MVT-100: Advancing the Clinical Use of Perflutren Ultrasound Contrast Agents for Suboptimal Echocardiograms

Microvascular Therapeutics, LLC2 个研究点 分布在 1 个国家目标入组 16 人开始时间: 2019年4月25日最近更新:
适应症
干预措施
相关药物

试验速览

阶段
1 期
状态
已完成
入组人数
16
试验地点
2
主要终点
Oxygen Saturation

研究概览

简要总结

Definity (perflutren lipid microspheres, Lantheus Medical Imaging) is an ultrasound contrast indicated for use in patients with suboptimal echocardiograms to opacify the left ventricular chamber and to improve the delineation of the left ventricular endocardial border. MVT-100 (the investigational pharmaceutical) is similar to Definity, with the exception of the removal of one lipid in the lipid blend and substitution of another lipid. This study is intended to evaluate the safety and efficacy of MVT-100 using a single ascending dose design in healthy volunteers. Patients are randomized to receive either MVT-100 or Definity and undergo echocardiograms after receiving either MVT-100 or Definity via bolus or IV infusion administration. The primary endpoints evaluated are safety and endocardial border delineation.

详细描述

Ultrasound is one of the most common imaging examinations and has advantages of absence of ionizing radiation, portability and relatively low cost. Ultrasound contrast agents are used to improve the accuracy of ultrasound and Definity (perflutren) is the world's leading ultrasound contrast agent but perflutren has to be refrigerated and has a side effect of back pain. The investigators have developed a new, improved perflutren, MVT-100, with potential for room temperature storage.

Ultrasound contrast agents are used to increase the backscatter (signal intensity of blood vessels and tissues to improve diagnostic accuracy) of ultrasound imaging. In the US ultrasound contrast agents are FDA approved for echocardiography to improve endomyocardial border definition.

MVT-100 reflects the ultrasound to provide strong back-scattering. MVT-100 microbubbles resonate with ultrasound to provide strong harmonic signals. MVT-100 microbubbles will cavitate with higher levels of ultrasound and cavitation may be stable or inertial depending upon acoustic parameters and other factors.

The study is a multi centre ascending dose comparison of Definity and MVT-100 for use in echocardiography and will be performed in a sample of healthy volunteers who are randomized to receive either Definity or MVT-100.

This trial will assess safety and evaluate the following imaging metrics:

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Diagnostic
盲法
Single (Outcomes Assessor)

盲法说明

The interpreter of echocardiograms in the trial is blinded to the drug which was administered, MVT-100 or Definity.

入排标准

年龄范围
19 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Adult subjects 19 years of age or older, male or female
  • Female subjects must no longer have child-bearing potential (>1-year post menopause or surgically sterilized), or must
  • have a negative urine pregnancy test, and
  • be using and continue to use for 30 days after the study a medically effective method of contraception
  • Adequate hematologic, renal and hepatic function, as defined by:
  • Absolute neutrophil count (ANC) ≥ 1.5 x 109/L
  • Platelet count ≥ 100 x 109/L
  • Hemoglobin ≥ 90 g/L
  • Plasma creatinine< 1.5 x ULN
  • Total bilirubin within normal limits (< 2.5 x ULN if Gilbert's syndrome)
  • Aspartate transaminase (AST) and Alanine transaminase (ALT) < 2.5 x ULN
  • Subject must be willing and able to understand the study and provide written Informed Consent to participate in the study

排除标准

  • Myocardial infarction within six months prior to enrollment
  • Unstable angina, NYHA Class II or greater congestive heart failure
  • EKG evidence of uncontrolled arrhythmia or history of clinically significant arrhythmia within the past six months
  • Clinically significant Chronic Obstructive Pulmonary Disease (COPD) or other pulmonary condition that is not controlled by medication or requires oxygen frequently or continuously
  • A history of pulmonary emboli
  • Known hypersensitivity to perflutren, DEFINITY® or other echo contrast agent
  • Inability to remain supine for 60 minutes
  • Oxygen saturation < 95% on room air
  • History of allergic reaction attributed to compounds of similar chemical composition to MVT-100 or DEFINITY® or soy or egg allergies (see Investigator's Brochure)
  • Subject has received any investigational drug within thirty (30) days prior to enrollment into the study
  • Inability to comply with study procedures
  • Subjects with any medical condition deemed by the investigator to make the subject inappropriate for participation

研究组 & 干预措施

Definity

Active Comparator

Each subject receives 100 uL x 2, 200 uL x 3, 300 uL x 2 or 1 vial of DEFINITY® 100 diluted in 50 mL of NS as follows: Two milliliter bolus over 10 seconds prior to each infusion rate;, then infusions will run for 5 minutes at 60 mL per hour, 5 minutes at 90 mL per hour, 5 minutes at 100 mL per hour and 5 minutes at 120 mL per hour.

干预措施: Echocardiogram (Diagnostic Test)

Definity

Active Comparator

Each subject receives 100 uL x 2, 200 uL x 3, 300 uL x 2 or 1 vial of DEFINITY® 100 diluted in 50 mL of NS as follows: Two milliliter bolus over 10 seconds prior to each infusion rate;, then infusions will run for 5 minutes at 60 mL per hour, 5 minutes at 90 mL per hour, 5 minutes at 100 mL per hour and 5 minutes at 120 mL per hour.

