跳至主要内容
临床试验/NCT02273037
NCT02273037已完成不适用

The Fetal Heart Monitor Project - Human Energy to Save Lives: Intermittent Auscultation Using Handheld Doppler: a Randomized Controlled Trial Comparing Perinatal Outcomes in Uganda

The Hospital for Sick Children3 个研究点 分布在 2 个国家目标入组 1,987 人开始时间: 2012年1月最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
1,987
试验地点
3
主要终点
Quality of Partograms

研究概览

简要总结

A novel handheld Doppler has been developed which is rugged and is powered only by a hand crank. This study aims to test the use of this Doppler versus the Pinard horn to monitor the fetal heart rate in labour in a hospital setting in Uganda. The investigators propose that with its ease of use, both for the woman and midwife, midwives using the Doppler will identify more babies in need of prompt delivery and the risk of stillbirth and neonatal mortality will decline. In the research study, the investigators will compare the risk of stillbirths and neonatal mortality in two randomized groups of labouring women.

The second part of the study consists of an audit of the documentation in labour by midwives. The partograph is an uncomplicated, low cost form on which observations during labour are documented. It includes three sections of information: fetal condition, maternal condition and labour progress. Although the use of a partograph during labour is strongly recommended by the WHO, there are limited published systematic evaluations of the correct use of the tool. The investigators aim to use this randomized trial design to assess rates of intrapartum stillbirth and neonatal mortality in the first 24 hours after delivery, and assess the quality of partographs comparing two groups.

This trial will provide insights on the potential benefits of using handheld Doppler devices for intrapartum monitoring, and the audit of partograph quality will provide insights to improve care during labour. This study hypothesizes that the quality of partograph completion and of fetal heart rate monitoring may systematically differ between the Doppler and Pinard groups.

详细描述

  1. Objectives:

  2. To evaluate the intervention of a wind-up, handheld Doppler fetal heart rate monitor (Doppler) and to identify implementation challenges;

  3. To identify process issues and the impact of the Doppler on rates of intrapartum stillbirth and neonatal deaths within 24 hours, in comparison to use of the Pinard horn (current practice);

  4. To assess the quality of partographs using a standardized scoring system to audit overall completion and quality, and fetal heart rate monitoring specifically; we will compare the audit results between partographs where monitoring was done with the Pinard horn versus the Doppler. The hypothesis being that the quality of partograph completion and of fetal heart rate monitoring may systematically differ between these two groups;

  5. To build the research capacity of Ugandan midwives by facilitating their participation in this research study.

  6. Study design

Equal randomization clinical trial to compare Pinard horn (current practice) versus Doppler (intervention) to monitor the fetal heart in labour. 3. Characteristics of the study population

  1. Number of participants Based on the results of a randomized controlled trial in urban Zimbabwe in 1994 [Mahomed, BMJ], the investigators hypothesize that use of a handheld Doppler fetal heart monitor will reduce the rate of intrapartum stillbirth by at least 30% compared to monitoring fetal heart rate with a Pinard horn. With 80% power to detect at least a 30% reduction in stillbirths with 95% confidence, 840 labouring women would need to be enrolled in each of the two comparison groups. Adding 20% to allow for losses to follow-up and statistical adjustments/stratification, 1008 labouring women are required for each comparison group.
  2. Location of the research The study will be conducted in the San Raphael of St Francis Hospital Nsambya Hospital, in Uganda. This is a general hospital and maternity located in the peri-urban region of Kampala City. It is a private not-for-profit institution with 7,500 annual deliveries. In addition, it offers training for residents, intern doctors, nurses, midwives and technicians.
  3. Data analysis The investigators will review the partograph and record their findings on a tool developed for this purpose. The data that will be recorded will be of statistical nature but at the bottom of each Partograph Assessment Tool is space for qualitative comments from the reviewer. Besides date of birth and the patient file identity number no data will be recorded which can reveal the identity of the patient. This is to ensure patient privacy and confidentiality of the data, without losing the possibility to retrieve the file from medical records if needed. After recording the data on a hard copy in the hospital, the data will be entered twice into the statistical package before analysis. The information that this will give will be descriptively analysed. The proportion and incidence risk rate of participants who experience each fetal outcome under study and the mean partograph scores will be compared between the intervention and control groups.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Diagnostic
盲法
None

入排标准

性别
Female
接受健康志愿者

入选标准

  • All mothers presenting to the labour wards in labour with a singleton pregnancy above 37 completed weeks of gestation, and cephalic presentation
  • All mothers admitted to the labour ward for monitoring of active phase of labour with a live intrauterine fetus

排除标准

  • Mothers admitted to the labour wards with a pregnancy gestation age below 37 weeks
  • Mothers admitted with a diagnosis of intra uterine fetal death
  • Mothers presenting in second stage of labour
  • Mothers with a high risk pregnancy eg pre eclampsia, ante partum hemorrhage
  • Mothers being admitted for an elective caesarean section

研究组 & 干预措施

Pinard horn

Placebo Comparator

Pinard horn (current practice) used to monitor the fetal heart rate in labour in this arm of the study.

干预措施: Partograph (Procedure)

Fetal heart rate Doppler

Experimental

Doppler used to monitor the fetal heart rate in labour in this arm of the study.

干预措施: Fetal heart rate Doppler (Device)

Fetal heart rate Doppler

Experimental

Doppler used to monitor the fetal heart rate in labour in this arm of the study.

干预措施: Partograph (Procedure)

结局指标

主要结局

Quality of Partograms

时间窗: in labour

To assess the quality of partographs using a standardized scoring system to audit overall completion and quality, and fetal heart rate monitoring specifically. The investigators will compare the audit results between partographs in the Pinard and Doppler group.

Stillbirth and Neonatal Death

时间窗: 0-24hour of delivery

Compare the incidence of fresh stillbirth and neonatal death (within 24h of age) in the Pinard group (current practice) and the Doppler group (study intervention).

次要结局

  • Identification of Abnormal Fetal Heart Rate(In labour)
  • Cesarean Delivery (Includes Cesarean Delivery/Intra-uterine Resuscitation/Assisted Delivery)(Birth)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Diego Bassani

Epidemiologist

The Hospital for Sick Children

研究点 (3)

Loading locations...