临床试验/NCT02608281
NCT02608281已完成不适用

Clinical Study to Evaluate Diagnostic Accuracy of Low Dose Contrast Enhanced Dual Energy Mammography Imaging in Comparison to CE-MRI

Siemens Healthcare QT2 个研究点 分布在 1 个国家目标入组 110 人开始时间: 2015年11月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
110
试验地点
2
主要终点
Diagnostic accuracy of contrast enhanced dual energy mammography for breast cancer diagnosis

研究概览

简要总结

Clinical study to evaluate diagnostic accuracy of low dose contrast enhanced dual energy mammography imaging (CEDEM+PRIME) in comparison with CE-MRI The primary objective of this clinical study is to assess diagnostic accuracy in breast cancer detection in Contrast Enhanced Dual Energy Mammography compared to CEMRI. Sensitivity and specificity will be compared for both modalities.

详细描述

STUDY OBJECTIVES The primary objective of this clinical study is to assess the value of low-dose CEDEM in comparison with CE-MRI. The diagnostic accuracy in breast cancer detection of low dose CEDEM will be evaluated.

Investigator plans to explore the diagnostic quality of 4 standard view bilateral dual energy subtracted images compared to CE-MRI in a blinded reader study. A goal is to evaluate, whether sensitivity and specificity of low-dose CEDEM are comparable with breast MRI.

Subjects will be asked before diagnostic workup to participate in this clinical study. Approximately 80 subjects scheduled for a diagnostic CE-MRI (i.e., based on screening mammography classified as BI-RADS® 0, 4 or 5), will be eligible to participate in this study and will undergo a follow up 4 view bilateral low dose contrast enhanced mammography procedure.

Radiologically, subjects included in the study population will have even distribution of masses, clusters of microcalcifications, and architectural distortions as given by the nature of breast cancer development.

The study population will include all breast compositions. Diagnostic CE-MRI Examination If eligible, subjects with a positive or incomplete screening mammogram (BI-RADS 0, 4 or 5) will undergo a CE-MRI of the breast. MRI examinations will be performed on a 3 Tesla scanner (Tim trio, Siemens) with a dedicated 16 channel breast coil. A combination of high temporal and high spatial resolution imaging protocol will be used. All patients will be examined in the prone position and contrast agent (0.2mmol / body weight, GD-DOTA) will be administered i.v. as a bolus followed by a 20 ml saline flush.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
21 Years 至 —(Adult, Older Adult)
性别
Female
接受健康志愿者

入选标准

  • Females at least 21 years of age or older
  • A screening mammogram classified as BI-RADS® 0, 4 or 5 followed by a diagnostic CE-MRI and a histological verification of a given lesions either by needle biopsy or open surgery
  • Signed informed consent after receiving a verbal and written explanation of the purpose and nature of this clinical study

排除标准

  • Pregnant or possible pregnant as well as lactating women
  • Have mammographic evidence of previous breast surgery, prior radiation to the breast, needle projection or pre-biopsy markings are evident on the mammogram
  • Breast implants
  • Patients who will undergo neo-adjuvant chemotherapy (BI-RADS 6)
  • Inmates or mentally disabled patient.
  • Renal insufficiency or contrast agent allergy
  • Patients who participated in other clinical studies within the last 12 months

研究组 & 干预措施

CEDEM

Other

diagnostic contrast enhanced Dual Energy mammograms after Iodine based contrast media administration compared to CE MRI

干预措施: CONTRAST ENHANCED DUAL ENERGY (CEDEM) (Device)

结局指标

主要结局

Diagnostic accuracy of contrast enhanced dual energy mammography for breast cancer diagnosis

时间窗: 24 months

Difference in accuracy of 11% comparing a 4-view contrast-enhanced dual energy imaging to CE-MRI assuming 11% discordant rate in the diagnosis

次要结局

  • sensitivity, specificity and the lesion-level ROC area.(24 months)

研究者

发起方
Siemens Healthcare QT
申办方类型
Industry
责任方
Sponsor