Comparison of Diagnostic Performances of 3D FLAIR, DIR and PSIR Sequences in Optic Neuritis
试验速览
- 阶段
- 不适用
- 状态
- 招募中
- 发起方
- 入组人数
- 60
- 试验地点
- 1
- 主要终点
- Comparison of the radiologist's degree of diagnostic confidence based on the three sequences (3D FLAIR, 3D DIR and 3D PSIR sequences).
研究概览
简要总结
Ultimately improve the care of patients suffering from multiple sclerosis (1st cause of acquired non-traumatic disability in adults) and NMO spectrum diseases by using more efficient MRI sequences than the FLAIR sequence commonly used in detection of optic neuritis.
In the literature, many studies have already focused on comparing the sensitivity of detection of white matter demyelination plaques using FLAIR, PSIR or DIR sequences.
Some authors have shown better sensitivity of the PSIR sequence in the detection of demyelinating lesions of the marrow in multiple sclerosis compared to conventional sequences.
Others have shown better performance of the combined use of PSIR and DIR sequences compared to the FLAIR sequence in the detection of cortical lesions in multiple sclerosis.
However, in the context of optic neuritis, few comparative studies comparing these three sequences have been carried out:
A 2022 study showed better diagnostic sensitivity of optic neuritis of the DIR sequence compared to the FLAIR sequence.
A possible better diagnostic performance of a sequence not used in current practice in the detection of optic neuritis (PSIR and DIR sequences), would be possible to justify their use on a larger scale and ultimately improve patient care.
研究设计
- 研究类型
- Observational
- 观察模型
- Case Only
- 时间视角
- Retrospective
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Major subject (≥18 years old)
- •Subject suffering from multiple sclerosis or an NMO spectrum disease
- •Subject having received an MRI including 3D FLAIR, 3D DIR and 3D PSIR sequences
- •Brain MRIs of eligible subjects acquired between April 1, 2019 and November 30,
- •No opposition to the reuse of its data for scientific research purposes.
排除标准
- •Presence of opposition from the subject (and/or their legal representative if applicable) to the reuse of their data for scientific research purposes.
- •Artifacts not allowing satisfactory interpretation
结局指标
主要结局
Comparison of the radiologist's degree of diagnostic confidence based on the three sequences (3D FLAIR, 3D DIR and 3D PSIR sequences).
时间窗: One month after brain MRI
During their analysis, each investigator fills out an interpretation grid for each series, where they indicate the presence or absence of optic neuritis and the degree of confidence they attribute to it on a scale of 1 to 5. During their analysis, each investigator fills out an interpretation grid for each series, where they indicate the presence or absence of optic neuritis and the degree of confidence they attribute to it on a scale of 1 to 5. A score of 5 shows that the level of confidence is very good.
次要结局
未报告次要终点