MedPath

Circadian Ocular Perfusion Pressure and Ocular Blood Flow

Registration Number
NCT00800540
Lead Sponsor
Alcon Research
Brief Summary

The purpose of this study was to compare the short term effects of two intraocular pressure (IOP) lowering medications on ocular perfusion pressure (OPP), ocular blood flow, intraocular pressure, and blood pressure in patients with glaucoma. Ocular perfusion pressure (OPP) is defined as the difference between arterial blood pressure (diastolic and systolic) and intraocular pressure. The primary efficacy assessment is based on diastolic ocular perfusion pressure.

Detailed Description

Not available

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
35
Inclusion Criteria
  • Sign Informed Consent.
  • Diagnosis of open-angle glaucoma in at least one eye.
  • Requires more than one IOP-lowering medication.
  • IOP measurements at Screening, Safety, and Eligibility/Period 1 Baseline Visits as specified in protocol.
  • Able to discontinue all IOP-lowering medication prior to Eligibility Visit and for 4 weeks between treatment periods.
  • Willing to complete all required study visits.
  • Other protocol-defined inclusion criteria may apply.
Exclusion Criteria
  • Female of child-bearing potential if pregnant, lactating, or not using highly effective birth control measures.
  • Severe central visual field loss in either eye.
  • Previous glaucoma surgery in the study eye.
  • Intraocular surgery in the study eye within 3 months prior to the Screening Visit.
  • Wears contact lenses.
  • Allergy/hypersensitivity to study medication.
  • Cannot safely discontinue use of glucocorticoid medication.
  • Uses medication that could affect IOP or blood pressure.
  • Recent use of high-dose aspirin.
  • Bronchial asthma or severe chronic obstructive pulmonary disease.
  • Diabetic retinopathy.
  • Any abnormality preventing reliable tonometry.
  • Any severe illness or condition unsuitable for the study, in the opinion of the investigator.
  • Other protocol-defined exclusion criteria may apply.

Study & Design

Study Type
INTERVENTIONAL
Study Design
CROSSOVER
Arm && Interventions
GroupInterventionDescription
AZARGA/COMBIGANBrinzolamide 10 mg/ml/Timolol 5 mg/ml eye drops suspensionAZARGA, followed by COMBIGAN, as randomized. Each fixed combination instilled in the study eye, one drop twice daily (9:00 and 21:00), for six weeks, with a 4-week washout period separating the two treatment periods.
AZARGA/COMBIGANBrimonidine 20 mg/ml/Timolol 5 mg/ml eye drops solutionAZARGA, followed by COMBIGAN, as randomized. Each fixed combination instilled in the study eye, one drop twice daily (9:00 and 21:00), for six weeks, with a 4-week washout period separating the two treatment periods.
COMBIGAN/AZARGABrinzolamide 10 mg/ml/Timolol 5 mg/ml eye drops suspensionCOMBIGAN, followed by AZARGA, as randomized. Each fixed combination instilled in the study eye, one drop twice daily (9:00 and 21:00), for six weeks, with a 4-week washout period separating the two treatment periods.
COMBIGAN/AZARGABrimonidine 20 mg/ml/Timolol 5 mg/ml eye drops solutionCOMBIGAN, followed by AZARGA, as randomized. Each fixed combination instilled in the study eye, one drop twice daily (9:00 and 21:00), for six weeks, with a 4-week washout period separating the two treatment periods.
Primary Outcome Measures
NameTimeMethod
Mean Change From Baseline in Overall Diastolic Ocular Perfusion Pressure at Week 6Week 0, Week 6 (period-based)

Diastolic ocular perfusion pressure (DOPP) is defined as the difference between diastolic arterial pressure and intraocular pressure. Diastolic arterial pressure was measured with a calibrated automated sphygmomanometer. Intraocular pressure was measured with a calibrated pneumatonometer. A lower DOPP indicates a lower optic blood supply, which can be a risk factor for developing glaucoma or glaucoma progression (leading to optic nerve damage).

Secondary Outcome Measures
NameTimeMethod
Mean Change From Baseline in Circadian Diastolic Ocular Perfusion Pressure at Week 6Week 0, Week 6 (period-based)

Circadian diastolic ocular perfusion pressure (COPP) is defined as the variations in diastolic OPP during the day and night. Diastolic ocular perfusion pressure was calculated at 7 timepoints over a 24-hour period. Changes in the diastolic ocular perfusion pressure rhythm throughout the day (outside the normal range) may affect glaucoma progression.

