Accuracy, Safety and Diagnostic Outcome of Percutaneous Fluoroscopic vs. CT Guided Transpedicular Core Needle Biopsy for Spinal Infections and Tumors. A Prospective Randomized Trial
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 60
- 试验地点
- 2
- 主要终点
- Diagnostic accuracy of fluoroscopic and CT guided spinal biopsy
研究概览
简要总结
Spinal biopsy is important to obtain culture and histopathological diagnosis in spine infection and tumors. To date, there is no prospective randomized study comparing both techniques. Therefore, the aim of this prospective randomized trial was to evaluate the accuracy, safety and diagnostic outcome of both these techniques.A prospective randomized trial was performed in 60 patients divided equally into fluoroscopic and CT guided spinal biopsy groups. Transpedicular approach was done with 8G core biopsy needle. Specimens were sent for histopathological examinations and cultures. Diagnosis were made based on biopsy results, clinical criteria and disease progression during 6 months follow up. Radiation expose to patients and doctors were measured with optically stimulated luminescence dosimeters (OSLDs).
详细描述
This prospective randomized study was carried out in a single institution from November 2016 to June 2018.
Patients were recruited by three spine surgeons from the same institution after eligibility assessment. Sixty consecutive patients were randomized equally into fluoroscopic and CT guided spinal biopsy groups. Randomization procedure was performed using a computer generated random number sequence on www.random.org. Separate individuals completed the random allocation sequence, patient enrollment and outcome assessment. Outcome assessors were blinded to group assignment.
Data collection Clinical data collected were: patient demographics, comorbidities, infective parameters, tumor markers, Magnetic Resonance Imaging (MRI) findings and pre-biopsy pain score at rest using visual analogue scale (VAS). Intraoperative data included radiation exposure dosage, biopsy duration and complications encountered. Following biopsy, we recorded the biopsy result, 6-hourly pain score (VAS) at for 48 hours, additional analgesia requirement and complications.
Radiation measurement Commercial optically stimulated luminescence dosimeters, OSLDs (NanoDotTM Dosimeter, Landauer Inc, Glenwood, IL) were used to measure radiation dose. Ten OSLDs were placed on patients and doctors prior to all biopsies over selective areas representing radiosensitive organs. Placements of the OSLDs were done by a single observer. OSLDs were processed using MicroStar OSLD reader system (Landauer, Inc. Glenwood, IL). Each OSLD was processed 3 times during each reading to obtain a mean value to minimize error. The absorbed doses were measured in centigrays (cGy). Bleaching/zeroing of the OSLDs were done using optical annealing system containing fluorescent lamps (Osram lumilux, 24 W, 280 ~780 nm) in between each use of OSLDs.
Biopsy technique Transpedicular approach with an 8-gauge T-Lok™ bone marrow biopsy needle (Argon Medical Devices, Athens, TX, USA) was used in both arms. 10cc 2% lignocaine was infiltrated prior to biopsy. Biopsy needle was tapped gently with mallet through the pedicle and into the lesion under imaging guidance. Trocar was then withdrawn once it reached the affected area. The cannula was rotated several times to disengage sample from surrounding tissue. Then, aspiration of samples was done using 10-ml syringe prior to retraction of the cannula. Tissue samples were retrieved from the cannula with the use of stylet.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Diagnostic
- 盲法
- Single (Outcomes Assessor)
盲法说明
Separate individuals completed the random allocation sequence, patient enrollment and outcome assessment. Outcome assessors were blinded to group assignment.
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Age more than 18;
- •Patients who presented with clinical symptoms and radiological features suggestive of infection or malignancy;
- •MRI reported as probable infection or tumour.
排除标准
- •Cervical spine lesion;
- •Significant neurological deficit that required urgent surgery;
- •Partially treated spinal infections;
- •Vascular tumour;
- •Infection over skin puncture site;
- •Bleeding diathesis;
- •Medically unfit for spinal biopsy.
研究组 & 干预措施
Fluoroscopy Guided Spinal Biopsy Arm
Fluoroscopy guided spinal biopsies were done by spine surgeons in the operation theatre using C-Arm fluoroscopy device (OECFluorostar7900Compact - GE®). C-arm image intensifier was positioned until fluoroscopic beam was collinear with the corresponding vertebral body on AP view prior to insertion of biopsy needle
干预措施: Fluoroscopy Guided Spinal Biopsy (Diagnostic Test)
CT guided Spinal Biopsy Arm
CT guided spinal biopsies were done by radiologist under guidance of 128-slice CT scanner (SOMATOM Definition AS+, Siemens Medical Solutions USA, Inc.). Preliminary axial CT scanning was done in bone window (window width, WW:2500; window level, WL:500) at the pre-selected levels decided from previous imaging to plan the needle access. Biopsy was then performed under sequential CT-fluoroscopy scan.
干预措施: CT guided Spinal Biopsy (Diagnostic Test)
结局指标
主要结局
Diagnostic accuracy of fluoroscopic and CT guided spinal biopsy
时间窗: 6 months
Diagnostic accuracy were determined based on true positive, true negative, false positive and false negative biopsy findings
次要结局
- Radiation expose to patients and doctors(During biopsy)
- Pre biopsy and post biopsy pain score assessed by visual analogue scale (VAS)(48 hours post biopsy)
- Complications of spinal biopsy(During and 48 hours after spinal biopsy)
研究者
Dr Lee She Ann
Orthopedic Registra
University of Malaya