Skip to main content
Clinical Trials/NCT06548087
NCT06548087CompletedNot Applicable

Use Of Gigstride Device In Patients With Lower Extremity Deficit

Johns Hopkins University1 site in 1 country44 target enrollmentStarted: October 8, 2024Last updated:
Conditions
Interventions

Trial Snapshot

Phase
Not Applicable
Status
Completed
Enrollment
44
Locations
1
Primary Endpoint
Device Feasibility as assessed by ambulatory device aid score

Study Overview

Brief Summary

For patients with lower extremity deficits, the investigator(s) would like to assess implementing use of Gigstride ambulatory device to assess the following:

  • Patient satisfaction with use of ambulatory device
  • Effects of Gigstride device utilization on kinetics, biomechanics
  • Effects of Gigstride device utilization on walking speed, stair speed, stability

Detailed Description

The Gigstride ambulatory device is a novel product that can possibly be used as an alternative ambulatory aid.

  • The Gigstride Wearable trainer is a flexible device anchored at distal points in the body. Reciprocating elastic cords follow a path through engineered guides that surround and engage the core, enhance hip and knee flexion, and improve balance. It uses the body's own structure to create symmetry, each step creates momentum and lift, users report feeling lighter, stronger, straighter, and more stable. The gentle, adjustable pressure provides alignment and proprioceptive input that allows for neuromuscular re-education.
  • The cords can be configured to target specific therapeutic goals. The two larger diameter cords are used for hip and knee flexion, attaching to the medial and lateral aspect of the shoe at an eyelet near the malleolus. The two smaller diameter cords are used for Foot Drop and attach to the medial and lateral eyelets at the distal part of the shoe, supporting dorsiflexion. In-toeing and out-toeing can be mitigated by attaching both cords either medially or laterally to gently align the foot.
  • The Gigstride wearable is a working prototype that can be fitted to almost anyone.

This research is being done to investigate the effectiveness of the Gigstride ambulatory device among individuals who have undergone prior treatment for a lower extremity mobility deficit, with one of the following causatives "Principal Diagnoses": Osteoarthritis hip, knee, spine, Pre or post hip replacement, Pre or post knee replacement, Multiple Sclerosis, Mild to moderate central spinal stenosis, Foot drop, Degenerative changes, not otherwise specified, Balance issues. The patient would have to be seen by physical therapy and recommended cane, brace, walker, Ankle Foot Orthoses, or electronic or robotic device for management.

For patients who are scheduled to be seen by the investigator in clinic with one of the above diagnoses, and recommended to use some type of ambulatory aid, the investigator will offer the Gigstride ambulatory device as an alternative and inquire about the patient's interest in participating in the study. After choosing to be a part of the study, the patients will use Gigstride device to perform the following tasks:

  • Walk a different distances to assess speed and fatigue
  • Perform functional mobility tasks (sit-to-stand, stand-to sit, stand-pivots, etc.)

Study Design

Study Type
Interventional
Allocation
Na
Intervention Model
Single Group
Primary Purpose
Device Feasibility
Masking
None

Eligibility Criteria

Ages
18 Years to — (Adult, Older Adult)
Sex
All
Accepts Healthy Volunteers
No

Inclusion Criteria

  • •Male or female, age > 18
  • •Has undergone treatment for a lower extremity mobility deficit, with one of the following causatives Principal Diagnoses Osteoarthritis hip, knee, spine Pre or post hip replacement Pre or post knee replacement Multiple Sclerosis Mild to moderate central spinal stenosis Foot drop Degenerative changes, not otherwise specified Balance issues
  • •Recommended cane, brace, walker, Ankle Foot Orthoses, or electronic or robotic device for management
  • •Provide written consent for participation.
  • •Ability to wear shoes with laces

Exclusion Criteria

  • •Inability to walk.
  • •Shoulder operation within 1 year preceding the study date.
  • •Injury due to a work accident (e.g. workers comp)
  • •Higher functions do not enable proper comprehension of protocol or reliable data recording.

Arms & Interventions

Use of Gigstride Ambulatory Device

Experimental

The participant will be use the Gigstride ambulatory device to perform the following tasks:

  • Walk a different distances to assess speed and fatigue
  • Perform functional mobility tasks (sit-to-stand, stand-to sit, stand-pivots, etc.)

The participants will then be asked to fill out a questionnaire, "Gigstride Clinical Trial Questionnaire" that will be used for qualitative data, such as ease of use and comfortability with using the device.

The overall amount of time for the evaluation and questionnaire will take approximately 30 minutes to 1 hour.

Intervention: Gigstride Ambulatory Device (Device)

Outcomes

Primary Outcomes

Device Feasibility as assessed by ambulatory device aid score

Time Frame: 1 year

The investigators will assess the participants comfort and ease of use of the proposed device with a questionnaire that consists of 11 questions in a likert scale. 1 = strongly agree to 5 = strongly disagree. Lowest score of 11 = participant agrees that the device is a feasible option as an ambulatory aid. Highest score of 55 = participants disagree that the proposed device can be used as an ambulatory aid.

Secondary Outcomes

No secondary outcomes reported

Investigators

Sponsor Class
Other
Responsible Party
Sponsor

Study Sites (1)

Loading locations...

Similar Trials