跳至主要内容
临床试验/NCT04458883
NCT04458883招募中不适用

The Next Leap in Cardiac Magnetic Resonance Imaging:Cycling the Field The TITAN Study

University of Aberdeen4 个研究点 分布在 1 个国家目标入组 150 人开始时间: 2020年8月1日最近更新:
适应症

试验速览

阶段
不适用
状态
招募中
入组人数
150
试验地点
4
主要终点
Cardiac Magnetic Resonance Imaging

研究概览

简要总结

The main aim of the study is to build and test a cardiac-specific coil purposely assembled in house to suit the FFC-MRI whole-body prototype and to test if it could be used for clinical cardiac scans in human subject populations.

详细描述

Aberdeen scientists are at the forefront of a new type of magnetic resonance imaging (MRI), having built in-house the only two available prototypes of Fast Field-Cycling MRI in the world - and these already have clinical imaging capabilities. Fast Field-Cycling MRI switches rapidly over a range of field strengths (0.2 T to 200 µT), providing a T1 dispersion curve. This information is invisible to fixed-field scanners and uncovers unique knowledge about motion and interaction between component molecules within a tissue (i.e. water/fat/proteins). In this application the investigators wish to use their in-house expertise further to extend the capability of our Fast Field-Cycling MRI to perform cardiac imaging by building the first-ever cardiac Fast Field-Cycling MRI coil and develop cardiac pulse sequences with ECG gating. The investigators will aim to establish the normalcy of T1 dispersion curves for left ventricular myocardium in healthy volunteers, and further on to distinguish the characteristics of post-myocardial infarction scar T1 dispersion curves.

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Parallel
主要目的
Basic Science
盲法
None

入排标准

年龄范围
20 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Participant who is willing and able to give informed consent for participation in the study
  • Healthy volunteers willing to give informed consent for participation in the study
  • Patients diagnosed with a previous myocardial infarction

排除标准

  • Unwillingness to participate
  • Claustrophobia
  • Contraindication to MRI scanning such as implantable cardiac devices
  • Participants who have had a previous myocardial infarction in the past of which they may not be aware and this is discovered whilst being scanned on the 3T MRI scanner, or who may have any other cardiology condition that they were previously unaware will not be included in the healthy control group, even if they present themselves to us as "healthy" at the time of the study visit
  • Pregnancy
  • Body habitus that may preclude comfortable positioning of the volunteer in either of the MRI scanners (>50cm in diameter)
  • Participants with abnormal kidney function that will preclude them from receiving a contrast agent

结局指标

主要结局

Cardiac Magnetic Resonance Imaging

时间窗: At baseline

Cardiac Magnetic Resonance Imaging - Cardiac Scan to assess cardiac function and T1 dispersion curves

Fast Field Cycling Magnetic Resonance Imaging

时间窗: At baseline

Fast Field Cycling Magnetic Resonance Imaging - Cardiac Scan to assess cardiac function and T1 dispersion curves

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Sponsor

研究点 (4)

Loading locations...

相似试验