Laser-excimer Versus High-pressure Dilation to Treat Under-expansion of the Stent (LASER EXPAND Study)

Fundación EPIC6 个研究点 分布在 1 个国家目标入组 31 人开始时间: 2020年9月12日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
31
试验地点
6
主要终点
Variation of the minimum luminal area (MLA)

研究概览

简要总结

The laser-excimer technology could be an essential tool to correct the under-expansion of the stent once it has been implanted unless severe calcification. The laser-excimer technology achieves a greater minimum luminal area when treating an infra-expanded stent, when compared with the results obtained with the simple dilatation at high or very high pressure.

详细描述

The laser-excimer technology could be an essential tool to correct the under-expansion of the stent once it has been implanted unless severe calcification.

The investigators propose a study that serves as proof of concept for this technology (laser Excimer) used according to its intended use in this specific substrate of coronary lesions. (stent under-expansion without severe underlying calcification).The laser-excimer technology achieves a greater minimum luminal area when treating an infra-expanded stent, when compared with the results obtained with the simple dilatation at high or very high pressure.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •Patients with:
  • •Age ≥ 18 years.
  • •Consecutive real-world patients, referred for cardiac catheterization for any cause, who present in any main vessel, bypass or in the common trunk an under-expanded stent tributary of being treated (minimum luminal area <4 mm2 or <6 mm2 in the left main coronary artery measured by IVUs (Intravascular Ultrasound) / OCT(Optical Coherence Tomography)) and that it is not possible to dilate with a NC balloon to a maximum of 20 atm.

排除标准

  • •Refusal of the patient to participate in the study.
  • •Patients with life expectancy <1 year.
  • •Patients with advanced kidney disease (grade IV) or liver failure (Child C)

研究组 & 干预措施

Stent under-expansion with NC Balloon

Other

干预措施: NC ( Non- Compliant) Balloon dilatation (Procedure)

Stent under-expansion with Laser Excimer + NC Balloon

Other

干预措施: Laser Excimer + NC Balloon (Procedure)

结局指标

主要结局

Variation of the minimum luminal area (MLA)

时间窗: During procedure

Detection of rate for Variation of the minimum luminal area (MLA) of the under-expanded stent defined as: ((MLAfinal-MLAinicial) / MLAinicial) x 100.

次要结局

  • Complications during procedure(During procedure)
  • Tachycardia(During procedure)
  • Hyperacute thrombosis (THA)(During procedure)
  • Contrast Volume(During procedure)
  • Periprocedural Infarction complications(During procedure)
  • No- Reflow/Slow Flow (SFL)(During procedure)
  • Bradycardia(During procedure)
  • Procedure time(During procedure)

研究者

发起方
Fundación EPIC
申办方类型
Other
责任方
Sponsor