Mean Change From Baseline in Mean Flow Value in the Superotemporal Peripapillary Retina at Week 6Week 0, Week 6 (period-based)

Retinal perfusion assessments were made using Heidelberg Retinal Flowmetry (HRF). Assessments were made at 4 timepoints over a 12-hour period. Intensity of blood flow was measured in arbitrary units, with a higher number indicating an increased blood flow. An increase in ocular blood flow may reduce the risk of glaucoma progression.

Mean Change From Baseline in Mean Flow Value in the Inverotemporal Peripapillary Retina at Week 6Week 0, Week 6 (period-based)

Retinal perfusion assessments were made using Heidelberg Retinal Flowmetry (HRF). Assessments were made at 4 timepoints over a 12-hour period. Intensity of blood flow was measured in arbitrary units, with a higher number indicating an increased blood flow. An increase in ocular blood flow may reduce the risk of glaucoma progression.

Mean Change From Baseline in Intraocular Pressure (IOP) at Week 6Week 0, Week 6 (period-based)

Intraocular pressure (IOP) is defined as the fluid pressure inside the eye. Intraocular pressure was measured with a calibrated pneumatonometer at 7 time points over a 24-hour period. High IOP (outside the normal range) can be a risk factor for developing glaucoma or glaucoma progression (leading to optic nerve damage).

Mean Change From Baseline in Diastolic Blood Pressure at Week 6Week 0, Week 6 (period-based)

Blood pressure is defined as the pressure exerted by circulating blood upon the walls of the blood vessels, that is, arterial pressure of the systemic circulation of blood. Diastolic blood pressure refers to the minimum pressure, that is, the pressure between heartbeats. Diastolic glood pressure was measured at 7 timepoints in a 24-hour period using a calibrated sphygmomonometer. Higher blood pressure (outside the normal range) can be a risk factor for developing cardiovascular events, such as heart attack, stroke, or heart failure. Lower blood pressure (outside the normal range) can be a risk factor for dizziness or fainting.

Mean Change From Baseline in Systolic Blood Pressure at Week 6Week 0, Week 6 (period-based)

Blood pressure is defined as the pressure exerted by circulating blood upon the walls of the blood vessels, that is, arterial pressure of the systemic circulation of blood. Systolic blood pressure refers to the maximum pressure, that is, the pressure while the heart is beating, and was measured at 7 timepoints in a 24-hour period using a calibrated sphygmomonometer. Higher blood pressure (outside the normal range) can be a risk factor for developing cardiovascular events, such as heart attack, stroke, or heart failure. Lower blood pressure (outside the normal range) can be a risk factor for dizziness or fainting.

Mean Change From Baseline in Vascular Resistance in the Central Retinal Artery at Week 6Week 0, Week 6 (period-based)

Vascular resistance in the central retinal artery was assessed using Color Doppler Imaging (CDI). Assessments were made at 7 time points over a 24-hour period.

Mean Change From Baseline in Vascular Resistance in the Ophthalmic Artery at 6 WeeksWeek 0, Week 6 (period-based)

Vascular resistance in the ophthalmic artery was assessed using Color Doppler Imaging (CDI). Assessments were made at 7 time points over a 24-hour period.

Mean Change From Baseline in End Diastolic Velocity in the Ophthalmic Artery at Week 6Week 0, Week 6 (period-based)

End diastolic velocity in the ophthalmic artery was assessed using Color Doppler Imaging (CDI). Assessments were made at 7 time points over a 24-hour period.

Mean Change From Baseline in Peak Systolic Velocity in the Ophthalmic Artery at Week 6Week 0, Week 6 (period-based)

Peak systolic velocity in the ophthalmic artery was assessed using Color Doppler Imaging (CDI). Assessments were made at 7 time points over a 24-hour period.

Mean Change From Baseline in Peak Systolic Velocity in the Central Retinal Artery at Week 6Week 0, Week 6 (period-based)

Peak systolic velocity in the central retinal artery was assessed using Color Doppler Imaging (CDI). Assessments were made at 7 time points over a 24-hour period.

Trial Locations

Locations (1)

Contact Alcon Call Center at 1-888-451-3937 For Trial Locations

🇺🇸

Fort Worth, Texas, United States