跳至主要内容
临床试验/NCT04187924
NCT04187924已完成不适用

Effects of the Addition of the SIMEOX Device on Autogenic Drainage in Patients With Cystic Fibrosis

Cliniques universitaires Saint-Luc- Université Catholique de Louvain2 个研究点 分布在 1 个国家目标入组 20 人开始时间: 2019年11月27日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
20
试验地点
2
主要终点
Amount of sputum secretion

研究概览

简要总结

This study will investigate the contribution of SIMEOX technology on the effectiveness of bronchial drainage.

This is a crossover study to evaluate the contribution of SIMEOX on the effectiveness of bronchial drainage (verified by the amount of sputum secretions, the rheology of sputum secretions and the subjective sensation of ease of sputum) in patients with cystic fibrosis.

Patients will perform, in randomized order (1) a 30-min session of autogenic drainage, (2) a 30-min session of autogenic drainage with the SIMEOX device. Sputum will be collected during and after the session. The two sessions will be performed with minimum washout time of 24 hours.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 90 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Adults with cystic fibrosis
  • Chronic bronchorrhea, able to expectorate by themselves
  • Hospitalized

排除标准

  • Regular use of SIMEOX,
  • Difficulties in understanding instructions,
  • Severe cardiac comorbidity.

结局指标

主要结局

Amount of sputum secretion

时间窗: 30-min

Total wet weight and dry weight of sputum collected in the 24-h following each intervention will be quantified.

Mucus viscoelasticity

时间窗: 30-min

Change in rheological properties of the sputum before and after each intervention will be analyzed using a rheometer. We will use the Rheomuco (Rheonova) reometer to obtain the differences in elasticity (G'), viscosity (G')' and elastic modulus ratio (tanδ) of the secretions collected before and after each intervention.

Subjective feeling of ease to expectorate

时间窗: 3-min

A Visual Analogue Scale (VAS) will be used to measure subjective feeling of ease of expectoration during each intervention. The visual analogue scale (VAS) is a semi-objective rating system that will be used to quantify the subjective feeling of ease to expectorate. The VAS is represented by a horizontal line marked 0 to 10, where "0" indicates "very easy to expectorate" and "10" indicates "not easy to expectorate at all". The lower the score, the easier it is to expectorate.

次要结局

未报告次要终点

研究者

发起方
Cliniques universitaires Saint-Luc- Université Catholique de Louvain
申办方类型
Other
责任方
Principal Investigator
主要研究者

William Poncin, PT, PhD

Principal Investigator

Cliniques universitaires Saint-Luc- Université Catholique de Louvain

研究点 (2)

Loading locations...

相似试验