跳至主要内容
临床试验/NCT02277990
NCT02277990已完成4 期

Cardiac Implantable Electronic Device (CIED) Antibiotic Envelope Infection Prevention Trial

Medtronic Cardiac Rhythm and Heart Failure201 个研究点 分布在 1 个国家目标入组 7,075 人开始时间: 2015年1月1日最近更新:
适应症

试验速览

阶段
4 期
状态
已完成
发起方
入组人数
7,075
试验地点
201
主要终点
12 Month Kaplan-Meier Estimate of Major CIED Infection Rate

研究概览

简要总结

Medtronic , Inc. is sponsoring the World-wide Randomized Antibiotic Envelope Infection Prevention Trial (WRAP-IT), a randomized, prospective, multi-center, single blinded, post-market, interventional clinical study. This study will evaluate the ability of the TYRX™ envelope to reduce major Cardiac Implantable Electronic Device (CIED) infections through 12-months post-procedure following CIED generator replacement, upgrade, revision, or de novo cardiac resynchronization therapy defibrillator (CRT-D) implant. Additionally, this large device study provides the unique opportunity to prospectively characterize the performance of Medtronic's lead monitoring features in subjects whose CIED system includes a transvenous right ventricular (RV) defibrillation lead. Finally, the WRAP-IT study will serve as a post-approval study for those geographies requiring a post-approval study of the TYRX™ envelope.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Prevention
盲法
Single (Participant)

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patient is willing to sign and date the study patient informed consent (PIC) form
  • Patient is at least 18 years of age and meets age requirements per local law
  • Patient is planned to undergo at least one of the following:
  • a. Patient has existing cardiac implantable electronic device (CIED) and is undergoing implantable pulse generator (IPG) (including cardiac resynchronization therapy pacemaker [CRT-P]), implantable cardioverter-defibrillator (ICD) or cardiac resynchronization therapy defibrillator (CRT-D) replacement or upgrade with a new Medtronic generator
  • i. Subjects planned to have leads added, or extracted and added for upgrades can be enrolled OR
  • b. Patient will undergo a de novo Medtronic CRT-D system implant per approved indications
  • c. Patient has existing study eligible Medtronic CIED in which the pocket was not accessed within the last 365 days, and is undergoing pocket or lead revision
  • Willing to provide the contact information for the physician who provides followup for his/her CIED
  • Willing and able to comply with scheduled follow-up and study related activities

排除标准

  • Known allergy to minocycline or rifampin or their derivatives, or any other known contraindications to implantation of the TYRX envelope.
  • Current therapy with chronic oral immunosuppressive agents or ≥ 20mg/day of Prednisone or equivalent.
  • Hemodialysis or peritoneal dialysis.
  • Prior Cardiac transplantation or existing Ventricular Assist Device (VAD).
  • Require long-term vascular access for any reason.
  • Prior history of a CIED infection, other prosthetic device infection, or endovascular infection, including endocarditis, in the past 12 months.
  • Physical, clinical, or laboratory signs or symptoms consistent with an active infection (including but not limited to pneumonia, urinary tract, cellulitis, or bacteremia)
  • Systemic lupus erythematous, because minocycline has been reported to aggravate this condition
  • Female patient who is pregnant, or of childbearing potential and not on a reliable form of birth control. Women of childbearing potential are required to have a negative pregnancy test within 7 days prior to device procedure
  • Participation in another study that may confound the results of this study. Co-enrollment in concurrent trials is only allowed when documented pre-approval is obtained from the Medtronic study manager.

结局指标

主要结局

12 Month Kaplan-Meier Estimate of Major CIED Infection Rate

时间窗: Implant to 12 months

CIED infections are defined as (1) superficial cellulitis in the region of the CIED pocket with wound dehiscence, erosion, or purulent drainage, (2) deep incisional or organ/space (generator pocket) surgical site infection that meets the Centers for Disease Control and Prevention criteria, independent from time of surgery, (3) persistent bacteremia, or (4) endocarditis. Major CIED infections are defined as a CIED infection resulting in one or more of the following: * CIED system removal * Any invasive procedure (e.g. pocket opened) without system removal * Treatment with antibiotic therapy if the subject is not a candidate for system removal and infection recurrence after completion of antibiotic therapy or evidence of deep infection with wound dehiscence, erosion, or purulent drainage * Death

次要结局

  • Kaplan-Meier Estimate of a Major Infection Throughout Follow-up(Throughout study follow-up Kaplan-Meier Estimate is at 36 Months)
  • 12 Month Kaplan-Meier Estimate of Major or Minor CIED Infection(Implant to 12 months)
  • 12 Month Kaplan-Meier Estimate of a CIED Procedure Related or System Related Complication(Implant to 12 months)

研究者

发起方
Medtronic Cardiac Rhythm and Heart Failure
申办方类型
Industry
责任方
Sponsor

研究点 (201)

Loading locations...

相似试验