Conventional Endoscopic Techniques Versus EndoRotor® System for Necrosectomy of Walled of Necrosis

Not Applicable
Recruiting
Conditions
Acute Pancreatitis
Necrosis; Pancreas, Acute (Infectious)
Interventions
Procedure: Conventional endoscopic devices (according to standards of care)
Device: EndoRotor® System (Interscope, Inc., Northbridge, MA USA),
Registration Number
NCT04814693
Lead Sponsor
Erasmus Medical Center
Brief Summary

In acute pancreatitis, approximately 20% of the cases result in severe necrotizing pancreatitis which is associated with significant morbidity and mortality. Necrotizing pancreatitis is characterized by the development of an acute necrotic collection and as this collection persists beyond 4 weeks, walled off necrosis (WON) encapsulates the collection. To date, this is treated by the step-up approach, which contains percutaneous drainage and minimally invasive video assisted retroperitoneal debridement (VARD) or endoscopic ultrasound (EUS) guided drainage followed by direct endoscopic necrosectomy (DEN). Different DEN techniques are available for the treatment of WON, however, there is a lack of effective endoscopic instruments to perform DEN. Recently, the first dedicated alternative to conventional DEN has been cleared for use, namely the EndoRotor® Resection System. This device is a powered mechanical debridement device intended for use in endoscopic procedures to resect and remove necrotic debris during DEN for WON. Previous (pilot and feasibility) studies showed promising results in terms of the amount of procedures, adverse events and length of hospital stay.

Therefore, aim of this study is to assess the performance of the EndoRotor, as compared to conventional endoscopic techniques, for direct endoscopic necrosectomy (DEN) of walled off necrosis (WON) in a randomized controlled trial.

Detailed Description

Not available

Recruitment & Eligibility

Status
RECRUITING
Sex
All
Target Recruitment
60
Inclusion Criteria
  • Patients with symptomatic pancreatic necrosis due to acute pancreatitis that have an indication to undergo endoscopic necrosectomy after having undergone EUS-guided drainage.

    a. Stent must be in place for a minimum of 2 days prior to the DEN procedure.

  • Patients who can tolerate repeat endoscopic procedures.

  • Subjects with the ability to understand the requirements of the study, who have provided written informed consent, and who are willing and able to return for the required follow-up assessments.

  • ASA classification < 5.

Exclusion Criteria
  • Documented pseudoaneurysm > 1 cm within the WON.
  • Subject unable or unwilling to provide informed consent.
  • Intervening gastric varices or unavoidable blood vessels within the WON access tract (visible using endoscopy or endoscopic ultrasound).
  • Coagulation disorders or anti-coagulant therapy which cannot be discontinued (aspirin allowed).
  • Any condition that in the opinion of the Investigator would create an unsafe clinical situation or stent placement that would not allow the patient to safely undergo an endoscopic procedure.
  • Pregnant or lactating women or women of childbearing potential who do not employ a reliable method of contraception as judged by the Investigator, and/or are not willing to use reliable contraception for the duration of study participation.
  • Patient is enrolled in another trial that could interfere with the endpoint analyses of this trial.
  • Prior necrosectomy on existing collection.
  • Greater than 2 pancreatic / extra-pancreatic fluid collections.

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
Control armConventional endoscopic devices (according to standards of care)Subjects randomized to the control device arm will undergo conventional DEN as per the standard of care. Investigators will choose conventional DEN instruments according to their preference.
Interventional armEndoRotor® System (Interscope, Inc., Northbridge, MA USA),Subjects randomized to the control device arm will undergo treatment with the EndoRotor System, which is a powered debridement tool intended for use in endoscopic procedures to resect and remove necrotic debris during direct endoscopic necrosectomy (DEN) for walled-off necrosis. The system consists of capital components including a power console, roll stand, vacuum pump, and foot control; as well as disposable components including a single-use catheter, purge kit, and suction bag. The EndoRotor System has CE-Mark 613797 and is cleared for use by the FDA in the United States.
Primary Outcome Measures
NameTimeMethod
The number of DEN procedures required to achieve resolution of WONDuring a 6 month follow up period

1. Resolution is defined as clinical improvement of WON symptoms precluding the need for additional endoscopic or surgical interventions.

