A Comparison of McGrath, Pentax and Macintosh Laryngoscopes for Nasotracheal Intubation in Pediatrics
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 108
- 试验地点
- 2
- 主要终点
- time to intubation
研究概览
简要总结
Videolaryngoscope provide better view of the larynx. This better view could improve the navigation of endotracheal tube in nasotracheal intubation. Contrast to the improved result in adult, one previous report using Glidescope in children did not show better performance than direct laryngoscope. The aim of this study is to compare the performance of McGrath, Pentax and Macintosh laryngoscope for nasotracheal intubation in children.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Supportive Care
- 盲法
- None
入排标准
- 年龄范围
- 1 Year 至 10 Years(Child)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •American Society of Anesthesiologist physical status class I, II
排除标准
- •abnormality of airway
- •bleeding tendency
研究组 & 干预措施
Macintosh laryngoscope
Nasotracheal intubation by Macintosh laryngoscope
干预措施: Macintosh laryngoscope (Device)
McGrath videolaryngoscope
Nasotracheal intubation by McGrath videolaryngoscope
干预措施: McGrath videolaryngoscope (Device)
Pentax videolaryngoscope
Nasotracheal intubation by Pentax videolaryngoscope
干预措施: Pentax videolaryngoscope (Device)
结局指标
主要结局
time to intubation
时间窗: 2 min
Time from nasotracheal tube passing nose until confirmation of tracheal intubation by end-tidal carbon dioxide will be measured
次要结局
- intubation difficulty scale(immediately after intubation)
研究者
yun jeong chae
Associate Professor
Ajou University School of Medicine