Demonstration Study of the Interest of the MEDTRUM A7+ TouchCare Insulin Patch Pump Versus INSULET Omnipod® Patch Pump

Medtrum France2 个研究点 分布在 1 个国家目标入组 93 人开始时间: 2020年1月29日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
93
试验地点
2
主要终点
Estimation of A1C (%) Based on Average Blood Glucose Measured by Continuous Glucose Sensor on the Last 10 Weeks

研究概览

简要总结

Demonstration study of the interest of the MEDTRUM A7+ TouchCare insulin patch pump versus INSULET Omnipod® patch pump

详细描述

Compare the daily use of two single usage patch pumps and demonstrate the interest of use of the A7+TouchCare® (Medtrum) patch pump for type 1 & 2 diabetes management.

Main objective is an estimation of Patients A1C (Glycated Haemoglobin) based on the average blood glucose (obtained from a Flash glucose monitoring) and to compare it in both groups.

Secondary objectives:

  • comparison of mean A1C (laboratory values) between the two groups at Baseline and study end. Comparison to be established in a non-inferiority
  • Observe Skin & overall Tolerance, Technical incidents with the device (failure, disconnection, catheter obstruction…)
  • Collection of Glucose metrics (minimum, maximum, average/median, standard deviation, out of range value, percentage of time in range, glucose variability)

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patient with type 1 or 2 diabetes, 18 years of age and over
  • Patients already equipped with Omnipod® ® (INSULET) insulin patch pump and Abbott FreeStyleLibre sensor®.
  • A1C ranking from : >= 6,5% to <= 9.5%
  • Any type of rapid insulin except FIASP (which can be substituted if necessary) with 60 IU max per day (unauthorized use of insulin supplements by pen injector)
  • Patient able to receive and understand study information, give written informed consent, and easily participate to the trial
  • Patient affiliated to the French social security system

排除标准

  • - Patient already participating in another study
  • Patient under the protection of justice or under guardianship or curatorship
  • Type 2 diabetic patient requiring a daily insulin dose > 60 IU
  • Patients not suitable for suing insulin pump such as: severe psychiatric disorders, rapidly progressing ischemic or proliferative retinopathy before laser treatment, and exposure to high magnetic fields
  • Patients allergic to nickel and adhesive
  • Pregnant women, breastfeeding women
  • Or any other criteria as appreciated by the study investigator.

结局指标

主要结局

Estimation of A1C (%) Based on Average Blood Glucose Measured by Continuous Glucose Sensor on the Last 10 Weeks

时间窗: Month 3

A1C will be estimated by a Continuous Glucose Measurement (FreeStyle Libre®) for all patients, at baseline and end of the study (12 weeks). The main objective is to demonstrate Non-inferiority efficacy (PP then ITT) of Medtrum A7+ insulin patch pump vs Insulet Omnipod® insulin patch pump (2 randomized groups). For the primary outcome, A1C will be estimated and appear in percentage based on assessment done by a Continuous Glucose Monitoring system. The A1C obtained in real life for the group using the comparator pump (Omnipod®) is estimated at 7.8%. Assuming that blood glucose level will be the same with Medtrum pump and based on a defined non-inferiority margin ∆ = + 0.4 (following FDA Guidance for Industry Diabetes Mellitus: Developing Drugs and Therapeutic Biologics for Treatment and Prevention).

次要结局

  • Report Patients' Laboratory Hemoglobin A1C Difference Between Baseline and 3 Months(Month 3)
  • Compare The Time Spent in Range(Month 3)
  • Compare Patients Pump Satisfaction(Month 3)
  • Compare Patients PDM Satisfaction(Month 3)
  • Number of Participants With at Least One Pump Occlusion(Month 3)

研究者

发起方
Medtrum France
申办方类型
Industry
责任方
Sponsor