2. Clinical improvement is defined according to the criteria used in the PANTER trial and TENSION trial.8,15 "Clinical improvement" was defined as:

i. Improved function of at least two organ systems (i.e. circulatory, pulmonary, renal) according to the Investigator's medical judgement within 72 hours, or; ii. At least 10% improvement of two out of three parameters of infection (i.e. C-reactive protein, leucocyte count or temperature) within 72 hours.

Secondary Outcome Measures
NameTimeMethod
Conversion to surgery defined as number of subject that require surgical intervention as a result of DEN failure as assessed by the Investigator during the index procedure through the 6 month post necrosectomy follow-up visitDuring a 6 month follow up period

In case of conversion to surgery, reason for conversion and type of surgical procedure

Adverse eventsDuring a 6 month follow up period

The occurrence of all adverse events measured from the Index Procedure through the 6 Month Post Necrosectomy Follow-up Visit

Length of hospitalizationDuring a 6 month follow up period

Length of hospitalization measured in days from the Index Procedure, including days in intensive care unit (ICU) vs. standard in-patient hospitalization

Procedure timeDuring a 6 month follow up period

Measured in minutes from the point of per-oral scope insertion to scope removal (scope-in / scope-out).

Subject Quality of LifeDuring a 6 month follow up period

Subject quality of life (QOL) as assessed by a SF-36 questionnaire performed at Baseline, Discharge, and at the 1, 3, and 6 Month Post Necrosectomy Follow-up Visits.

Mean total cost of care per subjectDuring a 6 month follow up period

Mean total cost of care per subject including: procedure costs, debridement devices used during the procedure, and inpatient hospital stay from the date of procedure to the date of discharge based on reimbursement fee structure expressed in US dollars, Euros or UK Pounds respectively.

a. Procedure costs will be based on the cost of an endoscopic retrograde cholangiopancreatography (ERCP) which covers room, X-ray, sedation, personnel, and other materials.

Percent reduction in WON collection volume (cm3)During a 6 month follow up period

Assessed by contrast enhanced computed tomography (CECT) scan or magnetic resonance imaging (MRI) (Baseline vs. completion of necrosectomy). Percent reduction in WON collection volume (cm3) as assessed by contrast enhanced computed tomography (CECT) scan or magnetic resonance imaging (MRI) (Baseline vs. completion of necrosectomy).

1. Endoscopic ultrasound (EUS) may be used for imaging only when a subject is contraindicated for MRI and CECT.

2. WON collection volume will be measured as follows:

i. Length = longest diameter in cm/mm in the axial plane (left - right) ii. Width = the longest diameter in cm/mm (frontal - dorsal) in the same axial plane as the length, perpendicular on the longitudinal axis.

iii. Height = longest diameter in cm/mm on coronal plane (cranial - caudal)

Debridement timeDuring a 6 month follow up period

Measured in minutes from the start of the debridement procedure to completion of the debridement procedure, including time to swap devices.

The number of device deficiencies, defined as any inadequacy of a medical device with respect to its identity, quality, durability, reliability, safety, or performance including malfunction, use errors, and inadequate labelingprocedureDuring a 6 month follow up period

Assessed by the Investigator during each DEN procedure. This may include malfunctions, use error, or inadequacy in the information supplied by the manufacturer

Trial Locations

Locations (12)

California Pacific Medical Center

🇺🇸

San Francisco, California, United States

University of Alabama Medical Center

🇺🇸

Birmingham, Alabama, United States

Thomas Jefferson University Hospital

🇺🇸

Philadelphia, Pennsylvania, United States

Evangelical Hospital

🇩🇪

Düsseldorf, Germany

Copenhagen University Hospital

🇩🇰

Hvidovre, Denmark

Humanitas Reserach Hospital & Humanitas University

🇮🇹

Milano, Italy

University of Frankfurt

🇩🇪

Frankfurt, Germany

Fondazione Policlinico Universitario Agostino Gemelli IRCCS

🇮🇹

Roma, Italy

Charlotte van Veldhuisen

🇳🇱

Amsterdam, Netherlands

Amsterdam University Medical Center

🇳🇱

Amsterdam, Netherlands

St. Antonius Hospital

🇳🇱

Nieuwegein, Netherlands

Central Manchester University Hospital

🇬🇧

Manchester, United Kingdom

© Copyright 2025. All Rights Reserved by MedPath