跳至主要内容
临床试验/NCT03546881
NCT03546881
终止
不适用

A Prospective Single Center Randomized Interventional Controlled Open Trial Comparing Patient and Staff Safety During Peripheral Endovascular Arterial Revascularisation Using Advanced Imaging Guidance Technology to Control Group Without Imaging Guidance.

Nantes University Hospital1 个研究点 分布在 1 个国家目标入组 77 人开始时间: 2018年6月18日最近更新:
适应症Arteriopathy

概览

阶段
不适用
状态
终止
入组人数
77
试验地点
1
主要终点
DAP (Dose Aera Product in Gy.cm²) by the end of the procedure,

概览

简要总结

Study the Patient and staff Safety regarding the radiation exposure during the procedure with and without the fusion imaging guidance technology in treatment of peripheral artery disease.

详细描述

The investigators are proposing a prospective, monocentric trial to assess the use of fusion imaging in peripheral endovascular revascularisation. The main aim of this research is to prove that using fusion imaging guidance during peripheral endovascular revascularisation improve the patient and staff safety in the theatre, through a reduction of radiation exposure.

Peripheral artery occlusive disease (PAOD) is a worldwide well known disease, with atherosclerosis as a leading cause. One third of patients with PAOD are symptomatic, typically presenting with claudication, and in a very much less proportion with critical limb ischemia. These last patients are high risk for major limb amputation without revascularisation. Once symptomatic PAOD diagnosed, a CT-scan is required to assess the anatomy and if indicated an endovascular revascularisation of the lower limbs arteries is performed. This minimally invasive procedure allows the improvement of the hemodynamic flow into the lower limb, by positioning one or several stents inside the diseased arteries through a femoral or an humeral access under live X-rays (fluoroscopy) guidance.

X-rays are good at showing bones and radio-opaque endovascular tools, but they do not show soft tissues like the arteries, and they produce flat (2D) images that superimpose all the 3D anatomical features. In order to see the arteries, physicians have to inject iodinated contrast during high quality imaging recording, which can be toxic for the kidneys, and increases the amount of radiation used. Consequently, the drawbacks of this mini-invasive procedure are the X-rays radiation exposure for both patients and medical staff, and the need of iodinated contrast injection that can lead to lifelong kidney problems. Reducing both in order to decrease their respective toxicities must be a priority for the endovascular therapist. Several studies including guidelines recall basic safety standards for protection against X-rays and iodinated contrast exposure.

One way to reduce both radiation and contrast use is to improve clinicians' perception of intraoperative 3D vascular anatomy. Advanced imaging techniques allow overlay of a 3D version of the aorta from a pre-operative CT scan (a 3D vascular mask) onto the live X-ray image creating a '3D roadmap' - a virtual reality that helps guide surgery. It has been proven that using fusion imaging guidance during aortic endovascular repair reduce both contrast and radiation dose, especially if the registration protocol is contrast and almost radiation free. The investigators have recently completed research showing that they are able to use an advanced imaging application to dramatically reduce our radiation dose for complex aneurysms.

Traditionally, this advanced imaging application is currently available only in modern expensive hybrid theatres, and not used in everyday practice during peripheral endovascular revascularisation procedures. However new technologies are about to supply similar imaging to any interventional equipment, which will change the way endovascular procedures are performed worldwide. That's why using fusion imaging guidance routinely as a standard of care may be part of good practice to improve patient and staff safety. However, to our knowledge, the impact of using fusion on radiation dose and contrast use has not been validated for peripheral endovascular procedures.

This trial will examine the clinical benefits of using fusion imaging guidance during peripheral endovascular revascularisation procedures based on the radiation exposure, as compared with procedures without imaging guidance. The design of the study is to compare a prospective single centre cohort of 88 consecutive patients scheduled for an endovascular peripheral procedure and randomised either as using the imaging guidance overlay, or to a control cohort of patients whose procedure will be performed without imaging guidance (standard of care).

This study is a Low risk and constraints study, because it's a standard care procedure with no additional risks.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Prevention
盲法
Single (Participant)

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Willing and able to give informed consent
  • Male or Female
  • Aged 18 or older
  • Have been scheduled for peripheral endovascular revascularisation of an occlusive arterial disease excluding isolated infra popliteal revascularisation
  • Who have had a pre-operative diagnostic CT scan
  • Able (in the investigator's opinion) and willing to comply with the study requirements
  • Covered by the French public health insurance system

排除标准

  • Female under the age of 50 years old.
  • Any other significant disease or disorder which, in the opinion of the Investigator, may either put the participants at risk because of participation in the study, or may influence the result of the study, or the participant's ability to participate in the study.
  • Any patient requiring an associated procedure: renal or mesenteric angioplasty.
  • Adult under guardianship or trusteeship

结局指标

主要结局

DAP (Dose Aera Product in Gy.cm²) by the end of the procedure,

时间窗: day 0, per procedure

The DAP is a surrogate measurement for the entire amount of energy delivered to the patient by the beam.

次要结局

  • AK (Air Kerma, in Gy)(day 0, per procedure)
  • Number of DSA (Digital Subtraction Angiography) runs(day 0, per procedure)
  • Radiation exposure to the operator (Sv).(day 0, per procedure)
  • Iodinated contrast volume (ml).(day 0, per procedure)
  • FT (Fluoroscopy Time, min).(day 0, per procedure)
  • Total operative time ( min)(day 0, per procedure)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验