跳至主要内容
临床试验/NCT05752968
NCT05752968已完成不适用

Elevated Levels of Antibodies to Endotoxin Core in Hemodialysis Patients With Peripheral Artery Disease

Tungs' Taichung Metroharbour Hospital1 个研究点 分布在 1 个国家目标入组 155 人开始时间: 2023年5月3日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
155
试验地点
1
主要终点
Analysis of biomarkers of endotoxin core antibody (EndoCab) levels

研究概览

简要总结

Background

Peripheral arterial disease (PAD) and its relevant complications are more common in hemodialysis (HD) patients. The potential association regarding chronic kidney disease dysbiosis, inflammation and metabolic endotoxinemia in HD patients is unknown. A cross-sectional study will be carried out the evaluate the possible association endotoxin core antibody with asymptomatic PAD in a cohort of HD patients.

Methods

This cohort study enrolled 500 HD patients treated at a single center in Taichung city. Fasting blood samples will be collected to determine biochemical data Endotoxin core antibody levels and other related biomarkers. By the automatic oscillometric method, the ankle-brachial index (ABI) was measured. Low ABI was defined as any value < 0.9.

详细描述

Study Design and Patients This is a cross-sectional study involving hemodialysis patients from the hemodialysis unit of Tungs' Taichung MetroHarbor Hospital, Taiwan. A total of 500 patients over 20 years of age who receive hemodialysis with ultrapure dialysate three times weekly for at least 1 month are eligible for enrollment. We will exclude patients dialyzed with a catheter; who had an acute infection requiring hospitalization; and who had underlying malignancy or autoimmune diseases. In addition, patients who refuse to participate will be excluded. Information on participant demographics and comorbidities will be obtained from interviews and medical record reviews at the time of enrollment. Diabetes mellitus is defined by self-reported history or use of antidiabetic medications. Hypertension was defined as systolic blood pressure ≥140 mmHg, diastolic ≥90 mmHg, or use of antihypertensive agents. Pre-exisiting CVD is defined as coronary artery disease, as documented by coronary angiography or a history of myocardial infarction, class III or IV congestive heart failure, or stroke. This study will comply with the Declaration of Helsinki and will apply for approval from the Institutional Review Board of Tungs' Taichung MetroHarbor Hospital. All participants will give their written informed consent.

Laboratory Measurements Predialysis blood samples are obtained on a mid-week day. Within 30 min after sampling, the remaining blood will be centrifuged at 3,000 g for 10 min, immediately aliquoted and frozen at-70 °C until further analysis. The total serum cholesterol is measured through the reaction of cholesterol esterase/cholesterol oxidase/ peroxidase, using Hitachi 747 (Hitachi, Bohemia, NY, USA). HDL cholesterol is quantified after precipitation with polyethylene glycol at room temperature. Serum glucose concentrations are measured by the glucose oxidase method. Low-density lipoprotein cholesterol is calculated using the Friedewald formula. Total serum triglycerides are measured through the reaction of glycerol/ phosphate/oxidase and peroxidase. The serum levels of high-sensitivity C-reactive protein (hsCRP) are measured using a Behring Nephelometer II (Dade Behring, Tokyo, Japan). Serum levels of IL-6 and sCD14 are measured by a commercially available enzyme-linked immunosorbent assay (Quantikine HS Immunoassay kit, R&D System, Minneapolis, MN, USA). The LBP will be determined from serum samples and controls using standardized enzyme-linked immunosorbent assay methods (HK315-02, HyCult Biotech Inc., Uden, The Netherlands), and serum from 20 normal control subjects are used for interassay variation. Serum endotoxin core antibody will be tested using a commercially available EndoCab IgG ELISA assay (Hycult Biotech Inc., The Netherlands). In addition, serum LCN-2 (Lipocalin-2) and YKL-40 concentrations will be determined using enzyme linked immunosorbent assays

Endotoxin Measurement Endotoxin levels are measured using a Charles River Laboratories (CRL) Kinetic Chromogenic assay, Endochrome-K. A more detailed description of the methodology used has been described elsewhere [37]. Samples are thawed and diluted to 1 : 20 with a bio-dispersing agent (CRL, BD100) and heat to 75°C for 15 minutes. A standard curve (0.005 EU/mL and 5 EU/mL) is prepared using control standard endotoxin supplied by CRL. If endotoxin is detected, the samples are then reconstituted with an endotoxin-specific buffer (Charles River Endosafe BG-120) to avoid any β-glucan-related false positive reaction. A positive product control is included for each sample to eliminate the possibility of enhancement or inhibition of endotoxin measurement. The absorbance at 405 nm is measured at 30 second intervals for a total of 3600 seconds using a Biotek ELx808 plate reader. The assay reactions are held at 37°C throughout the assay period. Charles River Endosafe, EndoScan V software is used to generate a standard curve and analyze data using an onset time of 0.1 absorbance unit.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Cross Sectional

入排标准

年龄范围
20 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • A cohort of aged 20 or over, who receive hemodialysis with ultrapure dialysate three times weekly for at least 1 month.

排除标准

  • We will exclude patients dialyzed with a catheter; who had an acute infection requiring hospitalization; and who had underlying malignancy or autoimmune diseases. In addition, patients who refuse to participate will be excluded.

结局指标

主要结局

Analysis of biomarkers of endotoxin core antibody (EndoCab) levels

时间窗: 1 years

Plasma level of endotoxin core antibody (EndoCab) is a biomarkers for the risk of developing and presence of PAD

次要结局

  • Ankle Brachial Index Measurements(1 years)
  • Analysis of biomarkers of sCD14(1 years)
  • Analysis of biomarkers of LCN-2 (Lipocalin-2)(1 years)
  • Analysis of biomarkers of YKL-40(1 years)
  • Analysis of biomarkers of IL-6(1 years)

研究者

发起方
Tungs' Taichung Metroharbour Hospital
申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验