy or planned pregnancy during the study period;
  • •participated in clinical trials of other drugs or medical devices during the same period;
  • •the researcher judged that the patient had poor compliance and could not complete the study as required;
  • •other conditions considered unsuitable for participation in this clinical trial.

Arms & Interventions

PVR implantation group

Experimental

Patients enrolled receive PVR intervention

Intervention: percutaneous ventricular restoration using heartech® device (Device)

Outcomes

Primary Outcomes

Incidence of MACCE [primary safety]

Time Frame: 30 days

major adverse cardiovascular events (MACCE)

LVESVi Reduction [primary efficacy]

Time Frame: 6 month

left ventricular systolic volume index (LVESVi) reduction

Secondary Outcomes

  • Procedure Success(immediate)
  • Rehospitalization(12 month)
  • Mortality(12 month)
  • Cardiac death(12 month)
  • Incidence of MACCE(12 month)
  • LVESVi Reduction(12 month)
  • LVEF change(12 month)
  • life quality(12 month)
  • LVEDVi Reduction(12 month)
  • Cardiac function(12 month)
  • Walk tolerance(12 month)

Investigators

Sponsor
Shanghai Jiao Tong University School of Medicine
Sponsor Class
Other
Responsible Party
Principal Investigator
Principal Investigator

Zhang Qi, MD

Chief of Cardiology Department, Rui Jin Hospital

Shanghai Jiao Tong University School of Medicine

Study Sites (1)

Loading locations...

Similar Trials

Phase II Clinical Trial of Percutaneous... | Clinical Trial