Calypso-based Deep Inspiration Breath Hold (DIBH) Radiation Treatments of Lung Cancer
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 48
- 试验地点
- 8
- 主要终点
- Feasibility of Calypso Transponders
研究概览
简要总结
The purpose of this study is to test the use of Calypso beacon implants as a way to determine where the lung tumor is located during radiation treatment. The Calypso beacons are small devices that are implanted in the lungs, near the tumor. They are able to send a signal to a tracking system to show where they are, and where the tumor is, as the patient holds their breath for the radiation treatment. The investigators want to find out what effects, good and/or bad, that this has on the patient and the way they treat the cancer in your lungs.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Treatment
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Patients must have histologic proof of malignancy suitable for thoracic radiation therapy
- •Patients planning to undergo radiation therapy for primary or recurrent malignancy of the lung or metastatic malignancy to the lung.
- •Age ≥ 18 years old
- •KPS ≥ 60%
- •Ability to hold their breath for >20 seconds for 5 times
- •Patients who are able to tolerate flexible bronchoscopy
- •Patients with life expectancy of at least 12 months
- •Patients able to have bronchoscopic placement of Calypso as confirmed on a recent (within the past 8 weeks) CT scan.
- •Patients who are able to comply with the protocol follow-up schedule.
排除标准
- •Patients unable to comply with instructions for DIBH
- •Patients with implants in the chest region that contain metal or conductive materials (e.g., metal implants, rods, or plates) which Calypso Medical considers will interfere with the Calypso System's electromagnetic localization.
- •Patients with active implanted devices, such as pacemakers, defibrillators, and drug infusion pumps since the effects of the Calypso System operation on these devices are unknown.
- •Patients with clinically significant active infections.
- •Patients with bronchiectasis in the region of the intended implantation sites.
- •Patients with a history of hypersensitivity to nickel.
- •Patients whose lung tumors are being monitored with MR imaging (MR imaging of the anchored transponders is safe but yields an image artifact around the anchored transponders).
- •Posterior lesions that would be >19cm distance from Calypso detector plate. Patients may be treated in the prone position in order to meet the required minimum distance.
- •Patients with any other medical condition or laboratory value that would, at the discretion of the investigator, preclude the patient from participation in this clinical study.
- •Patients who are deemed unable to safely undergo or tolerate flexible bronchoscopy
- •Patients who are unable to tolerate anesthesia or sedation
- •Patients enrolled in any other clinical studies the investigator believes to be in conflict with this investigation.
- •Female patients who are pregnant or nursing
研究组 & 干预措施
Calypso-based Deep Inspiration Breath Hold (DIBH)
This trial will investigate the feasibility of implanted anchored Beacon ® electromagnetic lung transponders (Calypso ®) to guide and monitor deep-inspiration breathhold (DIBH) treatments in patients with inoperable thoracic malignancies.
Bronchoscopic Calypso Beacon Implantation, Simulation - Free-breathing scan - 4D CT scan,- DIBH CT scan Radiation - Treatment setup, - Calypso signal recording, - RT treatment with DIBH with or without visual biofeedback Follow-up - 3 and 6 months after RT with diagnostic CT chest
干预措施: Calypso Beacon Implantation (Device)
结局指标
主要结局
Feasibility of Calypso Transponders
时间窗: 2 years
Feasibility is defined as completion of all treatments using the DIBH treatment plan and Calypso transponders.
次要结局
- Reproducibility(2 years)
- Measure the Residual Intrafraction Tumor Motion(2 years)