跳至主要内容
临床试验/NCT04437914
NCT04437914招募中不适用

Accuracy of Cardiac Arrhythmias and Conduction Disorders Diagnosis Using Smartwatch in Comparison to Conventional Electrocardiogram in Patients With Cardiovascular Disease

Federal University of Piaui1 个研究点 分布在 1 个国家目标入组 110 人开始时间: 2021年6月7日最近更新:
适应症

试验速览

阶段
不适用
状态
招募中
发起方
入组人数
110
试验地点
1
主要终点
Positive diagnostic correlation

研究概览

简要总结

Implantable devices increase the detection of silent atrial fibrillation in high-risk populations, being a useful tool in the early diagnosis of these patients, allowing monitoring for a longer time. Currently, these devices can be used for monitoring and possible early diagnosis of abnormalities in order to prevent health complications and bring about better outcomes, as well as monitor the user's progress and thus prevent more serious developments. Objective: to analyze, in patients with cardiovascular disease, the electrocardiographic aspects detected from the device in comparison to the conventional electrocardiogram, identifying aspects of similarity between the tracings obtained and automatic diagnostic accuracy by the device and by the visual assessment of the tracing. Method: a cross-sectional observational study of diagnostic accuracy will be carried out at the University Hospital of the Federal University of Piaui. The following parameters were considered: significance level of 95%, test power of 80%, value of the disease diagnosis rate of 84%, area under the receiver operating characteristic curve of 94% and an equal proportion of the number of positive and negative cases. The minimum sample size consisted of 100 patients, and an additional 10% will be added to compensate for possible losses. A total of 110 patients will be invited to participate in the study. Patients aged ≥ 18 years will be included, with the presence of one or more diagnoses below: systemic arterial hypertension, heart failure, valvular disease, coronary atherosclerotic disease, myocardial infarction, endocarditis, myocarditis, diabetes, cardiac arrhythmias and patients with cardiac pace or implantable automatic defibrillator. The variables analyzed will be: clinical-demographic data of the patients, including age, sex, race, socioeconomic profile; comorbidities and electrocardiographic findings as measured by the clock and conventional ECG. The data will be analyzed comparatively between the groups: 1 = EKG on the clock; 2 = 12-lead conventional EKG and DI (single lead). The primary outcome will be the positive diagnostic correlation of the data obtained in group 1 in relation to group 2. Secondary outcomes: successful measurement of the electrocardiographic record by the clock; diagnostic accuracy of atrial fibrillation and other heart rhythm disorders.

详细描述

The main objective of this study is to analyze, in patients with cardiovascular disease, the electrocardiographic aspects detected from the smartwatch device in comparison to the conventional electrocardiogram, identifying aspects of similarity between the tracings obtained and automatic diagnostic accuracy by the device and by visual assessment. of the layout. The secondary objectives will be to evaluate in the same population: aspects of practicality for the use of smart watches in clinical practice in cardiology; the success rate in obtaining the electrocardiographic tracing with adequate quality by the smart watch and describe the types of failure and assess the clinical characteristics related to the failure in obtaining the electrocardiographic tracing by the smart watch. Method: An observational, transversal, study of diagnostic accuracy will be carried out at the University Hospital of the Federal University of Piaui.

The sample size was calculated using MedCalc Statistical Software version 19.2.3 (MedCalc Software Ltd, Ostend, Belgium). For the sample calculation, the following parameters were considered: significance level of 95%, test power of 80%, value of the disease diagnosis rate of 84%, area under the receiver operating characteristic curve of 94% and equal proportion of number of positive and negative cases. The minimum sample size consisted of 100 patients, and an additional 10% will be added to compensate for possible losses. A total of 110 patients will be invited to participate in the study. Inclusion criteria: • Age ≥ 18 years;

• Patients followed up in the cardiology sector, hospitalized or outpatient, with the presence of one or more of the following diagnoses: systemic arterial hypertension, heart failure, valve disease, coronary atherosclerotic disease, myocardial infarction, endocarditis, myocarditis, diabetes, cardiac arrhythmias and patients with cardiac pacemakers or implantable automatic defibrillators. Exclusion criteria: • Patients who have electrocardiographic tracings, whether obtained from the watch or the conventional method, of poor quality that make it impossible or that makes the diagnosis difficult due to the technical aspect of the performance. • Withdrawal of the consent form at the request of the patient or guardian. Primary outcome: • Positive diagnostic correlation of the data obtained in group 1 (clock) in relation to group 2 (conventional ECG 12 leads and DI - single lead). Secondary outcome: • Successful verification of the electrocardiographic record by the watch; • Diagnostic accuracy of atrial fibrillation; • Diagnostic accuracy of heart rhythm disorders, excluding atrial fibrillation. Ethical aspects: All patients will be informed about the principles and objectives of the protocol before inclusion in the study and will be given explanations of potential advantages or disadvantages. All procedures involved in this study will be in accordance with the Helsinki Declaration of 1975, updated in 2013. The study will follow the principles of good clinical practice and the terms of Resolution No. 466/12 of December 12, 2012 of the National Health Council Ministry of Health. All patients or legal guardians will sign the informed consent form in writing before selection. Patients will be guaranteed that early withdrawal from the study will always be possible, without any consequence or impairment in their subsequent medical care. Data will be collected only after approval by the ethics and research committee. Those who do not sign the Informed Consent will not be included. Data collect The variables analyzed will be: clinical-demographic data of the patients, including age, sex, race, socioeconomic profile; comorbidities and electrocardiographic findings as measured by the clock and conventional ECG. The data will be analyzed comparatively between the groups: 1 = ECG on the clock; 2 = 12-lead conventional ECG and DI (single lead).

Electrocardiographic recording devices The smart watch used will be the Apple Watch series 4, from Apple Inc. (Specifications: Sensor I, 511 Hz, mobile operating system 13.1.3, operating system 6.0.1, Watch 4.2). For the recording of the conventional electrocardiogram, a mobile device will be used that allows the recording of 12 simultaneous leads and the rhythm tracing of the DI lead.

Criteria for electrocardiographic diagnosis The criteria for electrocardiographic diagnosis of morphological aspects, intervals and conclusive report will be based on the guideline of the Brazilian Society of Cardiology on the analysis and issuance of electrocardiographic reports.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Cross Sectional

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Age ≥ 18 years;
  • Presence of one or more of the following diagnoses: systemic arterial hypertension, heart failure, valve disease, coronary atherosclerotic disease, myocardial infarction, endocarditis, myocarditis, diabetes, cardiac arrhythmias and patients with cardiac pacemakers or implantable automatic defibrillators.

排除标准

  • Patients who have electrocardiographic tracings, whether obtained from the watch or the conventional method, of poor quality that make it impossible or that makes the diagnosis difficult due to the technical aspect of the performance.
  • Withdrawal of the consent form at the request of the patient or guardian.

结局指标

主要结局

Positive diagnostic correlation

时间窗: 30 days

Positive diagnostic correlation of the data obtained in group 1 (clock) in relation to group 2 (conventional ECG 12 leads and DI - single lead).

次要结局

  • Diagnostic accuracy 1(30 days)
  • Diagnostic accuracy 2(30 days)

研究者

发起方
Federal University of Piaui
申办方类型
Other
责任方
Principal Investigator
主要研究者

Carlos Eduardo Batista de Lima, MD, PhD

Professor of Medicine (Cardiology)

Federal University of Piaui

研究点 (1)

Loading locations...

相似试验