Effects of Parental Holding on Pain Response in Young Children During Cystometry: a Randomized Controlled Trial
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 64
- 试验地点
- 1
- 主要终点
- Behavioral pain response change measured using the FLACC(Faces, Legs, Activity, Crying, and Consolability) scale between each time point (immediately, 3 min, and 10 min after urethral catheter insertion).
研究概览
简要总结
Cystometry is essential for diagnosis and treatment plans by identifying the causes of lower urinary tract symptoms and objectively evaluating bladder functions in diseases such as neurogenic bladder, voiding dysfunction, and vesicoureteral reflux. Children may experience pain during this invasive procedure of inserting the urethra catheter. Furthermore, infants aged ≥ 6 months may feel pain from an unfamiliar and unnatural environment as they experience stranger anxiety. This experience can have a negative physical and emotional impact on children, and uncooperative behavioral reactions caused by pain can hinder the procedure. In this regard, parental holding is known as effective non-pharmacological procedural pain management in children. Although the International Children's Continence Society has advised performing cystometry while holding the infant as an effective non-pharmacological pain management method, there is insufficient evidence to support this. So, this study aimed to analyze the effect of parental holding on reducing pain in children during cystometry.
详细描述
This is an experimental study in a randomized controlled pre-posttest design. During cystometry, participants in the experimental group are placed on the parents' laps and held in the parents' arms. Participants in the control group are laid down on the examination table. The behavioral (FLACC scale) and physiological (oxygen saturation and heart rate) pain responses are measured at three time points (immediately, 3 min, and 10 min after urethral catheter insertion).
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Supportive Care
- 盲法
- None
入排标准
- 年龄范围
- 6 Months 至 18 Months(Child)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •The children aged 6-18 months.
- •The children who undergo cystometry for the first time.
- •The children who undergo cystometry with their parents.
排除标准
- •The child who is premature or has a low birth weight
- •The primary caregiver is not the participant's parent
- •The child who has unstable vital signs
- •The child is expected to have neurological or sensory impairments (e.g., spinal cord inflammation, spina bifida).
结局指标
主要结局
Behavioral pain response change measured using the FLACC(Faces, Legs, Activity, Crying, and Consolability) scale between each time point (immediately, 3 min, and 10 min after urethral catheter insertion).
时间窗: Change from immediately, 3 minutes, and 10 minutes after urethral catheter insertion
Behavioral pain response refers to facial expression changes, body movements, postures, and crying on pain stimuli. This is measured using the FLACC scale developed to evaluate acute pain in children. According to the FLACC scale, pain is rated using a total of five subcategories (Faces, Legs, Activity, Crying, and Consolability) on a scale of 0-2, and the scores are summed (range 0 to 10).
Physiological pain responses change measured using heart rate (beats/min) . Change between each time point (immediately, 3 min, and 10 min after urethral catheter insertion), automatically measured by a Pulse oximeter.
时间窗: Change from immediately, 3 minutes, and 10 minutes after urethral catheter insertion
The heart rate (beats/minute) is automatically measured by a Nellcor OxiMax N-560 Pulse oximeter (Nellcor Puritan Bennett LLC, USA), and a Nellcor SpO2 sensor (Nellcor Puritan Bennett LLC, USA) is attached to the participants' toes.
Physiological pain responses change measured using oxygen saturation (%/min). Change between each time point (immediately, 3 min, and 10 min after urethral catheter insertion), automatically measured by a Pulse oximeter.
时间窗: Change from immediately, 3 minutes, and 10 minutes after urethral catheter insertion
The oxygen saturation (%/minute) is automatically measured by a Nellcor OxiMax N-560 Pulse oximeter (Nellcor Puritan Bennett LLC, USA), and a Nellcor SpO2 sensor (Nellcor Puritan Bennett LLC, USA) is attached to the participants' toes.
次要结局
未报告次要终点
