跳至主要内容
临床试验/NCT04268680
NCT04268680已完成不适用

Perioperative Case Series: Qualitative Evaluation of Gait Cycle and Ground in Knee

I.R.C.C.S Ospedale Galeazzi-Sant'Ambrogio1 个研究点 分布在 1 个国家目标入组 6 人开始时间: 2017年11月7日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
6
试验地点
1
主要终点
Perioperative Case Series: clinical evaluation of gait cycle and ground in Knee arthroplasty patients

研究概览

简要总结

Gait analysis is a quick and powerful tool with a wide range of clinical applications in various fields. However, due to the expensive and highly specialized equipment required, gait studies are mostly limited to academic research centers and small sample sizes and no large-scale, randomized controlled trials have been performed. Several authors have proposed inexpensive accelerometer-based systems to remedy this situation. Through mathematic transformation they adequately measure step time and length. With these systems however only temporal spatial gait parameters can be recorded; kinetic gait parameters, such as ground reaction force, cannot be measured. As these kinetic parameters are important for clinical studies, especially in fracture and rehabilitation research different methods are needed. Its availability is mainly limited to research centers, conventional gait analysis is further hindered by its stationarity and that it only allows momentary views of the patient's gait in a confined research environment. Even smaller, wearable systems have to be attached to an external apparatus, or are limited by their battery capacity, data storage and other device specific factors. Furthermore, the use of these systems is at an early clinical stage and their full potential not yet developed. As most disease processes are continuous, tools with long-term, continuous measuring capabilities are needed. For this reason a new pressure-measuring insole with built in battery and data storage was developed in cooperation with the AO Foundation(AO Foundation, Davos, Switzerland). The system offers complete independence from any external measures for up to 4 weeks and monitors a patient step during this time.

The purpose of this pilot study is to investigate which how TKA arthroplasty may impact gait during early and medium term rehabilitation phase. This will be done through the use of the OpenGo Sensor Insole (Moticon GmbH).

详细描述

Advanced degenerative arthropathies of the knee ultimately manifest as pain and a loss of function leading to impaired gait and activity. Total knee arthroplasty (TKA) is a procedure that aim to eliminate pain, restore the function of the joint and ultimately improve the ability of the patient to move and live an active life. TotalKneeArthroplasty has a history of success, but as the orthopedic and healthcare sectors evolve, a greater level of scrutiny and expectation for success will be applied to surgeons and device makers alike. In response to these elevated levels of scrutiny and expectation more advanced methods will likely be required to better capture and understand how a TotalKneeArthroplasty impacts patient function both on an individual, patient by patient, basis as well as on device design and surgical technique basis.

The present study is aimed at performing a preliminary evaluation to provide:

More advanced insight into a patient's functional recovery and rehabilitation with the potential for phisician's to intervene earlier and with greater specificity to any challenges encountered by the patient Objective evidence of the quality and value of the intervention on an individualized basis. Study objectives Any change in gait as a result of arthroplasty and dynamics of gait recovery during acute recovery and rehabilitation timeframe. Outcome measures will be gait cycle and ground: foot interaction dynamics which will be observed longitudinally and compared to the healthy contralateral limb (ground: foot interaction dynamics) as well literature data (gait cycle).

Primary objective:Evaluation of gait cycle and ground in primary TotalKneeArthroplasty patients compared to the healthy contralateral limb.

Secondary objectives:Easy of use. Qualitative user (Phisician and patient) feedback on experience using and wearing the insoles Study design:This is, single arm, prospective, single center, pilot study to measure the pre-operative and post-operative gait and ground: foot interaction dynamics of 6 subjects who are undergoing TotalKneeArthroplasty .

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
45 Years 至 75 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • primary TKA
  • 45-75 years of age (included)
  • skeletally mature
  • willing and able to participate in required pre-op and follow-up visits at the investigational site and to complete study procedures and questionnaires
  • consented to participating in the study by signing the IRB/EC approved informed consent form

排除标准

  • symptomatic/debilitating co-commitant arthropathy of non-operative joints (e.g. a TKA patient cannot have advanced arthritis of the contralateral knee or ipsilateral hip/ankle) that would impede or otherwise confuse the peri-operative measurement of gait.
  • Significant comorbidities that would impede the patients ability to participate in standard recovery and rehabilitation

结局指标

主要结局

Perioperative Case Series: clinical evaluation of gait cycle and ground in Knee arthroplasty patients

时间窗: baseline to 3 month

Evaluation of gait cycle and ground in primary TKA patients compared to the healthy contralateral limb.

次要结局

  • Perioperative Case Series: qualitative evaluation of gait cycle and ground in Knee arthroplasty patients(baseline to 3 month)

研究者

发起方
I.R.C.C.S Ospedale Galeazzi-Sant'Ambrogio
申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验

Perioperative Case Series: Qualitative Evaluation of... | 临床试验