Ultrasonographic Evaluation of Intraoperative Optic Nerve Sheath Diameter Changes in Patients Undergoing Laparoscopic Surgery
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 55
- 试验地点
- 2
- 主要终点
- Evaluation of optic nerve sheath diameter
研究概览
简要总结
Laparoscopic surgery is a widely used alternative to open surgery; Advantages include reduced bleeding and pain intensity, shorter hospital stay, and improved cosmetic results.
Laparoscopic surgery involves the creation of a carbon dioxide (CO2) pneumoperitoneum to facilitate a clear surgical view, which can result in increased intracranial pressure (ICP).
Ultrasonographic measurement of optic nerve sheath diameter (ONSD) is a simple, non-invasive, yet reliable technique for ICP assessment.Ultrasonographic assessment of optic nerve sheath diameter (ONSD) has been proposed as a non-invasive measurement of intracranial pressure.
详细描述
Ultrasonographic measurement of optic nerve sheath diameter (ONSD) is a simple, non-invasive, yet reliable technique for ICP assessment. Previous studies have demonstrated that ultrasonographic measurement of ONSD correlates with the degree of ICP and can detect intracranial hypertension in a variety of clinical settings.
It was planned to measure the optic nerve sheath throughout the surgery with the help of a linear ultrasound probe.
Ultrasonographically, in each measurement, the optic nerve sheath diameter (ONSD) was detected 3 mm behind the entry point of the optic nerve into the globe in both eyes. ONSD will be measured bilaterally 3 mm behind the papilla. It will be evaluated by transverse measurement for each optic nerve.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Diagnostic
- 盲法
- None
盲法说明
Single(Participant)
入排标准
- 年龄范围
- 18 Years 至 75 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •18-75 aged patients
- •American Society of Anesthesiologists Classification (ASA) I-II-III patients
- •Patients undergoing laparoscopic surgery
排除标准
- •American Society of Anesthesiologists Classification (ASA) IV-V patients
- •Those with known ophthalmic disease
- •Those with a history of ophthalmic surgery
- •Those with any known neurological disorder
- •History of intracranial hypertension
- •Patients who will undergo open abdominal surgery
研究组 & 干预措施
Optic nerve sheath measurement
Optic nerve sheath diameter (ONSD) was detected 3 mm behind the entry point of the optic nerve into the globe in both eyes in each ultrasonographic measurement. ONSD was measured bilaterally 3 mm posterior to the papilla. Transverse measurements were made for each optic nerve.
干预措施: Optic nerve sheath measurement (Other)
结局指标
主要结局
Evaluation of optic nerve sheath diameter
时间窗: During the operation
Ultrasound measurement of optic nerve sheath diameter during laparoscopic surgery
次要结局
未报告次要终点
研究者
Sevim Cesur
Associate professor
Kocaeli University
