An Ex-Vivo Human Model Study for Proof of Concept, Usability, Reproducibility, Radio-Opacity and Marker Retention
试验速览
- 阶段
- 不适用
- 状态
- 招募中
- 发起方
- 入组人数
- 100
- 试验地点
- 1
- 主要终点
- Gain experience with deployability of the device in multiple organs, through different needles and different routes of insertion (trans-cutaneous, endoscopic).
研究概览
简要总结
Currently available fiducial marker and fiducial insertion strategies are rudimentary, imprecise, not compatible with multiple insertion catheters/needles and are overall unreliable. STING-MARK device is the first universal, fully detachable and non-premounted radiopaque fiducial device system. Allowing biopsy prior to insertion, STING-MARK is easily and reliably delivered through-the-needle to the tumor, in order to accurately pinpoint its location for image-guided therapies. This study aims at establishing proof of concept for STING-MARK, by demonstrating its usability, reproducibility, radio-opacity and retention in a variety of clinically-relevant ex vivo organ samples.
详细描述
Patients undergoing surgical resection of solid organs at the CHUM or recipients of solid organ transplantation will be approached for consent into the study protocol. Human solid organs that are being removed for either elective surgery or transplantation will be removed in the standard manner and sent to the pathology laboratory as in the typical situation following removal. After the pathology team finishes with the organ, excess organ will be given to the research team for experimentation. In cases of recipient organs being removed for transplantation, they will be preserved in a plastic bag and then placed in the refrigerator. All experimentation will take place in the CRCHUM TID lab or Room 13 of the CHUM operating room.
Device insertion will occur with the designated needles and through the appropriate organ-specific route and imaging guidance. Multiple STING-MARK fiducials will be inserted. Plain film x-rays in 3 planes of the organs with the marker inserted will be taken and recorded.
Following experimentation, the organs will be appropriately labelled and returned to the pathology laboratory at the CHUM.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Device Feasibility
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Patients undergoing surgical resection of solid organs
- •Recipients of solid organ transplantation
排除标准
- 未提供
研究组 & 干预措施
StingMark Fiducial Marker
Device insertion will occur with the designated needles and through the appropriate organ-specific route and imaging guidance. Multiple STING-MARK fiducials will be inserted. Plain film x-rays in 3 planes of the organs with the marker inserted will be taken and recorded.
干预措施: Sting Mark Fiducial Marker (Device)
结局指标
主要结局
Gain experience with deployability of the device in multiple organs, through different needles and different routes of insertion (trans-cutaneous, endoscopic).
时间窗: Through study completion, an average of 1 year
1\) The deployability of the device will be measured with a deployability performance score (3=best over all metrics, 9=worst over all metrics) and compared with that of competing devices (Ultra EchoTip, Lumicoil) tested in parallel by the same user(s). No health outcomes are used in this score. Metrics used to establish this score are : operational efficiency ratio (the number of occurences of proper travel/anchoring/detaching over the total number of trials), time of operation and number of steps (from the first handling of the device to its detachment or lack thereof). Tests will be conducted on different organ locations (lung, oseophagus) with different routes of insertion (trans-cutaneous, endoscopic) using different models of 22Ga biopsy needles.
Verify stability of the device once inserted.
时间窗: Through study completion, an average of 1 year
2\) The stability of the device after insertion will be measured with a stability performance score (3=best over all metrics, 9=worst over all metrics) and compared with that of competing devices (Ultra EchoTip, Lumicoil) tested in parallel by the same user(s). No health outcomes are used in this score. Metrics used to establish this score are mean three-dimensional fiducial displacement and maximal unidirectional displacement (along with its axis). These metrics are calculated by constructing a displacement vector map based on X-ray images of marker position relative to each other and to key neighbouring biological structures (tumor, bones, organs, other markers) taken each day over a period of 3 days.
verify radio-opacity of the device following insertion.
时间窗: Through study completion, an average of 1 year
3\) The radio-opacity of the device after insertion will be measured with a stability performance score (4=best over all metrics, 12=worst over all metrics) and compared with that of competing devices (Ultra EchoTip, Lumicoil) tested in parallel by the same user(s). No health outcomes are used in this score. Metrics used to establish this score are : visual identification by surgeons and radiologists (based on their expertise by a simple yes/no criterion), automated radiotherapy machine software detection (based on the built-in detection criterion), mean pixel intensity and signal-to-noise ratio (from computer-based image analysis). These metrics are measured on MRI/X-ray/CT-scan images taken right after insertion and 1 day after insertion.
次要结局
- User feedback regarding usability of the device(Through study completion, an average of 1 year)