NCT04985279Active, not recruitingNot Applicable

Position and Angle Marking System (PAMS) for Ultrasound-guided Neuraxial Procedures

KK Women's and Children's Hospital1 site in 1 country30 target enrollmentStarted: September 7, 2021Last updated:
Conditions
Interventions

Trial Snapshot

Phase
Not Applicable
Status
Active, not recruiting
Sponsor
Enrollment
30
Locations
1
Primary Endpoint
Satisfaction survey of simulated patients and operators

Study Overview

Brief Summary

Epidural anaesthesia involves the administration of numbing medication (local anaesthetics) close to the spinal canal, and is regarded as the best method for providing pain relief during labour and childbirth. The use of ultrasound to guide epidural insertion and placement has been shown to improve pain relief and reduce the risk of complications.

However, after identifying the desired needle insertion site via ultrasound, current practice involves demarcating the insertion site using marker pens, which is time-consuming, inaccurate, and may be inadvertently removed by skin sterilisation. Furthermore, the desired needle angulation determined by ultrasound cannot be accurately measured and maintained during the epidural procedure. Both issues limit the benefits of using ultrasound to guide the epidural procedure.

To address these issues, the investigators developed a Position and Angular Marking System (PAMS) that attaches on to the ultrasound probe. When the desired insertion site is identified by ultrasound, the doctor gently presses PAMS into the patient's back to create skin indentations demarcating the needle insertion point. These indentations are not affected by skin sterilisation, and may improve accuracy and reduce the time taken to perform the epidural procedure. Next, the angle between the ultrasound probe and the patient's back can be measured using PAMS, and this angle can be maintained using a needle guide during the epidural procedure.

The purpose of this randomised study is to evaluate the usability of PAMS and to identify areas for further improvement.

This study will involve up to 10 healthy simulated patients, and up to 30 volunteer ultrasound operators. After undergoing a standardised training session with a mannequin, the ultrasound operators will be randomly assigned to perform skin marking on the simulated patients as though they are performing an ultrasound-guided epidural anaesthesia procedure (no needle puncture will be made) using either PAMS, or standard clinical practice with marker pens. After completing the procedure, the ultrasound operators will cross over and perform the procedure again using either PAMS or standard clinical practice with marker pens.

Both the ultrasound operators and simulated patients will be asked to complete satisfaction and usability surveys regarding their experience with the procedures.

Detailed Description

The volunteer ultrasound operators are women's anaesthesiologists trained in the use of ultrasound-guided neuraxial procedures.

Simulated patients are healthy volunteers from other departments, without spine abnormalities.

The ultrasound operators will be asked to complete a questionnaire regarding your prior experience with neuraxial ultrasonography and undergo structured training on the use of PAMS using a mannequin. Next, they will be asked to perform the following two procedures (the order at which they will perform the procedures will be randomised):

  1. Ultrasound scan using PAMS
  • After attaching PAMS to the ultrasound probe, they will perform a lumbar ultrasound scan on a simulated patient to identify the desired needle insertion site and gently press PAMS into the simulated patient's back to create skin indentations demarcating the desired needle insertion site.
  • Next, adjust the angulation of the ultrasound probe to optimise the image of the simulated patient's lumbar spine, and read the angle between the ultrasound probe and patient's back off a graduated scale.
  • Remove the ultrasound probe, and position the needle-insertion guide corresponding to the skin indentations. Needle angulation can be simulated by mounting a blunt needle on to the insertion guide.
  • Finally, they will be asked to complete a usability questionnaire.
  1. Ultrasound scan without PAMS (standard clinical practice)

Study Design

Study Type
Interventional
Allocation
Randomized
Intervention Model
Crossover
Primary Purpose
Treatment
Masking
None

Masking Description

No masking involved.

Eligibility Criteria

Ages
18 Years to — (Adult, Older Adult)
Sex
All
Accepts Healthy Volunteers
Yes

Inclusion Criteria

  • •Ultrasound operators
  • •Inclusion Criteria:
  • •Anaesthesiologists
  • •Trained in the use of ultrasound-guided neuraxial procedures

Exclusion Criteria

  • •No experience with ultrasound-guided neuraxial procedures
  • •Simulated patients
  • •Inclusion Criteria:
  • •Healthy, no significant medical comorbidity (American Society of Anesthesiologists Physical Status I or II)
  • •No spinal abnormalities, or previous spinal surgery
  • •Exclusion Criteria:
  • •Significant spinal abnormality
  • •Previous spinal surgery

Arms & Interventions

Standard clinical practice

Active Comparator
  • Lumbar ultrasound scan will be performed to identify the desired needle insertion site, followed by demarcation using skin markers.
  • The angulation of the ultrasound probe will be adjusted to optimise the image of the simulated patient's lumbar spine.
  • The ultrasound probe will be removed and needle insertion simulated by touching the tip of a blunt needle to the patient's back, at the desired angle.
  • A usability questionnaire regarding the procedure will be completed.

Intervention: Standard clinical practice (Device)

Position and Angle Marking System (PAMS)

Experimental
  • PAMS will be attached to the ultrasound probe.
  • Lumbar ultrasound scan will be performed to identify the desired needle insertion site, followed by demarcation by gentle pressing PAMS into the simulated patient's back to create skin indentations.
  • The angulation of the ultrasound probe will be adjusted to optimise the image of the simulated patient's lumbar spine, and the angle read off a graduated scale.
  • The ultrasound probe will be removed and needle insertion simulated by touching the tip of a blunt needle to the patient's back, at the desired angle.
  • A usability questionnaire regarding the procedure will be completed.

Intervention: Position and Angle Marking System (Device)

Outcomes

Primary Outcomes

Satisfaction survey of simulated patients and operators

Time Frame: Immediately after performing the procedure

Satisfaction and feedback regarding the respective procedures

Secondary Outcomes

  • Time taken to perform procedure(Immediately after performing the procedure)

Investigators

Sponsor
KK Women's and Children's Hospital
Sponsor Class
Other Gov
Responsible Party
Principal Investigator
Principal Investigator

Sng Ban Leong

Senior Consultant

KK Women's and Children's Hospital