Pilot Study to Define Parameters of Elastography Compared to Color Flow Doppler Ultrasound in Renal Transplants

The University of Texas Health Science Center, Houston2 个研究点 分布在 1 个国家目标入组 10 人开始时间: 2006年6月1日最近更新:
适应症

试验速览

阶段
1 期
状态
终止
入组人数
10
试验地点
2
主要终点
Identification of features of a set of elastography images that can be characterized as those of a normally functioning transplanted kidney, or those of specific abnormalities

研究概览

简要总结

The study was developed to acquire images of normal, then abnormal, then unknown diagnosis for transplanted kidneys in order to determine whether the elastography imaging modality, a type of ultrasound imaging, can provide data useful for diagnosis of renal transplant abnormalities.

The specific aims of this study are:

  1. To define normal elastography imaging by correlation with clinical findings.
  2. To define specific abnormal elastography images by correlation with clinical findings.
  3. To determine whether elastography could be useful in early diagnosis of abnormalities of renal transplants, especially in early rejection.

详细描述

The study is collecting standard ultrasound and elastographic images of transplanted kidneys in order to perfect the imaging technique to get the best pictures, and to evaluate these images for characteristics that may be of diagnostic value.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Adult (over 18) male or female renal transplant patient
  • normally functioning
  • or being evaluated for a possible problem

排除标准

  • unwilling or unable to give informed consent

结局指标

主要结局

Identification of features of a set of elastography images that can be characterized as those of a normally functioning transplanted kidney, or those of specific abnormalities

时间窗: after up to 50 "normal" images are collected

次要结局

  • Assessment of the value of renal transplant imaging by elastography compared to standard ultrasound(by the time up to 100 images are obtained)