Attain StarFix® Model 4195 LV Lead Extraction Study
Medtronic Cardiac Rhythm and Heart Failure0 个研究点目标入组 227 人开始时间: 2009年7月最近更新:
适应症
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 227
- 主要终点
- Removal success of LV leads implanted for more than 180 days
研究概览
简要总结
The purpose of this study is to characterize the removability of the Attain StarFix® Model 4195 Left Ventricular (LV) Lead (StarFix®). The goal of the trial is to evaluate the lead removal success in patients that are indicated for left ventricular lead removal. This study is required by the Food and Drug Administration (FDA) as a condition of approval for the Attain StarFix® Model 4195 LV Lead.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Subjects with a Class I/II indication and/or physician discretion for left ventricular lead removal
- •Medtronic Model 4195 LV lead implanted for at least 181 days at time of extraction, or other Medtronic LV Lead (non-Model 4195) implanted for at least 181 days at time of extraction, or Medtronic Model 4195 LV lead implanted for 90-180 days
- •Intention to remove the LV lead prior to the extraction procedure
- •Subject is 18 years of age or older
- •Subject (or subject's legally authorized representative) has signed and dated the Patient Consent Form and is willing and able to comply with the protocol
排除标准
- 未提供
结局指标
主要结局
Removal success of LV leads implanted for more than 180 days
时间窗: More than 180 days post-implant
次要结局
- Removal success of Medtronic Model 4195 LV Leads implanted for 90-180 days(90 -180 days post-implant)
- Adverse Events that are related to the LV lead, the extraction procedure, or the extraction tool.(0 to 45 days post-lead extraction)
- Success of lead removal by how long the lead has been implanted(More than 180 days post-implant)
- Summary of tools & techniques used to remove LV leads.(More than 180 days post-implant)
研究者
相似试验
已完成
不适用
Model 4195 Left Ventricular (LV) Lead Chronic Performance StudyHeart FailureNCT00869921Medtronic1,322
已完成
不适用
Model 4196 Left Ventricular (LV) Lead Chronic Performance StudyHeart FailureNCT00930904Medtronic1,847
已完成
不适用
The effectiveness of implant-supported removable partial dentures in partially edentulous patients: A pilot studyJPRN-UMIN000025283Hokkaido University6
已完成
2 期
The effectiveness of implant-supported removable partial dentures in partially edentulous patients: A pilot studyPatients with mandibular unilateral free-end edentulismJPRN-jRCTs012180003Takayama Yoshiyuki6
已完成
不适用
Attain StarFix™ Model 4195 Left Ventricular LeadHeart FailureNCT00269230Medtronic Cardiac Rhythm and Heart Failure441