干预措施: Definity (Drug)

MVT-100

Experimental

Each subject receives 100 uL x 2, 200 uL x 3, 300 uL x 2 or 1 vial of MVT-100 diluted in 50 mL of NS as follows: Two milliliter bolus over 10 seconds prior to each infusion rate;, then infusions will run for 5 minutes at 60 mL per hour, 5 minutes at 90 mL per hour, 5 minutes at 100 mL per hour and 5 minutes at 120 mL per hour.

干预措施: Echocardiogram (Diagnostic Test)

MVT-100

Experimental

Each subject receives 100 uL x 2, 200 uL x 3, 300 uL x 2 or 1 vial of MVT-100 diluted in 50 mL of NS as follows: Two milliliter bolus over 10 seconds prior to each infusion rate;, then infusions will run for 5 minutes at 60 mL per hour, 5 minutes at 90 mL per hour, 5 minutes at 100 mL per hour and 5 minutes at 120 mL per hour.

干预措施: MVT-100 (Drug)

结局指标

主要结局

Oxygen Saturation

时间窗: Day of study

The null hypothesis for safety (H0) will be: MVT-100 is not as safe as DEFINITY®. The alternative hypothesis (HA) for safety will be: MVT-100 is equivalent to, or safer than, DEFINITY®. Specifically, the following hypotheses will be tested: HA: Δ2min QT interval EKG(MVT-100) ≤ Δ2min QT interval EKG(Definity®) HA: Δ2min Blood Pressure(MVT-100) ≤ Δ2min Blood Pressure(Definity®) HA: Δ2min Heart Rate(MVT-100) ≤ Δ2min Heart Rate(Definity®) HA: Δ2min O2(MVT-100) ≤ Δ2min O2(Definity®) HA: Other Symptom(2min post MVT-100) ≤ Other Symptom(2min post Definity®)

Other Symptoms

时间窗: Day of study

The null hypothesis for safety (H0) will be: MVT-100 is not as safe as DEFINITY®. The alternative hypothesis (HA) for safety will be: MVT-100 is equivalent to, or safer than, DEFINITY®. Specifically, the following hypotheses will be tested: HA: Δ2min QT interval EKG(MVT-100) ≤ Δ2min QT interval EKG(Definity®) HA: Δ2min Blood Pressure(MVT-100) ≤ Δ2min Blood Pressure(Definity®) HA: Δ2min Heart Rate(MVT-100) ≤ Δ2min Heart Rate(Definity®) HA: Δ2min O2(MVT-100) ≤ Δ2min O2(Definity®) HA: Other Symptom(2min post MVT-100) ≤ Other Symptom(2min post Definity®)

Blood Pressure

时间窗: Day of study

The null hypothesis for safety (H0) will be: MVT-100 is not as safe as DEFINITY®. The alternative hypothesis (HA) for safety will be: MVT-100 is equivalent to, or safer than, DEFINITY®. Specifically, the following hypotheses will be tested: HA: Δ2min QT interval EKG(MVT-100) ≤ Δ2min QT interval EKG(Definity®) HA: Δ2min Blood Pressure(MVT-100) ≤ Δ2min Blood Pressure(Definity®) HA: Δ2min Heart Rate(MVT-100) ≤ Δ2min Heart Rate(Definity®) HA: Δ2min O2(MVT-100) ≤ Δ2min O2(Definity®) HA: Other Symptom(2min post MVT-100) ≤ Other Symptom(2min post Definity®)

Heart Rate

时间窗: Day of study

The null hypothesis for safety (H0) will be: MVT-100 is not as safe as DEFINITY®. The alternative hypothesis (HA) for safety will be: MVT-100 is equivalent to, or safer than, DEFINITY®. Specifically, the following hypotheses will be tested: HA: Δ2min QT interval EKG(MVT-100) ≤ Δ2min QT interval EKG(Definity®) HA: Δ2min Blood Pressure(MVT-100) ≤ Δ2min Blood Pressure(Definity®) HA: Δ2min Heart Rate(MVT-100) ≤ Δ2min Heart Rate(Definity®) HA: Δ2min O2(MVT-100) ≤ Δ2min O2(Definity®) HA: Other Symptom(2min post MVT-100) ≤ Other Symptom(2min post Definity®)

QT Interval

时间窗: Day of study

The null hypothesis for safety (H0) will be: MVT-100 is not as safe as DEFINITY®. The alternative hypothesis (HA) for safety will be: MVT-100 is equivalent to, or safer than, DEFINITY®. Specifically, the following hypotheses will be tested: HA: Δ2min QT interval EKG(MVT-100) ≤ Δ2min QT interval EKG(Definity®) HA: Δ2min Blood Pressure(MVT-100) ≤ Δ2min Blood Pressure(Definity®) HA: Δ2min Heart Rate(MVT-100) ≤ Δ2min Heart Rate(Definity®) HA: Δ2min O2(MVT-100) ≤ Δ2min O2(Definity®) HA: Other Symptom(2min post MVT-100) ≤ Other Symptom(2min post Definity®)

次要结局

  • Cardiac Segment Visualization(Day of Study)
  • Left Ventricular Opacification (LVO)(Day of Study)