Patients' entrance skin doses during percutaneous coronary intervention for chronic total occlusio
- Conditions
- chronic total occlusion
- Registration Number
- JPRN-UMIN000000490
- Lead Sponsor
- Radiological Protection During PCI Conference
- Brief Summary
The total fluoroscopic time was 45.0 +- 24.5 minutes (range: 10.3 - 113.0 minutes), and the total number of cine frames was 4558 +- 3440 (range: 855 - 22950). The maximum ESD for each patient was 3.2 +- 2.1 Gy (range: 0.5 - 10.2 Gy, median: 2.7 Gy).
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- Complete: follow-up complete
- Sex
- All
- Target Recruitment
- 120
Not provided
1. Patients scheduled for PCI, in which the upper arm may included in the irradiation field 2. Patient with skin lesion on the back which can be confused with radiation induced skin injury before the PCI procedure 3. Inability to sit before PCI prpcedure 4. Functional CTO
Study & Design
- Study Type
- Observational
- Study Design
- Not specified
- Primary Outcome Measures
Name Time Method patients' entrans skin dose
- Secondary Outcome Measures
Name Time Method data of PCI, radiation induced skin injury