Acute Effect of Whole Body Vibration on Reaction Speed and Proprioception in the Upper Extremity in Healthy Subjects
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 62
- 试验地点
- 2
- 主要终点
- Reaction Rate Evaluation with Sway Medical Smartphone Application
研究概览
简要总结
It will be determined whether the application of whole body vibration has an immediate effect on upper extremity reaction speed and proprioception.
详细描述
Muscles and tendons are among the mechanisms affected by whole body vibration. In this way, it is thought that TVV indirectly affects the reaction speed of individuals. In the light of this information, this study was planned to investigate how whole body vibration application affects proprioception and reaction speed. The reaction rate and instantaneous effect of the virion given at 30 Hz and 2 mm amplitude in the push-up position on proprioception will be investigated. The aim of this study is to investigate the instantaneous effect of whole body vibration on reaction speed and proprioception in the upper extremity in healthy individuals.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Basic Science
- 盲法
- None
盲法说明
In statistical analysis, blinding will be done before and after the application.
入排标准
- 年龄范围
- 18 Years 至 25 Years(Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •Healthy individuals between the ages of 18-25
- •Those who do not have any orthopedic problems in the upper extremity
- •Individuals without any neurological problems
- •Those who volunteer to participate in the study
排除标准
- •Those who have vertigo
结局指标
主要结局
Reaction Rate Evaluation with Sway Medical Smartphone Application
时间窗: All measurements take 30 minutes for each individual, before and immediately after the application on the same day.
The person will sit comfortably on a chair and hold the smartphone with the thumbs on both sides. When the orange screen appears, the phone should quickly rotate the screen in the desired direction. Once you will do the test to learn the application. Then, the application is made three times and the reaction rate is calculated by taking the average time of these three applications.
Upper extremity proprioception measurement
时间窗: All measurements take 30 minutes for each individual, before and immediately after the application on the same day.
Elbow flexion, shoulder flexion and abduction 30 and 60 degree angles were measured with a digital goniometer. The elbow and shoulder positions were brought to the desired angle and they were asked to return to the same angle. The angle of deviation was recorded.
Nelson Hand Reaction Test
时间窗: All measurements take 30 minutes for each individual, before and immediately after the application on the same day.
The participant is asked to sit in the chair with the forearm and hand comfortably resting on the table. The tips of the thumb and index finger are positioned 8-10 cm away from the table, with the tops of the thumb and index finger parallel to each other. The tester asks the individual to hold the ruler between his thumb and index finger. At the same time, the patient is asked to look directly at the middle point of the ruler while holding it between his fingers. As soon as the ruler is released, the person is told to catch the ruler with his thumb and forefinger. The ruler is left and the numerical value on the upper edge of the subject's thumb, where the subject grasps the ruler, is read and recorded.
次要结局
未报告次要终点
研究者
Çağtay Maden
Assistant professor
Gaziantep Islam Science and Technology University
